A.B.S. FIREKILL 15241 Technical Data Manual
a.b.s. S.r.l. (Milan) ItalyLombardia Street 310, 20861 S.Dam. BrugherioTel. +39 - 039 - 839631 - Fax. +39 - 039 - 8396349e-mail:info@absfire.it www.absfire.it Capital euro 2,000,000.00Technical Bulletin1370Technical data are subject to modificationfor improvements without prior noticeData Sheet Code Date Check Rev Pag.Fire Extinguisher 15241 22/02/15 JC 5/AL 1/3234187 56Installation (illustration 1)The FIREKILL must be hanged to its metal wall bracket inside oroutside the protected area.Check the pressure looking at the pressure gauge the needlemust be in green sector. Fix the pipes (3) from the FIREKILL bodyto the area to be protected, connect the discharge nozzles (1) atthe end of the pipes (3), near the dangerous point or theprotected area.Fix the remote control cable (4) to the hexagon (7) and to theremote control handle (2).Safety pin (5) must be pulled out at the end of all aboveoperations. Now the FIRE KILL is ready to work.FIREKILL can be activated manually by pulling the remote controlhandle (2), otherwise automatically when the bursting temperatureof Sprinkler bulb is reached.Bulb glass can be supplied with bursting temperature at 93 or68°C.The electric actuator (6) can be supplied on request. It can beconnected with an emergency control push button or through acontrol panel in case there is an automatic detection system.A standard detection system for our firekill system is composed by:• Low pressure switch cod. 23024, which directly indicatesalarm leaks or discharging In case of need of the low pressureswitch, please inform the manufacturer before ordering, so wecan mount it before the pressurization process;• Control panel which enable the perfect control of the full systemcod. 23022 or 23022_1 or 23023;• Thermosensitive detectors, cables or candels.The electric actuator is a pyrotechnical charge, 5 years guaranteedat a work temperature from -20°C up to +80°C and humidity of100%. The pyrotechnical charge can work with minimum 12 Vtension and 1 A current.Electrical connection:The electrical connection to the pyrotechnical actuator must bemade by a shielded wire; it must be connected directly from batteryto the emergency push-button (Control Box Cod. 23022, 23022_1or 23023) and to the actuator. Avoid to connect the actuator indifferent positions (like fuses panel) to avoid accidental activations.Torque force:The valve is screwed down to the tank at the prefixed torquebetween 5 and 6 Kg/m (i.e. between 50 and 60 Nm).Illustration 1Description:FIREKILL is an automatic extinguishing system composed by apressurized cylinder filled with POWDER ABC.It is equipped with manual remote control and equipped with athermosensitive bulb, at 93°C (or on request at 68°).It must be equipped with pressure switch to check charge.If the fire extinguisher is located inside the space protected or ifthe activation of the fixed system is automatic, a visual indicationof discharge outside the protected room shall be provided.The visual indication must be chosen by Customerdepending on the detection system specifications.FIREKILL has a versatile valve, completely automatic without useof any source of energy. It has a manual remote control pull cableor on request a remote battery control electric box actuator.Moreover it is possible to connect a control panel that controls thesmoke detectors.FIREKILL unique valve has two outlet diam. 3/8" pipes, a maximumof 4 nozzles, it may distribute the jet with precision in the effectivepoint of the fire risk. Assembly without necessity to thread tubes,extremely easy and quick. Suitable also to protect mixers ofvarnishes, garages, flammable liquids storage, etc.Extinguishing agentDry chemical powder ABC 30% is produced in according to EN615 (1995) and ISO 9001 quality control.The basic components of dry powder are ammonium phosphateand ammonium sulphate with special silicones additives enablingeasy flow discharge and avoiding any checking process.Dry powder is not corrosive, not abrasive, non toxic for humansand animals.Note: other kinds of powder may be used ABC 30% ask ourtechnical office for compatibility.The kit includes following parts:• Steel cylinder CE;• Rapid discharge valve made of chromed brass M30x1,5 withmanometer and thermosensitive bulb at 93°C (5);• Extinguishing agent;• Pipe with fast connection couplings (3);• Discharge nozzles made of chromed brass (1);• Remote control with handle (4+2);• Electric actuator (6) (optional) which connects the remotecontrol to an automatic control panel;• Wall bracket (8);Use:1) Pull the handle (2) in case of fire or2) (If installed) Push the button on the control box to activate thepyro. actuator;3) The temperature higher than sprinkler bulb temperature willactivate the FIREKILL.Operation:The unit is pressurized at 14 bar at 20°C.Mount onlyin vertical position.For horizontal orupsideneed, contactfactory whenorderingFIREKILL SYSTEMS 1-3-6-9-12 kg POWDER ABCRINA APPROVED ISO 9094:2015 No. 525310CS/002- ISO 14520EC certificateCode Charge Protected zone Q.ty nozzle Max pipekg m3 length mt x 215241 1 1.7 2 215227 3 5.1 2 415228 6 10 2 515226 9 15 4 615229 12 20 4 8On request it will be availabe also 2 and 4 kg |
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine