Delta DVP04TC-S Instruction Sheet
Also see for DVP04TC-S: Instruction sheetInstruction sheetInstruction sheet
http://www.delta.com.tw/industrialautomation/ 5011620601-T4E12005-06-20DVP04TC-S Thermocouple SensorsInstruction Sheet1 WARNINGAlways read this manual thoroughly before using the DVP04TC-S.In order to avoid electric shock, do not touch the terminals or conduct any maintenance while power isapplied to the PLC. Never open the PLC. Only qualified Delta personell should conduct any internalelectrical work on the PLC.This is an OPEN-TYPE device and must be placed in an environment away from high temperatures, highhumidity, exceessive vibration, corrosive gases, liquids, airborne dust, and metallic particles when installedin an enclosure.Do not apply AC power to any of the input/output terminals, this will cause permanent damage to theDVP04TC-S. Do NOT touch terminals when power on.Make sure that the DVP-04TC is properly grounded , to avoid any electromagnetic noise.2 INTRODUCTION2.1 Model Explanation and Peripherals Thank you for choosing DELTA’s DVP Series PLC. The DVP04TC-S allows the connection of fourthermocouple sensors (Type J.K.R.S.T). The DVP04TC-S series can read/write the data by using commandsFROM / TO via DVP-PLC SS/SA/SX/SC MPU program. There are 49 CR (Control Register) in each moduleand 16 bits per register. DVP04TC-S thermocouple sensor can update software version by RS-485. Power supply and mainprocessing units are sold separately. The DVP04TC-S works with both Centigrade and Fahrenheit. The input resolution for Centigrade is 0.1degrees and for Fahrenheit is 0.18 degrees. Nameplate ExplanationP L C m o d e lInput power Supply Spec.Analog Input /Output Module Spec.Barcode, series and versionMODEL¡GPOWER INPUT ¡GTHERMOCOUPLES¡G04 TC -S0 T50 200 01VX.X24Vdc 2WMA D E I N XXXXX XRESOLUTION¡G 14 BITSTYPE J , K , R , S , T Model ExplanationSerial NumberModelS: for SS/SA /SX/SCseries MPUXA: Analog input/output mixed moduleProduct SeriesInput + Output pointsModel typeAD: Analog input moduleDA: Analog output modulePT: Platinum temperature sensors (PT-100)TC: Thermocouple sensors (Type )Production seriesProduction weekProduction year (2005)Production place (Taoyuan)Serial number of versionProduction ModelRT: Resistor Thermocouple(NTC)2.2 Product Profile and Outline90.004.003.00 25.20123460.0056789310L+L-SLDCH1CH2CH3CH41112133.490.0060.003.0014●L+L-L+L-L+L-SLDSLDSLD●●●●●Unit:mm1. Status indicator (Power, RUN and ERROR) 8. Expansion port2. Model Number 9. Expansion Clip3. DIN rail clip 10. DIN rail location (35mm)4. I/O terminals 11. RS-485 Communication port5. I/O point indicator 12. Expansion Clip6. Expansion hole of the expansion unit mountingpins 13. DC Power input7. Specification Label 14. Expansion port2.3 External wiringCH1CH4DC/ DC5VAG+15V-15VAG24+24-SLDL-L+SLDL-L+ConverterSystemClass 3 Grounding(100 of less)terminal ofpower moduleShielded*1*2*3Shielded*1GroundingThermocouple+-100MUXCold-junctionCompensationThermocouple+-Note 1: Use only the wires that are supplied with your thermocouple sensor. Tighten PLC terminal screws to atorque of 1.95 kg-cm (1.7 in-lbs).Note 2: Terminal SLD is a grounding location for noise suppression.Note 3: Please connect terminal of power supply module and terminal of DVP04TC-S thermocouplesensors module to system earth ground.Warning: DO NOT connect wires to the No Connection ( ) terminals. Use copper conductor only, 60/75℃2.4 Terminals of analog moduleDVP04AD-S DVP02DA-S DVP04DA-S DVP04PT-S DVP04TC-S DVP06XA-S DVP08RT-SV+I+COMFGV+I+COMFGI+COMFGV+I+COMFGV+V+I+COMFGV+I+COMFGV+I+COMFGV+I+COMFGI+COMFGV+I+COMFGV+L+L-FGFGI-L+L-I-L+L-FGFGI-L+L-I-L+L-SLGL+L-SLGL+L-SLGL+L-SLGV+I+COMV+I+COMI+COMV+I+COMV+V+I+COMV+I+COML+L-L-L-L+L+L-L+L+L-L-L-L+L+L-L+3 STANDARD SPECIFICATIONS3.1 Function SpecificationsPlatinum Temperature Module (04TC) Centigrade (°C) Fahrenheit (°F)Power supply voltage 24 VDC(20.4VDC~28.8VDC) ( –15%~+20%)Analog input channel 4 channels per moduleSensors type J-type K-type R-type S-type T-type thermocoupleTemperature input rangeJ type : -100℃~700℃K type : -100℃~1000℃R type : -10℃~1700℃S type : -10℃~1700℃T type : -100℃~350℃J type : -148℉~1292℉K type : -148℉~1832℉R type : -14℉~3092℉S type : -14℉~3092℉T type : -148℉~662℉Digital conversion rangeJ type : K-1000~K7000K type : K-1000~K10000R type : K-100~K17000S type : K-100~K17000T type : K-1000~K3500J type : K-1480~K12920K