—I N S TA L L AT I O N M A N U A LStanilite®Platinum Spitfire® LED recessedNexus® RFDoc no. 29-WSIS001_AThis document covers What’s inside the boxSafety warning Lamp head assemblyInstallation instructions Battery and control packRemoval instructions Accessory kitTesting precautions Installation manualTroubleshooting guide Warranty informationTroubleshooting guideIf you have installed and connected the fitting as per the instructions listed earlier and it doesnot function correctly, use the following table as a guide to fixing the problem. Look up thetype of fault in the left column and check the possible causes from the right column.If the fitting still does not work after checking these possible causes, contact ABB customerservice in Australia on 1800 60 20 20.—ABB Australia Pty LimitedFor enquiriesABB contact centre: 1800 60 20 20E-mail: AU-ABB-Stanilite@abb.comwww.stanilite.com.au © Copyright 2019 ABB. All rights reserved.9AKK1074920280 - A - May 2019Thank you for choosing ABB productPlease read this document thoroughly beforecommencing installation and retain for futurereference. Contact ABB customer service inAustralia on 1800 60 20 20 if you need anyassistance. The installation instructions werecorrect at the time of print. To reflect changes intechnology and Australian standards; ABBreserves the right to amend the instructionswithout notice. Updated document can be foundon the Stanilite website.Safety warningIn Australia and New Zealand, only licensedelectricians are permitted by law to work with240 volt electrical installations.Do not attempt to install or connect this productunless you are a licensed electrician.Turn off and isolate the electrical supply beforeconnecting this fitting to the building wires.Do not touch the terminals of the terminal blockwhen the light fitting is energised.The only user-serviceable parts are the lamp headassembly and battery pack. LED light source isnot user-serviceable.Do not attempt to service other parts of theNo. Fault Possible causes1 LED light source and indicating LED not lit AC supply not connected; orAC supply turned off; orTest switch damaged2 LED light source is lit but indicating LED not lit Test switch damaged; orBattery not connected or faulty3 LED light source does not switch to emergencymode when the test button is pressedTest switch damaged; orBattery not connected or faulty4 LED light source works momentarily on emergencywhen the test button is pressedBattery not yet charged (allow up to 24 hours)fitting as this will void the warranty.As the installer, it is your responsibility to ensurecompliance with all relevant building and safetycodes, (ie: AS/NZS 3000, AS/NZS 2293). Refer tothe applicable standards for data and mainscabling installation procedures andrequirements.As per AS 60598.2.2:2016 the recessed luminaireclassification is CA90.Note: Not suitable for use with loose-fillinsulation.The control pack and battery pack must beinstalled above the insulation. No fire rated box isrequired for the product.Important to note:• This product is designed for indoor use only.Nexus RF (wireless system)The Nexus RF range of light fittings are designed tocommunicate via a proprietary RF network, howeverthe electrical installation of the fittings is identicalto that of a standard non-monitored fitting.