FRCC.PI.015.A1.22 © Danfoss Commercial Compressors 06/10INSTRUCTIONSH SERIES COMPRESSORS2025303540455055606570-30 -25 -20 -15 -10 -5 0 5 10 15E v a p . T e m p . (°C )C o n d . T e m p . (°C )SH 11KSH 30K2025303540455055606570-30 -25 -20 -15 -10 -5 0 5 10 15E v a p . T e m p . (°C )C o n d . T e m p . (°C )SH 11KSH 30K2025303540455055606570-30 -25 -20 -15 -10 -5 0 5 10 15E v a p . T e m p . (°C )C o n d . T e m p . (°C )SH 5KSH 10KA: Model numberB: Technical numberC: Serial NumberD: Manufacturing yearE: Internal protectionF: Supply voltage rangeG: Run capacitorH: Locked rotor currentMaximum operating currentI: Lubricant type and nominal chargeJ: Approved RefrigerantHRM/HLM/HCM - HRP/HLP/HCP - HRH/HLH/HLJ/HCJModel variation T (R22 / R407C / R410A)HRM/HLM/HCM - HRP/HLP/HCP - HRH/HLH/HLJ/HCJModel variation U (R22 / R407C / R410A)HHP (R407C)Installation and servicing of thecompressor by qualified personnelonly. Follow these instructions and soundrefrigeration engineering practice relating toinstallation, commissioning, maintenance andservice.The compressor must only be usedfor its designed purpose(s) and withinits scope of application (refer to «ope-rating limits»). Consult Applicationguidelines and datasheet availablefrom cc.danfoss.comNever ope-rate compressorwithout termi-nal box cover inplace and secured.The compressor is delivered undernitrogen gas pressure (between 0.3and 0.4 bar / 4 and 6 psi). Do not disas-semble bolts, plugs, fittings, etc... unlessall pressure has been relievedfrom the compressor.Under all circumstances,the EN378 (or other applicablelocal safety regulation) requi-rements must be fulfilled.Wear protective goggles andwork gloves.The compressor mustbe handled with cau-tion in the verticalposition (maximumoffset from the verti-cal : 15°).CSRLine RunCapacitorStartCapacitorPotentialRelay125CSRLine RunCapacitorMDGTHPs180 sTHLPCONTROL CIRCUITF1F1KMKMKMKA KAA1A2A3KAKAKSKSKSL1 L3 L2Q1T1T3T2LLSV KSWiring diagram with pump-down cyclePMQuick connect spade terminalsP terminal box typepushpushpushABCDEFGHIJ400PSC wiringCSR wiringOperating limits Electrical connections Single phaseThree phase (Wiring diagram with pump-down cycle)Ring connect screw terminalsC terminal box typeCT₁ST₂RT₃1 – IntroductionThese instructions pertain to the Performer® HRM/HLM/HCM - HRP/HLP/HCP/HHP - HRH/HLH/HLJ/HCJ scroll compressors used for HVAC systems. Theyprovide necessary information regarding safety andproper usage of this product.2 – Handling and storage•Handle the compressor with care. Use the dedicatedhandles in the packaging. Use the compressor liftinglug and use appropriate and safe lifting equipment.•Store and transport the compressor in an uprightposition.•Store the compressor between -35°C and 70°C /-31°F and 158°F.•Don’t expose the compressor and the packagingto rain or corrosive atmosphere.3 – Safety measures before assemblyNever use the compressor in a flammable atmosphere.•Mount the compressor on a horizontal flat sur-face with less than 7° slope.•Verify that the power supply corresponds to thecompressor motor characteristics (see nameplate).•When installing a compressor model HRP / HLP /HCP / HHP - HRH / HLH /HLJ / HCJ, use equipmentspecifically reserved for HFC refrigerants whichwas never used for CFC or HCFC refrigerants.•Use clean and dehydrated refrigeration-grade cop-per tubes and silver alloy brazing material.1Quick connect spade terminalsP terminal box typeRing connect screw terminalsC terminal box typeWhen HRM compressors are used with R417A, the factory charged oil must be replaced by PVE oil 320HV (120Z5034).