—I N S TA L L AT I O N M A N U A LStanilite®Platinum exit LED edgelit surface mountDALI emergencyDoc no. 29-01166_1This document covers What’s inside the boxSafety warning Surface mount baseassemblyInstallation instructions Diffuser assemblyRemoval instructions Surface mount base coverTesting precautions Pictograph insert packTroubleshooting guide Installation manualWarranty informationTroubleshooting guideIf you have installed and connected the fitting as per the instructions listed earlier and it doesnot function correctly, use the following table as a guide to fixing the problem. Look up thetype of fault in the left column and check the possible causes from the right column.If the fitting still does not work after checking these possible causes, contact ABB customerservice in Australia on 1800 60 20 20.—ABB Australia Pty LimitedFor enquiriesABB contact centre: 1800 60 20 20E-mail: AU-ABB-Stanilite@abb.comwww.stanilite.com.au © Copyright 2020 ABB. All rights reserved.9AKK107046A0981 - A - Feb 2020No. Fault Possible causes1 LED lamp and indicator LED not lit AC supply not connected; orAC supply turned off2 LED lamp not lit but red indicator is lit LED lamp damaged; orLED lamp plug incorrectly inserted in the mother board3 LED lamp not lit but indicator LED is flashing green LED lamp damaged; orLED lamp plug incorrectly inserted in the mother board4 LED lamp is lit but red indicator LED not lit LED damaged; orCheck battery connection5 The LED lamp does not switch to emergency modewhen the test button is pressedTest switch damaged6 Indicator LED is constant green Test switch damaged; orSelf check fail - return to factory7 Indicator LED not red after commissioning Check battery connection and battery plug polarity8 The LED lamp works momentarily on emergencywhen the test button is pressedBattery not yet charged (allow up to 24 hours)Thank you for choosing ABB productPlease read this document thoroughly beforecommencing installation and retain for futurereference. Contact ABB customer service inAustralia on 1800 60 20 20 if you need anyassistance. The installation instructions werecorrect at the time of print. To reflect changes intechnology and Australian standards; ABBreserves the right to amend the instructionswithout notice. Updated document can be foundon the Stanilite website.Safety warningIn Australia and New Zealand, only licensedelectricians are permitted by law to work with240 volt electrical installations.Do not attempt to install or connect this productunless you are a licensed electrician.Turn off and isolate the electrical supply beforeconnecting this fitting to the building wires.Do not touch the terminals of the terminal blockwhen the light fitting is energised.The only user-serviceable part is the batterypack. LED light source is not user-serviceable.Do not attempt to service other parts of thefitting as this will void the warranty.As the installer, it is your responsibility to ensurecompliance with all relevant building and safetycodes, (ie: AS/NZS 3000, AS/NZS 2293). Refer tothe applicable standards for data and mainscabling installation procedures andrequirements.DALI (Digital Addressable Lighting Interface)DALI is widely acknowledged as being an openprotocol as defined under IEC 62386 and isdesigned only for communication in lightingsystems.ABB exit and emergency luminaire with DALIfunctionality comply with DALI standard IEC62386.The DALI edgelit surface mount wiring consistsof additional 2 way terminal block in the baselabelled as + and - for DALI control wires apartfrom the mains terminals, ie: USA, N and E.Note: No mains or mains carrying cables are tobe connected to DALI terminals or 2 controlwires (white and black).Important to note:• This product is designed for indoor use only.