type : K-1480~K18320R type : K-140~K30920S type : K-140~K30920T type : K-1480~K6620Resolution 14 bits(0.1°C) 14 bits(0.18°F)Overall accuracy ±0.5% of full scale of 25°C(77°F), ±1% of full scale during 0~55°C(32~131°F)Response time 350 ms × channelsIsolation Method Isolation between digital and analog circuitry. There is no isolationbetween channels.Digital data format 2’s complement of 16-bit, (13 Significant Bits)Average function Yes (CR#2~CR#5 may be set and the range is K1~K4096)Self diagnostic function YesCommunication mode (RS-485)MODBUS ASCII/RTU Mode. Communication baud rate of 4800 / 9600 /19200 / 38400 / 57600 / 115200. For ASCII mode, date format is 7Bits,even, 1 stop bit (7 E 1). For RTU mode, date format is 8Bits, even, 1 stopbit (8 E 1). The RS-485 is disabled when the DVP04AD-S is connected inseries to an MPU.Connection to a DVP-PLC MPU inseriesWhen DVP04-TC modules are connected to an MPU, the modules arenumbered from 0 – 7. 0 is the closest to the MPU and 7 is the furthest.The Maximum number of modules is 8 modules and they do not occupyany digital I/O points of the MPU.3.2 Other SpecificationPower SpecificationMaximum Power Consumption 2W at 24 VDC (20.4VDC~28.8VDC) ( -15 % ~ +20 %)Environment ConditionEnvironment Condition Follow the DVP-PLC MPU.4 CR (CONTROLLED REGISTER)DVP-04TC platinum temperature sensors ExplanationCRNo.RS-485ParameteraddressLatched Register name b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0#0 H 4096 ○ R Model type System used,. DVP-04TC model code = H 8B#1H 4097○ R/W Thermocouple typeReserved CH4 CH3 CH2 CH1Example: Setting of CH11. b2~b0: set (0,0,0) to use J-type2. b2~b0: set (0,0,1) to use K-type3. b2~b0: set (0,1,0) to use R-type4. b2~b0: set (0,1,1) to use S-type5. b2~b0: set (1,0,0) to use T-type#2 H 4098 ○ R/W CH1 average numberThe number of readings used for “average” temperature on channelsCH1~CH4.Setting range is K1~K4096 and factory setting is K10.#3 H 4099 ○ R/W CH2 average number#4 H 409A ○ R/W CH3 average number#5 H 409B ○ R/W CH4 average number#6 H 409C ╳ R CH1 average degrees(°C)Average degrees for channels CH1~CH4. (unit: 0.1 degrees C)#7 H 409D ╳ R CH2 average degrees(°C)#8 H 409E ╳ R CH3 average degrees(°C)#9 H 409F ╳ R CH4 average degrees(°C)#10 H 40A2 ╳ R CH1 average degrees(°F)Average degrees for channels CH1~CH4. (unit: 0.1 degrees F)#11 H 40A3 ╳ R CH2 average degrees(°F)#12 H 40A4 ╳ R CH3 average degrees(°F)#13 H 40A5 ╳ R CH4 average degrees(°F)#14 H 40A8 ╳ R Present temperature ofCH1 (°C)Present temperature of channels CH1~CH4. (unit: 0.1 degrees C)#15 H 40A9 ╳ R Present temperature ofCH2 (°C)#16 H 40AA ╳ R Present temperature ofCH3 (°C)#17 H 40AB ╳ R Present temperature ofCH4 (°C)#18 Reserved#19 H 40AE ╳ R Present temperature ofCH1 (°F)Present temperature of channels CH1~CH4. (unit: 0.1degrees F)#20 H 40AF ╳ R Present temperature ofCH2 (°F)#21 H 40B0 ╳ R Present temperature ofCH3 (°F)#22 H 40B1 ╳ R Present temperature ofCH4 (°F)#23 Reserved#24 H 40AE ○ R CH1 OFFSET ValueAdjust offset value of channels CH1~CH4. The range is -1000~+1000 andfactory setting is K0. (unit: 0.1 degrees C)#25 H 40AF ○ R CH2 OFFSET Value#26 H 40B0 ○ R CH3 OFFSET Value#27 H 40B1 ○ R CH4 OFFSET Value#28~#29 Reserved#30 H 40B4 ╳ R Error status Data register stores the error status, refer to fault code chart for details.#31 H 40B5 ○ R/W Communication addresssettingRS-485 communication address.Setting range is 01~255 and factory setting is K1#32 H 40B6 ○ R/W Communication baudrate settingCommunication baud rate (4800, 9600, 19200, 38400, 57600 and 115200 bps).b0: 4800 bps (bit/sec).b1: 9600 bps (bit/sec). (factory setting)b2: 19200 bps (bit/sec).b3: 38400 bps (bit/sec).b4: 57600 bps (bit/sec).b5: 115200 bps (bit/sec).b6~b13: Reserved.b14: switch between low bit and high bit of CRC code (only for RTU mode)b15: RTU mode.#33 H 40B7 ○ R/W Reset to factory setting b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0Definition of ERRLEDCH4 CH3 CH2 CH1 |
Related manuals for Delta DVP04TC-S
Delta DVP04PT-S Instruction Sheet
Delta DVP04PT-H Instruction Sheet
Delta DPA Series Instruction Sheet
Delta DPA Series Instruction Sheet
Delta DPB Series Instruction Sheet
Delta DPA Series Instruction Sheet
Delta DPA Series Instruction Sheet
Delta 46-896 Instruction Manual
Delta 36-601 Instruction Manual
Delta 50-2000 Safety Instructions
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine