ACME DM Series Installation Manual
INSTALLATION MANUALDIN Rail Power Supplies, Plastic Single PhaseSAFETY ALERT FOR YOUR SAFETY, READ ALL INSTRUCTIONS BEFORE INSTALLATION AND OPERATION.NOTICE: Products are not to be used nor are warranted in aerospace, nuclear, medical patient connect, or lifesafety applications.This manual is subject to change without prior notice.Safety Instructions WARNING – Avoid Possible Injury or DeathWARNING: Never work on the power supply when power is applied. Electric shock and arc risks can cause death, severe personalinjury or substantial property damage. Power source must be off and properly secured before any installation, maintenance or modificationwork is completed. Keep away from fire and water. Before installing unit, thoroughly read these instructions.1. As a reminder, these products are not to be installed in nuclear or medical (patient connect) applications. Units are only to be installed byprofessionals. Only professionally trained personnel may open the power supply. If you have any questions concerning theinstallation or operation of this equipment, please call the number located at the front of this document.2. The units meet the safety requirements of UL508, UL60950-1, IEC/EN60950. They are approved in accordance with EN60950, UL508,(TUV) EN55022, EN55024, CE MARKING and meet the requirements EMC and the Low Voltage Directive.3. These units must always be installed with any national, county or city regulations that apply. Connections to mains supply must be incompliance with national and city regulations. Power supply and main cables must be sufficiently fused in accordance with local codes.Follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary, and it isyour responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are incompliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result by not following allapplicable standards and codes. We do not guarantee the products described in this publication are suitable for your particularapplication, nor do we assume any responsibility for your product design, installation, or operation.4. Sufficient temperature and cooling and space clearances must be ensured as indicated: Operation requires no external cooling butrequires minimum clearances on top, bottom, and sides of units. Refer to installation Cooling and Airflow Requirements below5. Avoid potential danger of contact with case by ensuring all strands of stranded wire use (if applicable) are fastened in the terminal blocks.6. SAFETY ALERT Hazardous voltages and components storing a substantial amount of energy are present in this unit during normaloperating conditions. Improper handling may result in electric shock or serious burns.7. WARNING Do not open the power supply until at least 5 minutes after it has been disconnected from the mains on all poles.8. Do not introduce any objects into the power supply. The output voltage adjustment potentiometer may only be actuated usingan insulated screwdriver.Installation Instructions WARNING – Avoid Personal Injury or Product Damage.1. Read and follow all instructions before installation as indicated in this manual. This publication is based on information that wasavailable at the time it was printed. We reserve the right to make changes to the products and/or publications at any time without noticeand without obligation.2. DIN Rail Connection; as per local electrical codes and recommended wire sizes.3. DIN Rail mounted per VDE0160 Please see diagram as noted below.4. This power supply is designed for professional indoor systems. During operation the power supply must not be accessible. Install and putinto service by qualified personnel only.5. Do not operate without Protective Earth (PE) connection! To comply with EMC and safety standards (CE mark, approvals) the powersupply must be operated only if PE terminal is connected to the non-fused earth conductor.6. Do not cover any ventilation holes. The correct mounting position for optimal cooling performance must be observed. All free spacerequirements and power de-rating as specified at the beginning of this manual must be observed.7. WARNING The internal fire safety fuse is not accessible. This fuse is not to be replaced by the user. For continued protectionagainst risk of fire, NO REPLACEMENT OF FUSE IS ALLOWED REGARDLESS. If this internal fuse has blown, the power supply hasa serious internal defect, and for safety reasons, must be discarded, or if under warranty, returned.8. Please ensure that the power supply will be recycled properly at the end of its life. Some components of this power supply may besuitable for recycling, including some that require special disposal. |
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine