DEPENDABLE DIRECT YT-C2 Series Installation Instructions Manual
SPECS120V/277VAC, 60Hz120V 800W Incandescent Lamp800VA Fluorescent Lamp (Rapid Start)277V 1200VA Fluorescent Lamp (Rapid Start)1/6 hpPreset intervals of 15 sec (Test),1 min,5 min, 15 min, and 30 minIndoor use only32˚ to 131˚F (0˚ to 55˚C)95% RH, non-condensing180˚ (at optimal temperature of 20˚ to 25˚C)720 ft 2 (47m2 )VoltageMax Lamp LoadMax motor loadTime Delay AdjustmentEnvironmentOperating TemperatureHumidity RangeCoverage RangeCoverage AreaTOOLS NEEDEDYou will need an insulated fathead screwdriver, wire strippers, and a small athead screwdriverto adjust the sensor dials.DESCRIPTIONCOVERAGE AREAFigure 1: Sensor coverage area(top view)30ft(9.1m)12ft(3.7m)30ft(9.1m)4ft(1.2m)6ft(1.8m)Figure 2: Sensor coverage area(side view)BEFORE INSTALLATIONIMPORTANT:A neutral wire is required for the switch towork properly. If the existing wiring does not matchthedescription for a two-pole circuit, or if you do not have aneutral wire, consult a qualifedelectrician.IMPORTANT:Si le câblage existantne correspond pas à la description d'un circuit bipolaire,consultez un électricien qualifé.)SWITCH OVERVIEWFigure 3: YT-C2 Series sensor switch diagram9. Operation ModeButtonThe sensor has two positions that correspond to operation modes:vacancy (when the button is pressed) and occupancy (when thebutton is released).3. Control PanelCover4. On/Off Button5. LED Indicator6. Time Delay Dial7. Sensor SensitivityRange Dial8. Ambient LightLevel DialCovers the switch’s adjustment dials. Remove the cover to seethe dials.Lets you turn the light or fan on or off.Indicates when the sensor detects motion. The green LED lightsthe On/Off button while the lights or fan are off. When they areon, the LED turns off.Controls how long the light or fan stays on after no motion isdetected.Adjusts the sensitivity setting to avoid unwanted detectionsuch as hallway traffc or adjacent movement.Prevents the sensor from automatically turning the lights orfan on if the area has enough ambient lighting.1. Mounting Yoke2. Fresnel LensLets you mount the switch to the wall.Detects motion.● These instructions describe only the 3-way circuit applications.● For information about other applications,● consult technical support.1. Prepare the switch box● After the power is turned OFF at the circuit breaker box,remove the existing wall plate andmounting screws. Pull the old switch out from the wall box.2. Identify the type of circuit● You may connect the YT-C2 to a single pole or multi-way circuit. If you are unable to clearlyidentify some or all of the wires mentioned in this manual, you should consult with a qualifedelectrician.● In a 3-way circuit (see Fig. 4), two traveler wires connect to both switches. Another wire providespower from the circuit box to one of the switches. A wire connects from one switch to the load.A ground wire may also be connected to a ground terminal on the old switches. A neutral wireshould also be present in both wall boxes.Figure 4: Typical 3-way switch wiringThe YT-C2 Series sensor switch is designed to replace a standard light or fan switch. This devicecan automatically turn lights or a fan on and off by detecting motion from a heat-emitting sourcesuch as a person entering an area. The lights or fan will stay on until no motion is detected andthe time delay has expired. This product offers optimal coverage for random traffc areas suchas hallways, stairways, or large spaces with multiple entries. Use indoors only.● The sensor must have a clear and unobstructed view of the area. If an object blocks thesensor’s lens, the sensor may not detect motion and may turn the lights or fan off even ifsomeone is in the area. Windows, glass doors, and other transparent barriers willobstruct the sensor’s view and prevent motion detection.● The coverage area data is measured under the best temperature condition (20 to 25˚ C),and a higher or lower temperature may not leadto an ideal coverage area (see fgures 1 and 2).WARNING:● Before installing the YT-C2 Series sensor switch,disconnect power to thewall switch box by turning off the circuit breaker or removing the fuse for thecircuit.● For supply connections use 18AWG or larger wires suitable for at least 75°C● Tightly secure the ground wire to ensure that thesensor functions properly.AVERTISSEMENT:● avant d'installer l'interrupteur du capteur de la série YT-C2, débranchezl'alimentation du boîtier d'interrupteur mural en éteignant le disjoncteur ouen retirant le fusible du circuit.● Pour les connexions d'alimentation, WG ou plus adaptésà au moins 75 ° C● fxez fermement le l de terre pour vous assurer que le capteur fonctionnecorrectement.Installation Instructions for YT-C2 SeriesYT-C2 SeriesThree-Way 180°Occupancy and Vacancy Sensor SwitchPlease read all instructions before installing the YT-C2 Series sensor switch.*Intended for use with electronic ballast, Type ICN-4S54-90C-2LS-G, manufactured by PhilipsLighting Electronics N A.Thank you for your purchase from Dependabel Direct, your satisfactionis our top priority. If you have any questions or concerns, please emailus at Support@DependabelDirect.comYM2108TREV 1.1 |
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine