Accurex Temperature Interlock Installation, Operation And Maintenance Manual
Product SpecificationTemperature InterlockInternational Mechanical Code (IMC) 2015 Section507.1.1 compliant electrical package.Provide Accurex, LLC temperature interlock electricalpackage as shown on plans and in accordance with thefollowing specification:The temperature interlock(s) consists of a time delayrelay, adjustable thermostat, junction box, fire proof/leak proof threaded fitting (Evergreen Quik-Seal® and/or Evergreen Compression Seal), and shall be a self-contained unit or as part of another pre-engineeredelectrical control package.The temperature interlock package shall close a timedelay relay powering the fans when the set temperatureis reached at the thermostat. The interlock shall hold thecircuit closed upon fan switch being turned off until thetemperature at the sensor decreases below the set pointat which point the timed relay will begin a countdown.Once the countdown has expired and as long as thetemperature has remained below the set point, the fansshall shut down.The temperature interlock package shall be constructedby Accurex, LLC and operate in accordance withInternational Mechanical Code.Due to continuous research, Accurex, LLC reserves theright to change specifications without notice.WARNINGElectrical shock hazard. Can cause equipmentdamage, personal injury or death. Service must onlybe performed by personal that are knowledgeable inthe operation of the equipment being controlled.CAUTIONAlways disconnect power before working on or nearthe product. Lock and tag the disconnect switch orbreaker to prevent accidental power up.CAUTIONIt is the responsibility of the installer to make sure bothelectrical and gas appliances shut down in the eventof a fire or in the event of a power loss to the buildingwhen this sequence is required by the authority havingjurisdiction.General Safety InformationOnly qualified personal should install this product.Personnel should have a clear understanding of theseinstructions and should be aware of general safetyprecautions. Improper installation can result in electricshock and other potential hazards.1. Follow all local electrical and safety codes, as well asthe National Electrical Code (NEC) and latest editionof the National Fire Protection Agency Standard forVentilation Control and Fire Protection of CommercialCooking Operations (NFPA 96). Follow the CanadianElectrical Code (CEC) and ULC-S650 if installing thisproduct in Canada.2. Do not allow the electrical components of thisproduct to come in contact with oil, grease, hotsurfaces, water, or chemicals.3. Verify the site can supply the necessary power foreach fan and for the control panel.Temperature Interlock 1Installation, Operation and Maintenance ManualPlease read and save these instructions for future reference. Read carefully before attempting to assemble, install,operate or maintain the product described. Protect yourself and others by observing all safety information. Failureto comply with these instructions will result in voiding of the product warranty and may result in personal injuryand/or property damage.Document 473592Temperature Interlock |
Related manuals for Accurex Temperature Interlock
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine