ACF GreenHouse SureSTAT TS200 Operating Instructions Manual
General Safety InformationDisconnect all powerbefore installing orservicing this product. If the powerdisconnect is out of view, lock it in theopen position and tag it to preventunexpected restarting of power. Failure todo so could result in fatal electric shock.1. Special attention must be given to anygrounding information on this productand to other equipment associated withits installation and use. To ensure aproper ground, the grounding meansmust be checked by a qualifiedelectrician.2. Be certain that the electrical ratings ofthe thermostat conform to the powersource and the load(s) being controlled.Loads that exceed the rating of thethermostat should be handled with asuitable rated relay or motor starter.Do not depend uponthe thermostat as thesole means of disconnecting power wheninstalling or servicing the product it iscontrolling. Always disconnect powerat the main circuit breaker as describedabove. Failure to do so could resultin fatal electric shock.3. This thermostat is intended ONLY forpermanent installation in accordancewith the United States NationalElectrical Code (NEC), all applicablelocal codes and ordinances, and allsections of this manual. All wiringshould be done by a qualifiedelectrician, using copper wire only.These thermostatsare intended forgeneral heating, ventilating, andrefrigeration ONLY. They must NOT beused in potentially dangerous locationssuch as flammable, explosive, chemicalladen areas.These thermostatsare designed for useas operating controls only. Where anoperating control failure would result inpersonal injury and/or loss of property, itis the responsibility of the installer to adddevices (safety, limit controls) or systems(supervisory alarm systems) that protectagainst, or warn of control failure.In cases wherepersonal injuryor property damage may result frommalfunction of the thermostat, a backupsystem must be used. Where critical orhigh value products are maintained, anapproved temperature limit should bewired in series with this thermostat.In less critical applications, a secondthermostat with alarm contacts maybe used for redundancy.InstallationLOCATIONMount this product 5 to 6 feet (1.5 to1.8 m) above the floor so it will beexposed to the average temperatureof the controlled space. Do not mountcontrol where it could be affected byunusual heat or cold such as in sunlightor beside equipment. Avoid locations neara door, window or other opening. Donot mount on an outside wall. When thethermostat is mounted with coil pointeddown, it is protected from falling objects,dirt, and debris.MOUNTING – FIXED INSTALLATIONSFour mounting holes for fixed installa-tions are found in the back of the case.On rough surfaces use the top mountingholes only. When mounting this controlon uneven surfaces, when all fourmounting screws are tightened, thehousing may deform enough to affectthe thermostat calibration and operation.Do not dent or deformthe sensor coil ofthis control. A dent or deformationwill change the calibration and causethe control to cycle at a temperaturelower than the knob setting.HOW MODELS WITH AN ADJUSTABLEDIFFERENTIAL OPERATEIncreased differentialsubtracts from thetemperature setting. For example, if theknob is set to 50°F, and the differentialis set to MAX, a heater would turn onat approximately 35°F. For cooling, thedevice would turn ON at 50°F, and OFFat approximately 35°F.Form PN10541 Printed in ChinaSureSTAT ThermostatsOperating InstructionsPlease read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protectyourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage!Retain instructions for future reference.DescriptionThese thermostats are designed for reliable heating and cooling applications. Theyare made with high strength NEMA 4X rated plastic enclosures and may be mountedindoors or outdoors. These models are protected from rain and may be washed downwith a hose but must not be exposed to standing water or be submerged.Model TS110 – Single stage hard-wired thermostatModel TS200 – Two stage (3°F differential between stages) hard-wired thermostatTemperature Range: 30° to 110°FDifferential: 3°F fixedElectrical Rating: Millivolt to 120 VACMaximum Electric Load: 16 amps at 120 VACGARANTIA LIMITADAGARANTIA LIMITADA DE SURESTAT POR UN AÑO. SURESTAT LE GARANTIZA AL USUARIO ORIGINAL QUE LOSMODELOS TRATADOS EN ESTE MANUAL DE LOS TERMOSTATOS DE VOLTAJE DE LÍNEA SURESTAT ESTAN LIBRES DEDEFECTOS EN LA MANO DE OBRA O EL MATERIAL, CUANDO SE LES SOMETE A USO NORMAL, POR UN AÑO A PARTIRDE LA FECHA DE COMPRA. CUALQUIER PARTE QUE SE HALLE DEFECTUOSA, YA SEA EN EL MATERIAL O EN LA MANODE OBRA, Y SEA DEVUELTA (CON LOS COSTOS DE ENVIO PAGADOS POR ADELANTADO) A UN CENTRO DE SERVICIOAUTORIZADO DESIGNADO POR SURESTAT, SERA REPARADA O REEMPLAZADA (NO EXISTE OTRA POSIBILIDAD)SEGUN LO DETERMINE SURESTAT. PARA OBTENER INFORMACION SOBRE LOS PROCEDIMIENTOS DE RECLAMOCUBIERTOS EN LA GARANTIA LIMITADA, VEA LA SECCION “ATENCION OPORTUNA” QUE APARECE MAS ADELANTE.ESTA GARANTIA LIMITADA CONFIERE AL COMPRADOR DERECHOS LEGALES ESPECIFICOS QUE VARIAN DEJURISDICCION A JURISDICCION.LIMITES DE RESPONSABILIDAD. EN LA MEDIDA EN QUE LAS LEYES APLICABLES LO PERMITAN, LARESPONSABILIDAD DE SURESTAT POR LOS DAÑOS EMERGENTES O INCIDENTALES ESTA EXPRESAMENTE EXCLUIDA.LA RESPONSABILIDAD DE SURESTAT EXPRESAMENTE ESTA LIMITADA Y NO PUEDE EXCEDER EL PRECIO DE COMPRAPAGADO POR EL ARTICULO.EXCLUSION DE RESPONSABILIDAD DE LA GARANTIA. SE HAN HECHO ESFUERZOS DILIGENTES PARAPROPORCIONAR INFORMACION E ILUSTRACIONES APROPIADAS SOBRE EL PRODUCTO EN ESTE MANUAL; SINEMBARGO, ESTA INFORMACION Y LAS ILUSTRACIONES TIENEN COMO UNICO PROPOSITO LA IDENTIFICACION DELPRODUCTO Y NO EXPRESAN NI IMPLICAN GARANTIA DE QUE LOS PRODUCTOS SEAN VENDIBLES O ADECUADOSPARA UN PROPOSITO EN PARTICULAR NI QUE SE AJUSTAN NECESARIAMENTE A LAS ILUSTRACIONES ODESCRIPCIONES. CON EXCEPCION DE LO QUE SE ESTABLECE A CONTINUACION, SURESTAT NO HACE NI AUTORIZANINGUNA GARANTIA O AFIRMACION DE HECHO, EXPRESA O IMPLICITA, QUE NO SEA ESTIPULADA EN LA“GARANTIA LIMITADA” ANTERIOR.Consejo Técnico y Recomendaciones, Exclusiones de Responsabilidad. A pesar de las prácticas, negociacioneso usos comerciales realizados previamente, las ventas no deberán incluir el suministro de consejo técnico o asistenciao diseño del sistema. SureSTAT no asume ninguna obligación o responsabilidad por recomendaciones, opiniones oconsejos no autorizados sobre la elección, instalación o uso de los productos.Adaptación del Producto. Muchas jurisdicciones tienen códigos o regulaciones que rigen la venta, la construcción,la instalación y/o el uso de productos para ciertos propósitos que pueden variar con respecto a los aplicables a laszonas vecinas. Si bien se trata de que los productos SureSTAT cumplan con dichos códigos, no se puede garantizar suconformidad y no se puede hacer responsable por la forma en que se instale o use su producto. Antes de comprar yusar el producto, revise su aplicación y todos los códigos y regulaciones nacionales y locales aplicables y asegúresede que el producto, la instalación y el uso los cumplan.Ciertos aspectos de limitación de responsabilidad no se aplican a productos al consumidor; es decir (a) algunasjurisdicciones no permiten la exclusión ni limitación de daños incidentales o consecuentes, de modo que laslimitaciones o exclusiones anteriores quizás no apliquen en su caso; (b) asimismo, algunas jurisdicciones no permitenlimitar el plazo de una garantía implícita, por lo tanto, la limitación anterior quizás no aplique en su caso; y (c) porley, mientras la Garantía Limitada esté vigente no podrán excluirse ni limitarse en modo alguno ninguna garantíaimplícita de comercialización o de idoneidad para un propósito en particular aplicables a los productos al consumidoradquiridos por éste.Atención Oportuna. Se hará un esfuerzo de buena fe para corregir puntualmente, o hacer otros ajustes, conrespecto a cualquier producto que resulte defectuoso dentro de los términos de esta garantía limitada. En el casode que encuentre un producto defectuoso y que esté cubierto dentro de los límites de esta garantía haga el favorde escribir primero, o llame, al distribuidor a quien le compró el producto. Para cualquier producto que crea queestá defectuoso según la garantía limitada, póngase en contacto con:Síntoma Causa(s) Posible(s) Medida CorrectivaEnfriamiento:El ventilador o el sistema deenfriamiento no funcionaEl ventilador o el sistemade enfriamiento funcionacontinuamenteEl sistema funciona enforma inversaCalefacción:La unidad de calefacciónno funcionaLa unidad de calefacciónfunciona continuamenteEl sistema funciona enforma inversa1. Cableado inadecuado2. La perilla está dispuesta por encimade la temperatura ambiente1. Cableado inadecuado2. La perilla está dispuesta por debajode la temperatura ambienteCableado inadecuado1. Cableado inadecuado2. La perilla está dispuesta por debajode la temperatura ambiente1. Cableado inadecuado2. La perilla está dispuesta por encimade la temperatura ambienteCableado inadecuado1. Revise el cableado2. Ajuste la perilla a unatemperatura más baja1. Revise el cableado2. Ajuste la perilla a unatemperatura más altaRevise el cableado1. Revise el cableado2. Ajuste la perilla a unatemperatura más alta1. Revise el cableado2. Ajuste la perilla a unatemperatura más bajaRevise el cableadoTabla de Identificación de ProblemasInstalación (Continuación)2. Cuando los termostatos se encuentranconectados a un sistema o dispositivo deCalentamiento: Gire la perilla hacia la derechaa una posición por encima de la temperaturaambiente; la unidad de calefacción deberáestar activada. Cuando se gira la perilla haciala izquierda (a un ajuste de temperaturamás baja), la unidad de calefacción deberáapagarse aproximadamente en la posiciónde ajuste de la perilla.3. Termostatos con interrupción SPDT/SPDTde 2 etapas: Si la conexión es similar a laFigura 4, el ventilador deberá activarse aaproximadamente la temperatura ambientey deberá cambiar a alta velocidad, al girarsela perilla hacia la izquierda a un ajuste detemperatura más baja. Si el cableado essimilar a la Figura 5, el moderador deberáabrirse al girarse la perilla hacia la izquierda(a un ajuste de temperatura más baja). Losdispositivos deberán funcionar en lasecuencia inversa cuando se gira laperilla hacia la derecha.OperaciónLa Figura 8, página 3 muestra el funcionamientode termostatos con interrupción SPDT/ SPDTde 2 etapas. Si la temperatura aumenta conrespecto al ajuste de la perilla, el circuito entreR e Y del interruptor de etapa baja (RYL) secierra. Simultáneamente, el circuito entreR y B (RBL) se abre.Si la temperatura aumenta más, el interruptorde etapa alta funciona y cierra (RYH) mientrasabre simultáneamente (RBH). Se produce lasecuencia inversa si la temperatura desciende.AVISO: No hay partes de repuesto disponibles.No intente realizar ninguna reparaciónen campo.380 Greenhouse DriveBuffalo Junction, VA 245291-888-888-9050 |
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine