Installation notesDANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388E-mail: sales@danlers.co.uk Web: www.danlers.co.ukCompany Registered Number 2570169 VAT Registration Number 543 5491 38Products available from DANLERS• PIR occupancy switches • Daylight linked dimmers • Manual high frequency dimmers• Photocells • Radio remote controls • Time lag switches • Outdoor security switches• Dimmers • Heating, ventilation and air-conditioning controls • Bespoke / O.E.M. productsPlease call for more information or a free catalogue.This product conforms to BS EN 60669-2-1 and BS EN 55015.Please ensure the most recent edition of the appropriate local wiring regulations are observedand suitable protection is provided e.g. a 10 amp circuit breaker and voltage surge protection.Please ensure that this device is disconnected from the supply if an insulation test is made.This product is covered by a warranty which extends to 5 years from the date of manufacture.Precautions and WarrantyCompact person detector, PIR switchCOPD COPD BKDANLERS Compact Person Detector is IP66 rated and can besurface mounted onto an external wall. It incorporates a passiveinfra-red quad sensor to detect movement of a warm body withinthe detection zone (diagram A) and the COPD (BK) includes aphotocell to monitor the ambient light level.The detection range is about 10 metres over 120 degrees, the rangereduces to about 8m at the extremes to prevent nuisance switching.On detecting movement, if the ambient light is dark enough, theCOPD (BK) will switch the load on. The ambient threshold can beset by the user to between approximately 10 and 1000 lux via theinternal LUX adjuster (diagrams B and C). The photocell can bedisabled via the internal mode button (see overleaf).If no more movement is detected within a pre-selected time,then the PIR switch will turn the load off. This time lag can be setvia the TIME adjuster to 10 seconds, 20 seconds, 40 seconds,80 seconds, 2 minutes 30 seconds, 5 minutes,10 minutes, 20minutes or 40 minutes (diagram D).Product codes:COPD Grey enclosureCOPD BK Black enclosureLoadingThe switch should only be connected to a 230V 50Hz AC supply.These PIR switches can switch up to:6 amps (1500W) of resistive loads.6 amps (1500W) of fluorescent loads.3 amps (750W) of electronic and wire wound transformer loads.2 amps (500W) of CFL, 2D lamps, LED Drivers and LED lampsand fittings.1 amp (250W) of fansMinimum load 2W resistive, suitable for most energy saving lamps,LEDs and emergency fittings.01/03/19 INS970 COPDVariantsLow voltage variants can be supplied, coded by the following suffixes:• 12VAC 12V - (ac supply) operation• 12VDC 12V - (dc supply) operation• 24VAC 24V - (ac supply) operation• 24VDC 24V - (dc supply) operationTrouble shootingThe COPD cannot be made to switch on during bright days• The COPD should have the lux set to inactive via the internal modebutton (see diagram B)The PIR does not detect• Person is too far from the COPD switch, see detection diagram.• Person is moving unusually slowly (perhaps when testing).The PIR stops working• Ensure the unit is mounted correctly so that no water can enter.The PIR False triggers• Detector is exposed to air movement on breezy days.