CanadianSolar CSCU-ST-WL01 Quick Installation Manual
Smart Data Logger (WIFI&LAN) Quick Installation GuideModel:CSCU-ST-WL01/ CSCU-ST-WLP01Part No: 91000273; Release Date: 2023/09StatementPlease read this guide carefully before using the product, and keep it in a placewhere maintenance personnel can easily find it.Due to product version upgrades or other reasons, the content of this documentmay be updated from time to time. Users should refer to the actual productpurchased and can download the latest version of the manual materials throughthe official website or sales channels. Unless otherwise agreed, this document isintended as a guide only. All statements, information, and recommendations inthis document do not constitute a warranty of any kind, express or implied.Without the written permission of the company, no entity or individual mayextract, copy, or disseminate the contents of this document in any form.Install The Network CableStep 1: Remove the “Plastic Nut”, “Thread Clamp Claw”, and “Sealing Ring”in turn;Step 2: Pass the network cable plug through the “Plastic Nut”, “Thread ClampClaw”, and “Sealing Ring” (with opening) in the direction as shown inthe figure below.Name of each part1 2 3 4 5 6EthernetPortRJ45 Plugto StickSealingRingThread ClampClawPlasticNutRJ45 Plug tothe routerStep 3: Fully embed the “Sealing Ring” into the “Thread Clamp Claw”.Step 4: Connect the “RJ45 Plug” to the datalogger and tighten the “PlasticNut”.Install Data Logger1. Installation StepsStep 1:Find the communication interface on the inverter and unscrewthe protective cap;Step 2:Insert the data logger along the interface guide slot;Step 3:Tighten the fastening nut clockwise.2. WIFI Network ConfigurationIf you want to connect the Data Logger to the WIFI network, you need todisconnect the network cable from the router. Then connect the data logger tothe WIFI network according to the steps of "Data Logger WIFI NetworkConfiguration" in the APP User Guide. After the LAN or WIFI network connectionis successful, the subsequent function confirmation can be performed.3. Confirmation of Data Logger Status Confirm the status of the data logger through the indicator lightColor Status Note Description-Off poweredoffdata logger is not tightened orpowered onSteady on for 5s power-oninitializationdata logger is in a power oninitialization stateBlinking(1s on,1s off) normaloperationcommunication with server andinverter is normalBlinking(1s on,1s off)error state communication with the server isabnormalRedBlinking(1s on,1s off) error state communication with the inverter isabnormalSteady on error state communication with the inverterand server is abnormal4. Abnormal Status HandlingIf there is any abnormal platform data, please refer to the table below andcomplete simple troubleshooting based on the status of the LED lights. If the faultcannot be resolved or the indicator light fault status is not reflected in the tablebelow, please contact after-sales service for assistance.(NOTE:Use the following table one minute after the WIFI network is configuredsuccessfully)Color Status Note Quick TroubleshootingYellow Blinking(1s on,1s off)error stateCheck the WIFI connection status. Ifit cannot be solved, please contactthe distributor.RedBlinking(1s on,1s off)error stateCheck if the connection between thedata logger and the photovoltaicequipment is normal.Steady onerror state1. Check if the connection betweenthe data logger and thephotovoltaic equipment is normal;2. Check the WIFI connection status.If it cannot be solved, pleasecontact the distributor.5. Data Logger One-to-many Installation (only CSCU-ST-WLP01 is supported)If you need to collect data on multiple inverters, connect them in daisy chain modeusing an RS485 communication cable by referring to the CommunicationConnection section in the inverter user manual.NOTE: Precautions for installing the data loggerinsert and remove the data logger after power is off.YellowGreenYellow1 2 3 4 5 6Due to space constraints, the RJ45 plug cannot usea protective cap. To ensure good sealing, thediameter of the network cable should be 4 ~ 7mm.Please ensure that the data logger is working properly beforeleaving the site. If any abnormal conditions are found, pleasecontact your distributor as soon as possible. |
Related manuals for CanadianSolar CSCU-ST-WL01
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine