3V TMControl SystemVVT® Zone ControllerPressure Dependent ControlInstallation, Start-Up andConfiguration InstructionsPart Number 33ZCVVTZC-01CONTENTSPageSAFETY CONSIDERATIONS ...................... 1GENERAL ........................................ 2INSTALLATION ................................ 2-26General .......................................... 2Zone Controller Hardware ........................ 2Field-Supplied Hardware ......................... 2• SPACE TEMPERATURE SENSOR• OPTION BOARD• PRIMARYAIR TEMPERATURE SENSOR• SUPPLY AIR TEMPERATURE (SAT) SENSOR• DUCT AIR TEMPERATURE SENSOR• RELATIVE HUMIDITY SENSOR• INDOOR AIR QUALITY (CO2) SENSORMount Zone Controller ........................... 4• LOCATION• MOUNTINGConnect the Power Transformer .................. 5Install Sensors .................................. 15• SPACE TEMPERATURE SENSOR INSTALLATION• SYSTEM PILOT• PRIMARYAIR TEMPERATURE SENSORINSTALLATION• DUCT TEMPERATURE SENSOR (33ZCSENDAT)INSTALLATION• SUPPLY AIR TEMPERATURE (33ZCSENSAT)SENSOR INSTALLATION• INDOOR AIR QUALITY SENSOR INSTALLATION• HUMIDITY SENSOR (WALL-MOUNTED)INSTALLATIONRemote Occupancy Contact ..................... 21Connect the Outputs ............................ 21Modulating Baseboard Hydronic Heating ........ 23Connect the Carrier Communicating NetworkCommunication Bus .......................... 23• COMMUNICATION BUS WIRE SPECIFICATIONS• CONNECTION TO THE COMMUNICATION BUSSTART-UP .................................... 26-29Perform System Checkout ...................... 26Network Addressing ............................ 27Initial Operation and Test ........................ 27Fan and Heat Configuration and Test ............ 27System Balancing ............................... 27Status Table ..................................... 28CONFIGURATION TABLES ................... 29-40Alarm Configuration Table ...................... 29Terminal Service Configuration Table ........... 30Damper Service Configuration Table ............ 33Holiday Configuration Table ..................... 33Linkage Configuration Table .................... 33Language Configuration Table .................. 35Master Service Configuration Table ............. 35Time Schedule Configuration Table ............. 36Option Service Configuration Table ............. 37Set Point Configuration Table ................... 39MAINTENANCE TABLES ..................... 40-51System Pilot Maintenance Table ................. 40System Pilot Alternate Maintenance Table ....... 40Linkage Maintenance Table ..................... 41Master Zone Maintenance Table ................. 43Time Schedule Maintenance Table .............. 44System Commissioning Maintenance Table ..... 45Zone Status Maintenance Table ................. 47Zone Device Maintenance Table ................. 47Zone Maintenance Table ........................ 47Zone Commissioning Maintenance Table ....... 50OPERATION .................................. 51-54System Mode Selection ......................... 51Linkage ......................................... 52• AIR SOURCES THAT SUPPORT LINKAGE• NON-LINKAGE CONTROLLED AIR SOURCESSystem Modes .................................. 53Air Terminal Modes ............................. 53APPENDIX A -- SYSTEM OPERATIONFLOW CHARTS ............................ 55-58SAFETY CONSIDERATIONSSAFETY NOTEAir-conditioning equipment will provide safe and reli-able service when operated within design specifications.The equipment should be operated and serviced only byauthorized personnel who have a thorough knowledgeof system operation, safety devices and emergencyprocedures.Good judgement should be used in applying anymanufacturer's instructions to avoid injury to personnel or&tmage to equipment and property.Disconnect _dl power to the unit before performing mainte-nance or service. Unit may automatically start if power isnot disconnected. Electrical shock and personal injurycould result.If it is necesstuy to remove and dispose of mercury contac-tol_ in electric heat section, follow all local, state, andfederal laws regarding disposed of equipment containinghazardous materi_d s.Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Book 1 [4 PC 111 Catalog No 533-30011 Printed in U.SA Form 33ZC-13SI Pg 1 10-04 Replaces: NewmTab 11a 13a