ISI-MNPIR5MSWCeiling Flush Mount Passive Infra Red(PIR) Occupancy Detector & PhotocellInput: 100-240 Vac 50/60HzThis fl ush mounted ISI-MNPIR5MSW is suitable foreasy mounting through a 38/40mm diameter holeinto a ceiling void which is at least 60mm deep.Confi gurable for any room occupancy style, via thefree to download DANLERS ISI APP on GooglePlay or Apple APP Store.INSTALLATIONTo be installed by a competent person withreference to BS 7671 or equivalent local standards.If in doubt consult a qualified electrician.• Plan where the ISI-MNPIR5MSW is to be located(see diagram 1). Switch off supply and checkfor hidden cables and pipes. Make a 38/40mmdiameter hole through a standard ceiling board.• The MNPIRPSSW should be connected asshown in diagram 2:L - Live in. N - Neutral in. SW - Switched line.• Ensure both springs are fi tted to the ISI-MNPIR5MSW in the correct orientation (seediagram 3)• Fit one end of the Telejack into the MNPIRPSSWthe other end fi t to the ISI-MNPIR5SW. (seediagram 4)• Push both connected products into the ceilingvoid.OPERATIONTo check the operation of the ISI-MNPIR5MSWsubject to software version:• Turn on the supply then after 20 seconds if thesensor has recognised movement of a personwithin its zone of detection the integral red LEDon ISI-MNPIR5MSW will flash before the red LEDturns off .• Thereafter, every time movement is detected byISI-MNPIR5MSW the integral red LED will fl ash.The control also features adjustable time out (timelag) control and daylight threshold control whichare confi gured by the DANLERS ISI APP.PRECAUTIONS• Do not place the ISI-MNPIR5MSW near heatsources, fans or in ventilated ceiling voids.• Do not place close to, or positioned suchthat, any light source points directly into the ISI-MNPIR5MSW.• Ensure wires and cables are securely held withinthe connection terminals.• The ISI-MNPIR5MSW should be protected by a5 or 6 Ampere mcb or fuse.• Disconnect the ISI-MNPIR5MSW from thecircuit before performing insulation testingof the wiring circuit.PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCTNOTE: ISI-MNPIR5MSW is only compatible to work with DANLERS ISI enabled app.TECHNICAL DETAILSINPUTVoltage: 100 - 240VacFrequency: 50/60HzMax. mains current: 20mAStandby current: 14mALOADINGFluorescent lamps,either high frequency 2 amps (450W)Incandescent or mainshalogen lamps 2 amps (450W)LED lamps and drivers(PF ≥ 0.95). 2 amps (450W)RADIO TRANSCEIVEROperating frequencies: 2.4... 2,480 GHzMax. output power: +4 dBmLUX PARAMETERSRange: 5 - 2000 luxOPERATING CONDITIONSNote: The temperature diff erence between thedetection target and the background must be atleast 4 °C.Ambient temperature: -20... +40 °CStorage temperature: -25... +75 °CMax. relative humidity: 0... 80%, non cond.CONNECTORSTerminal blockWire size: 0.5mm2 - 2.5mm2 solidor strandedWire strip length: 6-7mmTightening torque: 0,4 Nm/4 Kgf.cmMECHANICAL DATADimensions: See diagram 3Weight: 102g (unpacked)Degree of protection: IP40Protection class: Built-in Class 2Material (casing) Flame-retardantpolycarbonateFinish / Colour Matt /White (RAL 9003)Protection class: Built-in Class 2CONFORMITY AND STANDARDSEMC emission:EN 301 489-1 V2.2.0,EN 301 489-17 V3.1.1,EN 55032: 2015,EN61000-3-2: 2014,EN61000-3-3: 2013DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388 E-mail: sales@danlers.co.ukwww.danlers.co.uk Company Registered Number 2570169 VAT Registration Number 543 5491 3817/08/2023 DAT0235 ISI-MNPIR5MSWEMC immunity:EN 301 489-1 V2.2.0,EN 301 489-17 V3.1.1Environment:Complies with WEEE and RoHS directives5 YEAR WARRANTYISI-MNPIR5MSW comes with a 5 yearwarranty from the date of manufactureand is CE marked.