EZ-SCREEN LS Safety Light Screenp/n 190579 Rev A 1Receiver Indicators Emitter IndicatorsSystem Operation, Diagnostics and TroubleshootingBoth emitter and receiver feature 7-segment Diagnostic Displays and individual Status LEDs to provide continuousindication of operating status, configuration and error conditions. Active Alignment (Segment) Indicators provide forbeam block information and easier installation.Run Mode: Indicated by the sensor’s status LEDs:• Solid RED (Blocked condition, OSSDs OFF),• Solid GREEN (Defined area clear, OSSDs ON; Emitter transmitting)• Flashing GREEN (Blanking enabled, Defined area clear, OSSDs ON);Lockout condition: Indicated by the sensor’s status LED• Flashing RED (Lockout, in conjunction with displayed error code, see below)See EZ-SCREEN LS instruction manual p/n 179480 for complete installation, operational, and troubleshootinginformation, and applicable cautions and warnings.ReceiverStatus Indicators• A single red/green Status indicator shows when the OSSD outputs are ON (GREEN) or OFF (RED),blanking is enabled (flashing GREEN), or the System is in Lockout status (flashing RED).• An amber RUN Mode indicator shows when the system is operational (not in lockout).Diagnostic Display(Multiple-digit codes are sequential, followed by a pause)Operational Codes (RUN Mode, amber LED is ON)Code Description- RUN Mode (single dash)C 1 Sensor configured for Scan code 1C 2 Sensor configured for Scan Code 2Note: both emitter and receiver must be configured for the same Scan CodeC H 1 The first sensing beam (CH1 synchronization beam) at the display end of sensor is blocked (mustremain clear) or the receiver Scan Code does not match the emitter Scan Code.n n n The number of blocked beams.H Cascade Stop Input open (stop command)