1MID:COM 8000MULTI-PRODUCT SINGLE METER CALIBRATION INSTRUCTIONSIt is imperative that the following instructions be very carefully observed. If wefollow the instructions as indicated, your system will be able to resume normaloperation when the calibration adjustments have been completed.The only tools required are a standard flat head screw driver, and a very small flat headscrew driver (jewelry style or equal). And a trouble light to see the switch settings insidethe register.SECTION ONE1. We want the vehicle started and the MID:COM computer in the cab on its“normal” pre-delivery screen. Select “GASOLINE” from line two on thecomputer.2. Then we want to remove the register calibrator cover located on the front of theregister just below the display (2 slotted screws). On the back of this plate youwill find a detailed diagram like the one attached, and a detailed listing of whatthe different switches are used for.3. We have now exposed the calibration switches, (see attached diagram) theseare numbered from your left to your right 1 through 8 as you are looking at theregisters display.4. Making double sure the computer in the cab of your truck is on “GASOLINE” .5. With the very small slotted screw driver and the trouble light (so you can clearlysee the small arrows on the switches) we want to set the following switchesto the following positions (point the little arrows to the following numbers).Switch # 1 to Position 0Switch # 2 to Position 4Switch # 3 to Position 5Switch # 4 to Position 8Switches 5 & 6 do not require changes.