Baldor VS1SP Installation And Operation Manual
Also see for VS1SP: Quick start guide
VS1SPAnalog I/OJumper SettingsControl Circuit BoardRelay outputsType Function InternalsupplyActivehighJP6JP1J1 J2 J3P3JP3JP3JP2ENPENPEPNEPNEPNEPNEPNDFTDFTDFTDFTDFTINPINPINPINPINPENPENPENPJP6120 ohmterminationNoterminationJP5JP5JP5JP5JP5JP6 JP6JP6Factorysettings asshownNote:Relay outputs arerated at 10-30 VDC or240 VAC @ 5 A resistive(non-inductive).Digital input connectionsshown when using factorydefault jumper settings1111 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22LoadLoadLoadP1503 P1504 LoadRelay Out 1 N.C.Enable0-10 VDCDig. Input 1Analog GNDAnalog input 1Pot. referenceAnalog input +2Analog output 1*Analog output 2**Referenced to J1-1Analog input -2P1408P1510, P1511, P1512P1513, P1514, P1515Dig. Input 2Dig. Input 3Dig. Input 4Dig. Input 5Dig. Input 6Dig. Input 7Dig. Input 8Relay Out 1 COMRelay Out 2 COMRelay Out 1 N.O.Relay Out 2 N.O.Relay Out 1 N.C.232425 26 27 28 29 30P1FaultUSBUSB port1111RS485S G A B S11ActivelowExternalsupplyANAIN2JP1 ANAOUT1JP2VoltageCurrentCommunicationsTermination jumperDigital OutputsControl BoardControl BoardSourcing Current Connections Sinking Current ConnectionsNote: Digital outputs are rated at 24 VDC @ 60 mA resistive (non-inductive).J2 J2P1501Out 1 P1501Out 1P1502Out 2P1502Out 2J3 J3Digital output 1+ (Collector)Digital output 1+ (Collector)Digital output 2+ (Collector)Digital output 2+ (Collector)Digital output 1- (Emitter)Digital output 1- (Emitter)Digital output 2- (Emitter)Digital output 2- (Emitter)External User ReturnExternal User ReturnExternal User +24 VExternal User +24 VInternal +24 VInternal +24 VInternal 24 V ReturnInternal 24 V Return17 1718 1819 1920 2021 2122 2223 2324 24Note: Optional equipment such asinput/output reactors/filters are notshown. See instruction manual MN764Note: See instruction manual MN764for important information regarding ACpower wiring and fusing.Note: Seeinstructionmanual MN764for importantinformationregarding motorand output reactors.Thermostat andcontrol leads mustbe in separateconduits.Frame Size AA 1-Phase Input Drives Frame Size AA 3-Phase Input DrivesFrame Size E Drives Frame Size F DrivesFrame Size B and C Drives Frame Size D DrivesL1 L2 N GNDR1/B+R2 B- T1 T2 T3 TH1 TH2 GND L1 L2 L3 GNDR1/B+R2 B- T1 T2 T3 TH1 TH2 GNDL1 L2 L3B+/R1R2 B- T1 T2 T3 TH1 TH2 GNDTH1 TH2 GNDL1 L2 L3 T1 T2 T3B+/R1 R2 B-L1 L2 L3 B+/R1 R2 B- D1 D2 GND T1 T2 T3MotorChassisGroundMotorChassisGroundTH1 TH2 GNDTH1 TH2 GND D1 D2 GNDL1 L2 L3B+ B- T1 T2 T3TH1 TH2 GNDL1 L2 L3FusesR1/B+R2 B- T1 T2 T3AC Input powerPEStarPointOptional regenresistor(Dynamic Brake)See instructionmanual MN764AC InputDynamic BrakeMotor PowerKeypad ComponentsThe keypad is used toprogram the controlparameters, to operatethe motor and to monitorthe status and outputs ofthe control by accessingthe display options, thediagnostic menus and thefault log. Additionally, driveparameters can be storedin the keypad for futureretrieval.Display FeaturesSpeed ReferenceDefines action of F2 keyDefines action of F1 keyLocal RemotePresent Menu SelectionStop – Forward – ReverseIndicator Lights:(On when indicated Key is active)FWD & REV: Green light indicator.STOP: Red light indicatorJOG: Jog Speed Selected Green light indicatorDisplay Diagnostics –I/O StatusI/O Function configurationModified ParametersControl Operation DataCustom UnitsFault Display – 10 Faults with Time StampF2 – Clears faults or undo parameter edit changes or functionindicated by text displayed directly above key. Up Arrow Left Arrow Down Arrow Right ArrowMoves cursor to select menu choices.LOCAL/REMOTE – Switches between local and remotemodes.HELP – Provides help at each display screen, setup parameterand fault. Press to view/close help information.JOG – Initiates Jog mode. Press FWD or REV for motion. Onlyin local mode.FWD – When pressed, initiates a forward direction run command.Indicator Lights – (on indicated key)STOP key with red light indicator.FWD key with green light indicator.REV key with green light indicator.JOg key with green light indicator.Keypad Display – Displays status Information during Local orRemote operation. It also displays information during parametersetup and fault or Diagnostic information.F1 – Alternates or "toggles" between the last two menu choicesor function indicated by text displayed directly above key.ENTER – Press EnTER to save parameter value changes. Inthe display mode the EnTER key is used to directly set the localspeed reference. It is also used to select other operations whenprompted by the keypad display.MENU/ESC – Selects the menu display when viewing status.The following menu items are shown: Status, Basic Params,Advanced Prog, Event Log, Diagnostics and Display Options.Backs up one level for other screens.REV – When pressed, initiates a reverse direction run com-mand.STOP – Initates a stop command. note: Pressing the stop keytwice in succession will immediately disable the drive placingthe motor in a coast stop condition.STATUS FWD LOCAL159.5V 600RPM6.2A 20.0HZDIAG 600R MAINDigital Input Jumper SettingsPlease consult the VS1SP Installation and Operation Manual, MN764, before operating the drive.Also, please read the precautionary and warning statements in the Safety Notice, Paragraph 1.2, in MN764. |
Related manuals for Baldor VS1SP
Baldor VS1GV Installation And Operational Manual
Baldor BC142 Installation And Operation Manual
Baldor VS1SM Installation & Operating Manual
Baldor VS1MX Installation & Operating Manual
Baldor VS1MXS51 Installation & Operating Manual
Baldor VS1GV21-1B Installation & Operating Manual
Baldor LD Series Installation And Operating Manual
Baldor BC140 Installation & Operating Manual
Baldor ID15J1F50-ER Installation And Operating Manual
Baldor DBSC105-AAA-1 Installation And Operating Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine