ABB Fox 21 Original Instructions Manual
While every effort has been taken to ensure the accuracy of information contained in this book and any associated promotional and information materialJOKAB SAFETY cannot accept responsibility for errors or omissions and reserves the right to make any improvements without notice. It is the usersresponsibility to ensure that this equipment is correctly designed, specified, installed, cared for and operated to meet all applicable local, national andinternational codes/regulations. Technical data in our book is correct to the level of accuracy of Jokab Safety´s test procedures as verified by variousinternational approved bodies. Other information (such as application examples, wiring diagrams, operation or use) is intended solely to illustrate thevarious uses of our products. JOKAB SAFETY does not quarantee or imply that the product when used in accordance with such examples in a parti-cular environment will fulfil any particular safety requirement and does not assume any responsibility or liability for actual use of the product based onthe examples given.2TLC172243M9801, rev AABB AB/Jokab SafetyVarlabergsvägen 11S-434 39 KungsbackaSverigeABB AB/Jokab SafetyBoplatsgatan 3S-213 76 MalmöSverigeABB AB/Jokab SafetyMekanikervägen 6S-564 35 BankerydSverigeABB AB/Jokab SafetyKanalvägen 17S-183 30 TäbySverigeABB AB/Jokab SafetyFältmätargatan 16S-721 35 VästeråsSverigeTechnical dataManufacturerAddress ABB AB / JOKAB SAFETYVarlabergsvägen 11SE-434 39 KungsbackaSwedenArticle number /ordering dataFox21: 2TLJ020160R2100Fox22: 2TLJ020160R2200Fox31: 2TLJ020160R0100Fox32: 2TLJ020160R0200Power supplyRated insulating voltageUi690VSwitching capacity AC-15 220.. 240V, 6A380…440V, 4A500V, 3AConnection cable crosssections single resp.multi-strand1-4 mm 2Fine wire with core endbush(DIN 46228)0.75-2.5 mm 2Terminal screws M4Short circuit protection,fusible cut-out (gL)25A max.Insulation requirementsmet up to480V~Cable entry M20GeneralProtection class IP65Ambient temperature Operation: -15…+60°CMaterial:Safety coverPedalAluminiumShockproof thermoplasticSize See drawingWeight (approx..) withsafety coverFox31: 1.7 kgFox32: 3 kgColour Yellow and blackMechanical lifeNumber of operationsPosition 2: 1x10 6Position 3: 3 x 105Safety / Harmonized StandardsConformity European Machinery Directive 2006/42/ECEN ISO 12100:2010,EN 60204-1:2006+A1:2009,EN ISO 13849-1:2008,EN 60947-5-1:2003+A1:2009EN ISO 13849-1 Performance level: Up to PL c, category 1B 10d: 300 000Certificates BGEC Declaration of conformityDimensionsFox21/31Fox32/22Original instructionsFox – Safety foot operated switchGeneral descriptionThe foot-operated safety switch Fox have been developed for industrial application with high mechanical and electricalendurance. The foot-operated switches are used on wood processing machines, CNC machines, building machines andbending machines. Normally a safety foot operated switch is used when the operator has to have both hands free.Fox is available with a three or two positioning function in single and double pedal variants. Fox is always supplied withduplicated contacts and robust safety cover.Fox 31/32, three position function, provide stop signals in the top and bottom position. Start/ready signals for separatestarting are provided in a distinct middle position. After a stop in the bottom position a start or clear signal cannot be givenbefore the reset knob has been operated and the pedal has been pushed into its middle position.Fox 21/22, two-position function, provide stop signal in the top or pedal released position. A start/ready signal forseparate starting is given in the bottom or fully depressed position.Connection example – FoxWarning! All the safety functions must be tested before starting up the system.System description – three position pedal Fox 31/321) Normal: In resting position, the machine is OFF and the operator is preparing the work piece.2) Operation: By pressing the pedal to the middle position the contacts 23-24 and 43-44 are closed and the safetyrelay is activated. The machine is running.3) E-Stop: If danger occurs the operator press the pedal to the third (bottom) position. A stop signal is immediatelysent to the machine. The safety relay falls and the machine stops. NB! Only available on Fox 31 and Fox 32.4) Reset: After reaching the third position the pedal is locked and must be reset by turning the knob 90° counterclockwise by hand, thereby releasing the latch.5) Normal: The pedal is now in its stand-by position again, ready for next operation.MaintenanceWarning!The safety functions and the mechanics shall be tested regularly, at least once every year to confirm that all the safetyfunctions are working properly.In case of breakdown or damage to the product, contact the nearest ABB/Jokab Safety Service Office or reseller. Do nottry to repair the product yourself since it may accidentally cause permanent damage to the product, impairing the safety ofthe device which in turn could lead to serious injury to personnel.B) Pedal Fox21 with safety module RT9A) Pedal Fox31 with safety module RT6Version contact configuration:1) Pedal2) Contact point3) Lockout reset knob |
Related manuals for ABB Fox 21
ABB MKey8M Original Instructions Manual
ABB vital 1 Original Instructions Manual
ABB Sense7 Series Original Instructions Manual
ABB Sense 7 Series Original Instructions Manual
ABB LineStrong2 Series Original Instructions Manual
ABB JSTD20 Instructions For Use Manual
ABB F-400 Installation Instructions Manual
ABB RS85 Operating Instructions Manual
ABB ZX1.5-R Instruction Manual
ABB MS40/EX Operating Instructions Manual
manualsdatabase
Your AI-powered manual search engine