1VQIDC202 © Danfoss 12/2014Quick Guideliving connect® Z,Electronic Radiator ThermostatPreparationliving connect® Z is an electronic radiator thermostat, intendedfor use with water based room radiators. It can be controlled bya Z-Wave certified controller, which supports the appropriatecommand classes.Z-Wavecontrollerliving connect® Zsensorliving connect® Z is supplied with adapters for Danfoss RA valvesand valves with M30 x 1.5 (K) connections, two alkaline AA bat-teries and a 2 mm Allen key.Inserting the batteriesRemove the battery cover and insert two AAbatteries. Make sure the batteries are correctlyoriented.Rechargeable batteries must not be used.When replacing batteries the programme set-tings will be preserved, but after two minutesthe settings for time and date are reset.Installing living connect® ZM must be flashing on the display prior to installing.1. Start by mounting the ap-propriate adapter.RA K2. Tighten RA adapter using theAllen key, hand-tighten the Kadapter (max. 5 Nm).3. Screw the thermostat ontothe adapter and tighten byhand (max. 5 Nm).4. A large M flashes, press to fix the thermostat.Including the device to a networkZ-wavecontroller• Ensure living connect® Z is factory reset.• Activate “Inclusion” on the Z-Wave controller.• Quickly press and release on living connect® Z.• Observe both controller and living connect® Z for status of theprocess.Testing the connectionPress for at least 3 seconds until M is displayed.Press until LI is displayed.Press to test the connection.LI disappears when the connection is made.If no connection can be made, the alarm symboland the antenna symbol flashes.Display and buttonsBattery symbolThe set temperatureNetwork connectionLockAlarmUse to navigate the display and the menus and to set thetemperature, and use to select and confirm.