Abrams StarEye Series Installation And Operation Manual
Also see for B-S1200: Installation and operation guide
2013 BInstallation and Operation GuideIMPORTANT: Please read all of the following instructions before installing your new StarEye LED Beacon Series.WARNING!!!! Failure to install or use this product according to manufacturer’s recommendations may result in property damage, serious injury, and/ordeath to those you seek to protect!Flash Patterns:P1.Single Flash 75 FPM Phase 1 (SIM) – syncP3.Single Flash Rotator 75 FPMP5.Single Flash 120 FPM Phase 1 (SIM) – syncP7.Single Flash Rotator 120 FPMP9.Single Flash 375 FPM Phase 1 (SIM) – syncP11.Single Flash Rotator 375 FPMP13.Double Flash 75 FPM Phase 2 (SIM) - syncP15.Double Flash 130 FPM Phase 2 (SIM) – syncP17.Triple Flash 130 FPM Phase 1 (SIM) - syncP19.Quad Flash 75 FPM Phase 1 (SIM) - syncP21.Quad Flash Rotator 75 FPMP23.ECE R65 Rotator Flash 60P25.CA T13 Double Flash 75FPM (SIM)P27. ModuFlash sim.P29.Steady Burn*sync means that pattern has synchronized function*Phase OperationPhase 1 (Ph1) flashes simultaneously with Ph1Phase 2 (Ph2) flashes simultaneously with Ph2Ph1 alternates with Ph2Inspect the contents to be certain that the following items are included:A- LED Beacon B- Manual C- Hardware KitWiring:Red: Positive +10〜30VDC (need to add 3A Fuse)Black: NegativeBlue: Pattern SwitchYellow: Synchronized Function* Synchronize Feature: Maximum of8 Beacon can be synchronized*DUAL SWITCH PLUG (3A FUSE INSIDE):*The One switch have LED is power on/off switch*Another switch is pattern switch*Input wire: 4C CableNote: The PLUG types are not synchronizedFunction:Apply BLUE to BLACK wire or Push Pattern Switch- Less than 1 sec. for next pattern- Between 1〜 3 sec. for previous pattern- Between 3〜 5 sec. for factory default- More than 5 sec. for turn off*Proper installation of this product requires the installer to have a good understanding of automotive electronics, systems and procedures.*This product contains high-intensity LEDs. Do not stare directly into these lights. Momentary blindness and/or eye damage could result.*Use only soap and water to clean the outer lens.*Do not install this product or route any wires in the deployment area of your air bag. Equipment mounted or located in the air bag deployment area willdamage or reduce the effectiveness of the air bag, or become a projectile that could cause serious personal injury or death. Refer to your vehicle owner manualfor the air bag deployment area. The User/Installer assumes full responsibility to determine proper mounting location, based on providing ultimate safety toall passengers inside the vehicle.*If mounting this product requires drilling holes, the installer must be sure that no vehicle components or other vital parts could be damaged by the drillingprocess. Check both sides of the mounting surface before drilling begins. Also de-burr any holes and remove any metal shards or remnants. Install grommetsinto all wire passage holes.*Inspect and operate this product regularly to confirm its proper operation and mounting condition. Do not use a pressure washer to clean this product.*For this product to operate at optimum efficiency, a good electrical connection to chassis ground must be made. The recommended procedure requires theproduct ground wire to be connected directly to the NEGATIVE (-) battery post.*It is recommended that these instructions be stored in a safe place and referred to when performing maintenance and/or reinstallation of this product.*FAILURE TO FOLLOW THESE SAFETY PRECAUTIONS AND INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT OR VEHICLEAND/OR SERIOUS INJURY TO YOU AND YOUR PASSENGERS!If this product uses a remote device to activate or control this product, make sure that this control is located in an area that allows both thevehicle and the control to be operated safely in any driving condition.Do not attempt to activate or control this device in a hazardous driving situation.DimensionsT. 844.9.ABRAMSE. info@Abrams-MFG.comW. www.Abrams-MFG.comStarEye SeriesModel B-S1200Recommend Operation EnvironmentAmbient Temperature: -30 to 50℃ Relative Humidity: 10 to 85% , non-condensingTroubleshootingThe StarEye LED Beacon series have been factory tested and approved. If the functions of LED Beacon fail, please checkthe following:1. After connecting with the power supply, be sure that the power source end is joined in a correct way. And then, make surethat there is no short-circuited power occurring.2. Ensure Power switch is turned to "ON" position.3. Press the Function Switch to be sure the “OFF” pattern is not selected .If the blue wire touches black wire over 5 seconds,it would switch to OFF pattern. It would be lighted up again when using blue wire touches black wire over 1 second.4. Determine the Plug fuse is not broken.Warranty (5 Year Warranty)This product was tested and found to be operational at the time of manufacture. Provided this product isinstalled and operated in accordance with the manufacturer’s recommendations, Abrams guarantees the EdgeSeries Light for a period of 5 years from the day of purchase or delivery, whichever is later. Unitsdemonstrated to be defective within the warranty period will be replaced. Improper installation or use ofinappropriate or inadequate wiring or circuit protection causes the warranty to be void. Failure or destructionof the product resulting from abuse or unusual use and/or accidents is not covered by this warranty. Abramsshall in no way be liable for other damages including consequential, indirect or special damages whether lossis due to negligence or breach of warranty.ABRAMS MAKES NO OTHER EXPRESS OR IMPLIED WARRANTY INCLUDING, WITHOUTLIMITATION, WARRANTIES OF FITNESS OR MERCHANTABILITY, WITH RESPECT THISPRODUCT.P2.Single Flash 75 FPM Phase 2 (SIM) – syncP4.Single Flash Rotator 100 FPMP6.Single Flash 120 FPM Phase 2 (SIM) –syncP8.Single Flash Rotator 150 FPMP10.Single Flash 375 FPM Phase 2 (SIM) – syncP12.Double Flash 75 FPM Phase 1 (SIM) – syncP14.Double Flash 130 FPM Phase 1 (SIM) - syncP16.Double Flash Rotator 130 FPMP18.Triple Flash 130 FPM Phase 2 (SIM) - syncP20.Quad Flash 75 FPM Phase 2 (SIM) - syncP22.ECE R65 Rotator Flash 120P24.CA T13 Single Flash 75FPM (SIM)P26.NFPA-Quad Flash 75FPM (SIM)P28.Autorun (Random)P30.OFF |
Related manuals for Abrams B-S1200
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine