4Indoor passive infrared detectorProduct code 2CSYD0102BTechnical specificationsAPPLICATION SCOPE SecurityCOMMUNICATIONTECHNOLOGYTransmission in FM 868.3 MHzRANGE IN FREE AIR 300 mPOWER SUPPLY Lithium battery 3 V – 1.4 Ah lasting 4years.Operation is guaranteed for 30 days fromthe low battery notificationDETECTION ELEMENTS 1 IR sensor with Fresnel lensPROGRAMMING ELEMENTS 1 jumper for test1 jumper for pulse countingSIGNAL ELEMENTS 1 red LEDLow battery in the control unitANTI-TAMPERING PROTECTION TamperAdditional data provided by the manufacturerUSAGE TEMPERATURE -5 … + 45 °CUSAGE RELATIVE HUMIDITY Max 95% max (non-condensing)USAGE ENVIRONMENT Indoor (sheltered and dry places)INSTALLATION FreeSIZES (L x H x W) 70 x 114 x 76 mmWARNING! Installation must be carried out only by aqualified electricianPackage contentsno. 1 Indoor passive infrared detectorno. 1 Lithium battery 3 V – 1.4 Ahno. 2 Self-tapping cross-recessed screws 2.9 x 27 mmno. 2 Screw anchors ∅ 5 mmno. 1 ManualEC Declaration of ConformityABB S.p.A., with registered office in Milan - via Vittor Pisani 16,declares under its own responsibility that the device with productcode 2CSYD0102B meets the essential electromagneticcompatibility and security requirements contained in the DirectiveR&TTE 1999/5/EC and in the EC Low Voltage Directive2006/95/CE, as it was designed and manufactured in compliancewith the following harmonized standards: EN 300 220, EN 50130-4, EN 50131-1, EN 50131-2-2, EN 50131-5-3.ABB S.p.A. - ABB SACE DivisionViale dell’Industria, 1820010 Vittuone (MI) – ItalyPhone: 02.9034.1Telefax: 02.9034.7609ABB S.p.A. reserve the right tochange the product described inthis manual at any time andwithout any advance notice.For further information:http://bol.it.abb.com, atDomusTech section or call thefree-phone numberPrinted in ItalyManual code 2CSM600503D0201 rev 00InstallationThe installation procedure encompasses the following steps:1) Device fixing.2) Operation settings (wide coverage angle/long-distancecoverage and standard/corridor for \).3) Power supply and programming.4) Completion and test.1. Device fixingINSTRUCTIONS RELEVANT TO POSITIONINGThe device shall be installed:• at a height of 240 cm above the ground or at a height of 90cm in order to create a corridor for pets (standard heights canbe changed);• far from heat sources and from direct sunlight;• far from electromagnetic sources (e.g. electricity meters,electric engines);• at a distance of at least 1.5 meters from fluorescent lights;• by avoiding to direct the detector towards moving objects(e.g. curtains);• by avoiding to direct the detector towards reflecting objectsthat could change the coverage area.Figure 1 shows the IR coverage diagrams in flat view and inheight view (standard settings and corridor settings for pets)when the detector is adjusted for a wide coverage angle.Figure 2 shows similar coverage diagrams related to the detectoradjusted for a long-distance coverage.Figure 1General descriptionThe indoor passive infrared detector detects the presence ofintruders in the controlled area.The detector can be configured in order to provide a widecoverage angle or a long-distance coverage by keeping the samesensitivity.The sensor can operate also in presence of pets.- 1 -Indoor passive infrareddetectorEN Installation manual2CSYD0102B- 2 - - 3 -