Datalogic S5N-Px-PK Series Instruction Manual
This product is covered by one or more of the following patents.European Patent 1,111,690 B1S5N-Px-...-PK/NK SERIESINSTRUCTION MANUALCONTROLSOUTPUT LED (S5N-…A00/B01/C01/C10/F00)The yellow LED ON indicates that the NO output status is closed.POWER ON LED (S5N-…G00)The green LED indicates that the sensor is operating.TRIMMER (S5N-…B01/C01)The trimmer can be used to adjust sensitivity; the operating distance increasesturning the trimmer clockwise.WARNING: The trimmer rotation is limited to 270°.Do not apply excessive torque beyond the maximum and minimum pos it i o n s(max 40 Nmm).INSTALLATIONThe sensor can be fixed by means of the M18x1 threaded body througha 18mm hole, using the specific washer and the two CH.24 nuts(1.5Nm maximum tightening torque) or CH.22 nuts, h=8mm, (2Nmmaximum tightening torque) enclosed. Alternatively, the sensor can bemounted through the two housing’s holes using two screws (M3x22 orlonger) and washer.Amongst the various possible solutions, we suggest to choose thecombination that offers the best visibility of the signalling LEDs and theeasiest access to the trimmer.Various orientable fixing brackets areavailable to ease the sensor positioning(please refer to the accessories listed in thegeneral catalogue). The operating distance ismeasured from the front surface of the sensorlens.C models: To improve the detection, theobject has to be moved closer or further awayfrom the front surface of the sensor lens.In case of lateral translation, the object must move as indicated in thefigure.CONNECTIONSThe connections are compliant to the EN 60947-5-2 standard.S5N-…A00/B01/C01/C10/F00+ 10 … 30 VdcDARK- / LIGHT+BROWN 1WHITE 2BLACK 4BLUE 3N.O. OUTPUT0 V* S5N-…G00+ 10 … 30 VdcTEST +BROWN 1WHITE 2BLACK 4BLUE 3TEST -0 V* in case of white wire or pin 2 not connected the sensor works inLIGHT mode for proximity models (C01/C10) and in DARK mode forretroreflex (A00/B01) and receiver (F00).M12 CONNECTORS5N-… A00/B01/C01/C10/F00 S5N-…G00DIMENSIONSTECHNICAL DATAS5N-PA AXIAL VERSION S5N-PR RADIAL VERSIONPower supply: 10 … 30 Vdc (limit values)Ripple: 2 Vpp max.Current consumption(output current excluded): 30 mA max.Outputs: N.O.; PNP or NPN (short circuit protection)Output current: 100 mA max.Capacitive load: Cmax<= 1.5 uF @24V, Iload = 100mACmax<= 3.5 uF @24V, Iload = 10mAOutput saturation voltage: 2 V max.Response time: 1 ms (4 ms mod.F00)Switching frequency: 500 Hz (120 Hz mod.F00)Indicators: OUTPUT LED (YELLOW) mod.G00 excludedPOWER ON LED (GREEN) (mod.G00)Setting: sensitivity trimmer (mod.B01/C01)Operating temperature: -25 … 55 °CStorage temperature: -25 … 70 °CInsulating strength: 500 Vac 1 min., between electronics and housingInsulating resistance: >20 M 500 Vdc, between electronics and housingOperating distance(typical values):A00: 0.1…3.5 m on R2B01: 0.1…2.5 m on R2C01: 1…40 cmC10: 0…10 cmF00/G00: 0…18 mA00: 0.1…2.5 m on R2B01: 0.1…2.0 m on R2C01: 1…30 cmC10: 0…8 cmF00/G00: 0…15 mEmission type: RED (660 nm) (mod.B01) / INFRARED (880 nm) (mod.A00/C01/C10/G00)Ambient light rejection: according EN 60947-5-2Vibrations: 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6)Shock resistance: 11 ms (30 G) 6 shock for every axis (EN60068-2-27)LIGHT/DARK selection:white wire or pin 2 connected to +10…30V LIGHT mode; to 0V DARK modewhite wire or pin 2 not connected LIGHT mode (mod.C01/C10);DARK mode (mod.A00/B01/F00)Housing material: PBTLens material: PMMAMechanical protection: IP67Connections: 2 m cable 4 mm / M12 - 4 pole connectorWeight: 75 g. max. cable vers. / 25 g. max. connector vers.AtEx 2014/34/EU II 3D EX tc IIIC IP67 T85°CSETTINGSetting of S5N-…A00/B01Position the sensor and reflector on opposite sides.Moving the sensor both vertically and horizontally, determine the poweron and off points of the yellow LED (OUT) and then mount the sensor inthe middle of the points defined.B01 Model: Turn the sensitivity trimmer to the maximum position.If necessary reduce sensitivity in order to detect very small targets. Inorder to improve alignment, repeat the procedure detailed above whilstprogressively reducing the sensitivity.Setting of S5N-…F00/G00Position the sensors on opposite sides.Move the sensor both vertically and horizontally, determine the power onand off points of the yellow LED (OUT) and then mount the sensor in themiddle of the defined points.Setting of S5N-…C01Turn the sensitivity trimmer to minimum: the yellowLED is OFF.Position the target to detect in front of the sensor.Turn the sensitivity trimmer clockwise until the yellowLED turns ON (Target detected state, pos.A).Remove the target, the yellow LED turns OFF.Turn the sensitivity trimmer clockwise until the yellow LED turns ON(Background detected state, pos.B).The trimmer reaches the maximum level if the background is notdetected.Turn the trimmer to the intermediate C position, between the two A andB positions.Setting of S5N-…C10The operating distance range of these sensors is factory preset: pleaseconsider this feature when positioning.TEST FUNCTION (S5N-…G00)The TEST+ and TEST- inputs can be used to inhibit the emitter andverify that the system is correctly operating.The receiver output should switch when the test is activated while thebeam is uninterrupted. The inputs activating voltage range is 10 … 30Vdc, whilst respecting the polarity.The emission is switched off connecting TEST+ to Vdc and TEST- to 0V.Datalogic S.r.l.Via S. Vitalino 13 - 40012 Calderara di Reno - ItalyTel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.comHelpful links at www.datalogic.com: Contact Us, Terms and Conditions, Support.The warranty period for this product is 36 months. See General Terms and Conditionsof Sales for further details.For information about the disposal of Waste Electrical andElectronic Equipment (WEEE), please refer to the website atwww.datalogic.com.© 2021 Datalogic S.p.A. and/or its affiliates ALL RIGHTS RESERVED. Withoutlimiting the rights under copyright, no part of this documentation may be reproduced,stored in or introduced into a retrieval system, or transmitted in any form or by anymeans, or for any purpose, without the express written permission of Datalogic S.p.A.and/or its affiliates. Datalogic and the Datalogic logo are registered trademarks ofDatalogic S.p.A. in many countries, including the U.S.A. and the E.U. All other trademarksand brands are property of their respective owners. Datalogic reserves the right tomake modifications and improvements without prior notification.821007360 Rev.AMIN MAXABC |
Related manuals for Datalogic S5N-Px-NK Series
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine