DEGA FWL Home Instruction Manual
PAGE 2 PAGE 3ISO 9001:2008Quality Management SystemsSystéme de Qualitéwww.sgs.com1342MINIMU M10c mMAXIMU M30.5cmMINIMU M10cmza kázanáoblast121c mKDEKOLIVVT …TOOBLAST Iobr.2obr.1FIGURE 1MINIMUMMINIMUMMAXIMUMTHE MOSTCONVENIENTLOCATIONTHE ACCEPTABLEAREAANYWHEREWITHIN THISAREATHE RESTRICTEDAREAFIGURE 2FOR YOUR PROTECTIONTECHNICAL DATA AND INFORMATIONDESCRIPTION OF THE PRODUCTINSTALLATION, ASSEMBLY AND DISASSEMBLYDEGA FWL HomeSingle Station Smoke Detector (wireless)Wireless Optical-Smoke Fire DetectorContentPage 2 / For your protectionPage 2 / Technical data and informationPage 3 / Description of the productPage 3 / Installation, assembly and disassembly of the detectorThe recommended procedure for a typical one-storey dwellingThe recommended procedure for a typical multi-storey dwellingWhere to install a smoke detectorWhere not to install a smoke detectorAssembly of the detectorDisassembly of the detectorConnecting the batteryReplacing the batteryPage 5 / Testing the detectorPage 5 / MaintenancePage 5 / What to do in the case of firePage 6 / TroubleshootingPage 6 / General warranty terms and conditionsWatch out for static electricityPrior to installing or handling the product, ensure that you do not have anaccumulated static charge. Touch a grounded metal object to trigger thedischarge of any accumulated electric charge. Otherwise the product couldsuffer damage.In the event of any failure of the equipment unplug it immediatelyIf you notice an unusual odour or smoke emanating from the product, unplugit from the mains and from all peripherals. Continued operation could resultin injury or property damage. After disconnecting the product deliver it to anauthorised service centre or the manufacturer for inspection.Do not use the product in the vicinity of flammable gases orin areas where there is a potential occurrence of these gases.Do not use electronic equipment in the vicinity of flammable gases; this couldpotentially cause a fire or an explosion. The product is not designed for use inindustrial or commercial spaces nor in „Ex“ hazardous areas.Do not disassemble the product and ensure against its contact with waterContact with internal components of the product may cause an electric shock.In the case of any failure refer the servicing of the product exclusively to acertified service centre. Contact with water can create a short circuit in theproduct and consequent damage to property or personal injury.The smoke detector responds only to visible smokeSmoke detectors start emitting warning signals only in the event of thedetection of smoke or other particles generated during the combustionprocess. Detectors do not respond to heat, flames or gas. The possibility ofa fire is announced by an acoustic signal. Fires often progress very swiftly,however. In such cases, the smoke may not reach the detector rapidly enoughto ensure the safe escape of the people in the building.Use in one household onlyThis smoke detector is designed for use in one household only. In largerbuildings, each housing unit should be equipped with its own detector(s).Smoke detectors should not be installed in non-residential areas; they are nota viable substitute for a comprehensive monitoring system.Install a detector in each roomInstall a detector in every room and on every floor of the building. There aremany reasons why smoke may not reach the sensitive area of the detector. Forexample, if the fire starts in a remote part of the building, on another floor,in the chimney, along a wall, on the roof or in a room behind closed doors, itmay be that the smoke will not reach the area sensitive to the detector rapidlyenough for the detector to provide notice of impending danger to all themembers of the household. The detector is only able to identify fire directly inthe space or in the room in which it is located.Supply voltage: a 6LR61/9V batterySupply voltage in the standby mode: < 40 μASupply voltage in the alarm mode: < 30 mAType of sensor: photoelectric(responsive to visible smouldering smoke)Expected operational life of the sensor in a clean environment: max.5 yearsRadio frequency: 433,92 MHzRange: 50m in an open areaInternal speaker acoustic performance: 85 dB at 1mOperating temperature range: max.-10°C to +50°CRelative humidity of the ambient air: 15 - 90%Certified in accordance with CSN EN 14604 based on the specifications of Decree No.23/2008 of the Ministry of Interior, On the technical conditions for fire protection ofbuildings.1 - Air holes for the access ofsmoke to the sensor of thedetector2 – A “TEST” button3 - A red indicator - „ALARM“(LED, alarm)4 – Piezo-buzzerAttention: The „TEST“ button reliably tests all the functions of the smoke detector.Do not try to test the detector in any other manner. Carry out checking, using the „TEST“button, once a week, and always also after a longer absence.THE RECOMMENDED PROCEDURE FOR A TYPICAL ONE-STOREY DWELLINGAttach the smoke detector to the ceiling or to a wall in each bedroom and in the hall-way outside each bedroom. If the hallway is longer than 9.1 m, place a detector at eachend of the hallway. If you have a cellar, install a detector on the ceiling of the basementspace directly below the staircaseTHE RECOMMENDED PROCEDURE FOR A TYPICAL MULTI-STOREY DWELLINGAttach a smoke detector to the ceiling or to a wall in each bedroom and also in thehallway outside each bedroom. If the hallway is longer than 9.1 m, place a detector ateach end of the hallway. Install additional detectors above the top end of the staircasebetween the first and second floors.WHERE TO INSTALL A SMOKE DETECTOR1. Place a detector in each bedroom and also in the hallway outside each bedroom.2. Place a detector on each staircase and on each floor.3. Once the smoke, heat and flames reach the ceiling, they begin to spread horizontally.Install the detector in the centre of the ceiling.4. If you do not place the detector in the centre of the ceiling, ensure that it is at least10 cm from any corner (see Figure 1).5. A detector installed on the wall must be located at least 10 cm below the ceiling(see Figure 1).6. If a room, hall or corridor is longer than 9.1 m, additional detectors need to beplaced there.7. In the case of a sloping wall or ceiling, place the detector at a distance of 50 cmbelow the top of the wall or the ceiling (see Figure 2).INSTRUCTIONMANUALReproduction of this manual, or any part thereof, in any form, without theprior written permission of DEGA CZ s.r.o. is prohibited.DEGA CZ s.r.o. reserves the right to alter the specifications of the hardware and softwaredescribed in this manual at any time and without prior notice.DEGA CZ s.r.o. bears no liable for any damage resulting from the use of this device! |
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine