Baumer UNAM 30U6103/S14 Quick Start Manual
Also see for UNAM 30U6103/S14: Operating instructions
UNAM 30U6103/S1410129076Í?*,zlÂÂ*ÂuÎ1/2Ultraschall-SensorenUltrasonic sensorsDétecteurs à ultrasonsDistanz messender Sensormit Analogausgang 0 - 10 VDistance measuring sensorwith analog output 0 - 10 VDétecteur de mesure avecsortie analogique 0 - 10 VCanadaBaumer Inc.CA-Burlington, ON L7M 4B9Phone +1 (1)905 335-8444ChinaBaumer (China) Co., Ltd.CN-201612 ShanghaiPhone +86 (0)21 6768 7095DenmarkBaumer A/SDK-8210 Aarhus VPhone: +45 (0)8931 7611FranceBaumer SASFR-74250 FillingesPhone +33 (0)450 392 466GermanyBaumer GmbHDE-61169 FriedbergPhone +49 (0)6031 60 07 0IndiaBaumer India Private LimitedIN-411058 PunePhone +91 20 66292400ItalyBaumer Italia S.r.l.IT-20090 Assago, MIPhone +39 (0)2 45 70 60 65SingaporeBaumer (Singapore) Pte. Ltd.SG-339412 SingaporePhone +65 6396 4131SwedenBaumer A/SSE-56133 HuskvarnaPhone +46 (0)36 13 94 30SwitzerlandBaumer Electric AGCH-8501 FrauenfeldPhone +41 (0)52 728 1313United KingdomBaumer Ltd.GB-Watchfield, Swindon, SN6 8TZPhone +44 (0)1793 783 839USABaumer Ltd.US-Southington, CT 06489Phone +1 (1)860 621-2121www.baumer.com/worldwideBaumer Electric AG · CH-8501 FrauenfeldPhone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144AbmessungenDimensionsDimensionsM30 x 1,5M12 x 1 58,57081SW 36Teach-inLED• Alle Masse in mm• All dimensions in mm• Toutes les dimensions en mmElektrischer AnschlussConnection diagramsSchéma de raccordementoutput0VBN (1)BK (4)BU (3)+VSZAnalog BN = Braun/brown/brunBK = Schwarz/black/noirBU = Blau/blue/bleuWH = Weiss/white/blanc• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten• Disconnect power before connecting the sensor• Mettre l’installation hors tension avant le raccordement du détecteurAnschlussbelegungPin assignmentRaccordement1423+VS0VBedienungsanleitung Operating instructions Notice d'utilisationEinstellung der Ausgangsfunktion 0...10VTeach-in Verriegelung Teach-in locking Verrouillage du Teach-inrespectively after the end of the last Teach-in process.5 min. nach jedem Power-up, 5 min. after every power-up, 5min.après chaque mise sousbzw. nach dem Ende des letzten Teach-in Vorgangs. tension resp. après fin du dernier processus Teach-in.Einstellung der Ausgangsfunktion 10...0VSensor in die Werkseinstellung zurücksetzenTeach-in-Taste ca. 2s drücken bis die Zwei-1. Den Sensor in den Einstellmodus bringen:farb-LED gelb/rot blinkt. Taste loslassen.2. Die LED blinkt rot. Das Objekt an die gewünschtesensornahe Bereichsgrenze (Sdc=0V) bringen unddie Teach-in-Taste kurz drücken.3. Die LED blinkt gelb. Das Objekt an die gewünschtesensorferne Bereichsgrenze (Sde=10V) bringen unddie Teach-in-Taste kurz drücken.1. Sensor in den Einstellmodus bringen. Siehe 1. oben.2. Objekt zuerst an die sensorferne Bereichsgrenze(Sde=0V) bringen und wie oben unter 2. einlernen.3. Objekt an die sensornahe Bereichsgrenze (Sdc=10V)bringen und wie oben unter 3. einlernen.Wird der Sensor, ohne dass sich ein Objekt im Erfas-sungsbereich befindet, geteacht oder wird die Teach-inTaste länger als sechs Sekunden gedrückt, wird derSensor in die Werkseinstellung zurückgesetzt. DerSensor zeigt dies durch schnelles Blinken beider LEDs an.4. Bestätigung des erfolgreichen Teach-Vorgangs durch4. Bestätigung des erfolgreichen Teach-Vorgangs.leuchten beider LEDs für 2s.Adjustment of 0...10V operation rangeAdjustment of 10...0V operating rangeResetting to original factory settingsfor approx. 2 secs until the bicolor LED flashesamber/red. Release button.1. Adjustment mode: Press the Teach-in button2. LED flashes red. Place the target at the requiredsensor close limit (i.e.: the closest the target will getto the sensor - Sdc=0V) and press the Teach-inbutton.3. LED flashes amber. Place the target at the requiredsensor far limit (i.e.: the farthest the target will befrom the sensor - Sde=10V) and press the Teach-inbutton.1. Adjustment mode: see paragraph 1. above.2. Place the object first at the sensor far limit (Sde=0V)and proceed according to paragraph 2. above.3. Place the object at the sensor close limit (Sdc=10V)and proceed according to paragraph 3. above.Performing steps 1 and 2 above without an objectwithin in the sensor's range, or holding the buttondown for >6secs, will automatically restore the originalfactory settings. Fast flashing of both LEDs indicatessuccessful completion of the resetting.4. Successful completion of Teach-in procedure is4. Confirmation of successful Teach-in procedure.confirmed by both LEDs being "on" for approx. 2secs.Ajustage de la plage travail 0...10VAjustage de la plage travail 10...0VRéinitialisation des fonctions originales2. LED rouge clignotante. Placer I'objet à détecter à lavaleur de départ de la portée de détection (la cible estproche du détecteur - Sdc=0V) et presser le boutonTeach-in.3. LED orange clignotante. Placer I'objet à détecter à lavaleur finale de la portée de détection (la cible est loindu détecteur - Sde=10V) et presser le boutonTeach-in.1. Ajustage: voir paragraphe 1. ci-dessus.2. Placer I'objet à détecter à la valeur finale de la portéede dét. (Sde=0V) et suivre le para. 2 ci-dessus.3. Placer I'objet à la valeur de départ de la portée dedét. (Sdc=10V) et suivre le para. 3 ci-dessus.Exécuter les étapes 1 et 2 ci-dessus sans objet dans lazone de détection, ou maintenir le bouton pendant >6s,réinitialisera automatiquement les fonctions originales.Le clignotement rapide des deux LEDs indique lavalidation de la réinitialisation.4. La procédure Teach-in est validée par le4. Voir paragraphe 4. ci-dessus.fonctionnement des 2 LEDs pendant environ 2 sec.2secs jusqu'à ce que la LED bicolore orange/rougeclignote. Relâcher le bouton.1. Ajustage: presser le bouton Teach-in pedant environ |
Related manuals for Baumer UNAM 30U6103/S14
Baumer UNAM 30U6103 Quick Start Manual
Baumer UNDK 30U6103 Quick Start Manual
Baumer UNDK 30U6112/S14 Quick Start Manual
Baumer UNDK 30U6104 Quick Start Manual
Baumer UNAM 18I6903/S14 Quick Start Manual
Baumer UNAM 18I6903/S14 Quick Start Manual
Baumer UNDK 30U6103/S14 Manual
Baumer UNCK 09G8914 Quick Start Manual
Baumer UNDK 10N8914 Quick Start Manual
Baumer UNDK 09G8914 Quick Start Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine