Accutrol AFM5000 Quick Start Manual
Also see for AVC5000: Installation & operation manual
1Quick Start GuideAFM5000 Air Flow Monitor for AVC5000 Controller Covers Models: AFM5000‐xxx & AFM5001‐xxxThis Quick Start Guide provides the basic steps requiredfor the installation, wiring and start-up of the AFM5000and the AFM5001 Air Flow Monitors, when used with theAccuValve AVC5000 controller. For details, refer to theindividual product Submittal Drawings, User Manuals andJob-Specific Requirements.APPLICATIONThe AFM5000 connects directly to theAccuValve AVC5000 control module andgives the user a local Airflow VolumeDisplay and Alarm Indication. TheAFM5000 also gives the user the abilityto “plug in” to the AVC5000 controllerremotely to monitor and adjust theAVC5000 using Accutrol’s Insight UserInterface from a convenient location.The AFM5000 can also be provided witha set point adjustment dial to change theairflow set point in the AVC controller.WIRINGRoute the Monitor Cable from the back of the electrical box tothe location of the AVC5000 control enclosure and insert theMonitor Cable into the Monitor Cable receptacle. Anchor thecable to the strain relief with a cable tie.For applications using the AFM5001, the yellow pig tail on theMonitor Cable is connected to AI-1 (+). The jumper for AI-1 isset to “R” to configure the input.INSTALLATIONThe AFM5000 is designed to be installed into a single-gangelectrical box, with the minimum internal dimensions of 3.825”Hx 2.35”W to accommodate the set point adjustment knob on theAFM5001 and the additional wires.Once the properly sized box isinstalled, route the Monitor Cableinto the electrical box and use astrain relief to prevent the cablefrom being damaged. In the casewhere an AFM5001 is installed,connect the yellow pigtail on theend of the cable with a wire nutto the yellow wire that extendsfrom the back of the displaymodule.Secure the AFC5000 to theelectrical box using the twoscrews provided.Connections to the AVC5000 Control Module will varydepending on the application requirements. The diagrambelow is provided as a general reference only. For detailedwiring requirements, refer to the job specific submittal wiringdiagrams and AVC5000 Manual.START UPBefore proceeding with start-up, verify the followingitems have been completed: All installation has been completed and verified. All wiring has been completed and verified. Power is present at the AVC5000 and verified to spec. System is operating with static pressure control. The configuration PC has Insight loaded and operational.AFM QUICK START GUIDE—NOVEMBER 2015www.accutrolllc.comWIRING DETAIL for AFM5001‐XXX |
Related manuals for Accutrol AVC5000
manualsdatabase
Your AI-powered manual search engine