Baumer UNDK 10N8914/S35A Manual
Also see for UNDK 10N8914/S35A: Operating instructionsManual
UNDK 10N8914/S35A101614461/2IND. CONT. EQ.1DD2Ultraschall-SensorenUltrasonic sensorsDétecteurs à ultrasonsNäherungsschalterProximity sensorDétecteur de proximitéCanadaBaumer Inc.CA-Burlington, ON L7M 4B9Phone +1 (1)905 335-8444ChinaBaumer (China) Co., Ltd.CN-201612 ShanghaiPhone +86 (0)21 6768 7095DenmarkBaumer A/SDK-8210 Aarhus VPhone: +45 (0)8931 7611FranceBaumer SASFR-74250 FillingesPhone +33 (0)450 392 466GermanyBaumer GmbHDE-61169 FriedbergPhone +49 (0)6031 60 07 0IndiaBaumer India Private LimitedIN-411058 PunePhone +91 20 66292400ItalyBaumer Italia S.r.l.IT-20090 Assago, MIPhone +39 (0)2 45 70 60 65SingaporeBaumer (Singapore) Pte. Ltd.SG-339412 SingaporePhone +65 6396 4131SwedenBaumer A/SSE-56133 HuskvarnaPhone +46 (0)36 13 94 30SwitzerlandBaumer Electric AGCH-8501 FrauenfeldPhone +41 (0)52 728 1313United KingdomBaumer Ltd.GB-Watchfield, Swindon, SN6 8TZPhone +44 (0)1793 783 839USABaumer Ltd.US-Southington, CT 06489Phone +1 (1)860 621-2121www.baumer.com/worldwideBaumer Electric AG · CH-8501 FrauenfeldPhone +41 (0)52 728 1122 · Fax +41 (0)52 728 1144AbmessungenDimensionsDimensions2,972,9 15Teach-inLE D33,21210,4M8 x 16,7 2717,914• Alle Masse in mm• All dimensions in mm• Toutes les dimensions en mmElektrischer AnschlussConnection diagramsSchéma de raccordementNPN Schliesser (NO)NPN make function (NO)NPN à fermeture (NO)NPN Öffner (NC)NPN break function (NC)NPN à ouverture (NC)oderorou0 VWH (2)BU (3)BN (1)BK (4)+VSoutputcontrol/Teach-inNPN ZBN = Braun/brown/brunBK = Schwarz/black/noirBU = Blau/blue/bleuWH = Weiss/white/blanc• Vor dem Anschliessen des Sensors die Anlage spannungsfrei schalten• Disconnect power before connecting the sensor• Mettre l’installation hors tension avant le raccordement du détecteurAnschlussbelegungPin assignmentRaccordement1 / +VS 3 / 0 V4 / Output2 / cont/Teach-InBedienungsanleitungTeach-in Verriegelung 5 min. nach jedem Power-up,bzw. nach dem Ende des letzten Teach-in Vorgangs.Einstellung Schaltpunkt Sde1. Den Sensor in den Einstellmodus bringen:Teach-in-Taste ca. 2s drücken oder externen Teach-in-Anschluss mit +Vs verbinden bis die LED grünblinkt. Taste loslassen bzw. die Verbindung öffnen.2. Die LED blinkt grün. Das Objekt an die gewünschteBereichsgrenze bringen und die Teach-in-Taste kurzdrücken oder den externen Teach-in-Anschluss kurzmit +Vs verbinden.3. Bestätigung des erfolgreichen Teach-Vorgangs durchLeuchten beider LEDs für 2s.Einstellung der Ausgangafunktion (NO/NC)1. Den Sensor in den Einstellmodus bringen:Teach-in-Taste ca. 4s drücken oder externen Teach-in-Anschluss mit +Vs verbindenbis die LED rotblinkt. Taste loslassen bzw. die Verbindung öffnen.2. Die LED zeigt nun die Ausgangsfunktion an. Grün be-deutet Schliesser, rot Öffner. Durch kurzes Drückender Taste oder kurzes Verbinden des externen Teach-in-Anschlusses mit +Vs kann die Ausgangsfunktion um-geschaltet werden.3. Die gewählte Ausgangsfunktion wird abgespeichertindem die Teach-in-Taste ca. 2s gedrückt oder derexterne Teach-in Anschluss ca. 2s mit +Vs verbundenwird. Bestätigung des erfolgreichen Teach-Vorgangsdurch Leuchten beider LEDs für 2s.Operating instructionsTeach-in locking 5 min. after every power-up,respectively after the end of the last Teach-in process.Adjustment switching point Sde1. Adjustment mode:Press the Teach-in button or connect the whiteTeach-in wire to +Vs for approx. 2 secs until the LEDflashes green. Release button or disconnectTeach-in wire.2. LED flashes green. Place the target at the requiredscanning range and press the Teach-in button orconnect the external white Teach-in wire shortlyto +Vs.3. Successful completion of Teach-in procedure isconfirmed by both LEDs being „on“ for approx. 2 secs.Programming of output function (NO/NC)1. Adjustment mode:Press the Teach-in button ot connect the externalTeach-in wire to +Vs for approx. 4 secs until the LEDflashes red. Release button or disconnectTeach-in wire.2. The LED shows the output function of the sensor.Green indicates NO, red indicates NC. Outputfunction is changed by either holding down theTeach-in button or by connecting the externalTeach-in wire to +Vs for a short time.3. The chosen output function is saved by holdingdown the Teach-in button or by connecting theexternal Teach-in wire to +Vs for approx. 2 secs.Successful completion ot the Teach-in procedure isconfirmed by both LEDs being „on“ for approx. 2 secs.Notice d'utilisationVerrouillage du Teach-in 5 min après chaque mise soustension resp. après la fin du dernier processus Teach-in.Ajustage du point de commutation Sde1. Ajustage:Presser le bouton Teach-in ou connecter le Teach-inexterne avec +Vs pendant environ 2 secondesjusqu'à ce que la LED vert clingote.Relâcher le bouton ou déconnecter le Teach-in externe.2. LED clignote en vert. Placer l'objet à détecter à ladistance désirée et presser le bouton Teach-in ouconnecter brièvement le Teach-in externe (WH)avec +Vs.3. La validation de la procédure Teach-in est confirméepar l'état de fonctionnement des deux LEDspendant 2 secs.Réglage de la fonction de sortie (NO/NC)1. Ajustage:Presser le bouton Teach-in ou connecter le fil duTeach-in externe sur +Vs pendant 4s environ jusqu'àce que la LED rouge clignote. Relâcher ensuite lebouton ou déconnecter le fil.2. La LED indique la fonction de sortie du détécteur.Vert pour NO, rouge pour NC. Vous pouves ainsichanger la fonction de sortie en appuyant rapidementsur le bouton Teach-in ou connectant rapidement lefil du Teach-in externe sur +Vs.3. Valider la fonction de sortie choisie en pressant lebouton Teach-in ou en connectanc le fil du Teach-inexterne sur +Vs pendant 2s environ. Les LED rougeet verte s'allument pendant 2s pour confirmer quele réglage a bien été pris en compte. |
Related manuals for Baumer UNDK 10N8914/S35A
Baumer UNDK 10N8914/S35A Manual
Baumer UNDK 10N8914/KS35A Manual
Baumer UNDK 10N8914/KS35A Manual
Baumer UNDK 10P8914/S35A Manual
Baumer UNDK 10P8914/KS35A Manual
Baumer UNDK 10P8914/KS35A Manual
Baumer 10P8914/S35A Manual
Baumer UNDK 20N6914/S35A Manual
Baumer UNDK 20P6914/S35A Manual
Baumer UNDK 20P7914/S35A Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine