PLANNINGGUIDEWeb: http://www.Dacor.comCorporate Phone: 800-793-0093Specifications are subject to change without notice.See installation instructions for additional details. 11.1442” and 48” WideBuilt-In RefrigeratorsEF42DBSS, EF42NBSS, EF48DBSS, EF48NBSS,IF42DBOL, IF42NBOL, IF48DBOL, IF48NBOL1/6Opening DimensiOnsTo avoid tipping during use, the solid soffit must be within 1”◊(2.5 cm) maximum above the refrigerator. If the solid soffitis higher than 1” (2.5 cm) or one is not available, then therefrigerator must be braced.If the anti-tip boards are needed, they must be attached to therear wall studs 80” to 90” (203 cm to 229 cm) above the floor.See installation instructions for more information.NOTE: A clearance of ¹⁄2” (1.3 cm) must be maintained abovethe top grille in order for the top grille to be removed.4"(10.2 cm)83 ¹/2" (212.1 cm) min.84³/4" (215 cm) max.to bottom of solid soffit24"(60.96 cm) min.77"(196 cm)AWidth(see chart following)Revised04/22/08"(1.3 cm)1 /2Model Series Cutout Width AEF42, IF42 41½” (105.4 cm) to 41¾” (106.1 cm)EF48, IF48 47½” (120.7 cm) to 47¾” (121.3 cm)NOTE: Flooring under refrigerator must be at same level as theroom. Face of cabinetry must be plumb.A grounded 3 prong electrical outlet should be placed within◊4” (10.2 cm) of the right side cabinets or end panel. SeeElectrical Requirements for more information.The water shutoff should be located in the base cabinet on◊either side of the refrigerator or some other easily accessiblearea. If the water shutoff valve is not in the cabinets, theplumbing for the water line can come through the floor orthe back wall. See Water Supply Requirements for moreinformation.See Page 11.15