ACTpro 1010Reader (Exit)Wire both readers in parallel but leavethe SENSE line on the Exit reader unconnected.ControllerSENSECLOCKDATA+5v0vREDGREENCard/Prox ReaderWhiteGreenBlueRedBlackBrownYellowOrangeSENSECLOCKDATA+5V0VREDGREENNot ConnectedWiring for Clock and DataThe +5V reader supply on ACT controllers is normally ratedat 100mA. Typically this is sufficient to power 2 ACT readers.Note however that readers from other manufacturers may needto be powered separately if their current requirements exceedthis or if they require 12V.The standard wiring colours forACTpro 1010 reader is shown above.Readers should be a maximum of 30mfrom the controller when poweredfrom +5V and a maximum of 100mwhen powered from +12V.Unit C1, South City Business Centre, Tallaght, Dublin 24, Ireland.Telephone: 353 1 466 2570. Telefax: 353 1 452 0427. E-mail: sales@accesscontrol.ie Web: www.accesscontrol.ieACTpro 1010 Wiring for Entry / ExitACTpro 1010Reader (Entry)The ACTpro 1010 is configured to read ISO Track 2 of magnetic stripe card media.Reader SpecificationVoltage: 5-12V DCCurrent: 15 mA standby, 20 mA maximumOperating Temperature: -10 degrees C to +55 degrees CMedia: ISO standard high or low coercivity magnetic cardSpeed: 12.7-172 cm/sHead Life >1,000,000 passesCable: 3m x 8-core screenedReader Distance: Max 30m from controller powered with 5V DCMax 100m from controller powered with 12V DC18-0004 Issue 4