Dyson Airblade AB04 Wall Mounting Instructions
Also see for Airblade AB04: Filter change guideOwner's manualOwner's manual
x1 x1x2Supplied hardwareknock-outs2 112125345/16”21L NJN.22773 PN.17202-06-01 05.12.08Remove the (6) tamper-proof screws from the unit as illustrated with thetamper proof service tool provided. Make sure to retain the (2) screwinserts from the lower fascia screw holes.WARNING: Use caution when removing casing.The casing may have sharp edges/corners whichmay cut or cause harm.Remove fascia as illustrated.Pry the appropriate metal knock-out from the backplate in one of thelocations pictured. Install electrical entrance fitting into knock-out.Connect the electrical supply using approved flexible or solid conduit andelectrical fittings. Ensure that the flexible or solid conduit and wires are ofsufficient length to make the necessary connection to the backplate andthe terminal block.Select a location that will allow accessibility to the Dyson AirbladeTM handdryer and proper clearance from surroundings and floor. Make sure that theunit is installed in compliance with all building codes and/or regulations.Position the mounting template provided on the wall where the DysonAirbladeTM hand dryer is to be installed. Recommended heights are shown,but may need to be adjusted for each individual installation. Securely fastenthe mounting bracket to the wall with a minimum anchor size of 0.25".Hang the unit on the secured mounting bracket as illustrated.Securely fasten the four remaining anchors to the wall.Recommended minimum anchor size of 0.25".Carefully replace the fascia as illustrated. ATTENTION!: Do not overtighten screws as this may damage the fascia.Make sure that the clips on the top of the front fascia are seated correctly and that the fascia is mounted flush before tightening screws.1. Insert and tighten the (2) anti-tamper screws into the middle of front fascia as illustrated.2. Place a mounting nut insert underneath the lower fascia and slide into mounting hole with a 5/16" allen key, then insert and handtighten the anti-tamper screw. Finish tightening with the supplied tamper proof service tool. Repeat process for the opposite lower side.3 & 4. Insert the filter cover panel, and then (2) anti-tamper screws. Tighten with supplied tool.5. Test unit for correct operation before inserting the (2) screw covers.WARNING: Risk of electric shock!Secure the Line, Ground and Neutral wires into the proper terminal blocklocations. Verify connections are correct before proceeding.AB04 (120V)Dyson Airblade TMhand dryer wall mounting instructionsIf you have any questions on the installation please call ourDyson Helpline toll free at 1-888-DYSON-AB (1-888-39766-22)Important safety information – Read before proceeding further.Installation work and electrical wiring must be done by qualified person(s) in accordance with allapplicable codes and standards, including fire-rated construction.WARNING: Before beginning any installation work you must confirm the following:Make sure that the electrical supply has been disconnected or switched off before attempting installation to avoid therisk of electrical shock or electrocution.Ensure no pipe work (gas, water, air) or electrical cables, wires or ductwork are located directly behind the drilling area.WARNING: Risk of electric shock! If casing is removed or handled improperly the internal componentsof the Dyson AirbladeTMhand dryer may cause harm or become permanently damaged.CAUTION: To reduce the risk of electric shock, do not expose the internal mechanism/components ofthis unit to rain or moisture.Check that the electrical supply will correspond with the rating plate located on the bottom of the unit.If the unit is connected to any electrical supply other than that stated on the rating plate of the unit, permanent damageor improper/unsafe operation of the Dyson AirbladeTMhand dryer may result.All wiring and electrical work must be done by a qualified electrician in accordance with all federal, state and localapplicable codes and standards, including fire-rated construction.A means for all pole disconnection must be incorporated in the fixed wiring to the appliance in accordance with localwiring regulations.The Dyson AirbladeTMhand dryer must be grounded properly.The instructions herein must be read carefully before attempting to install the Dyson AirbladeTMhand dryer. Read andretain for future reference.Failure to accurately follow the instructions may result in the incorrect operation of the Dyson AirbladeTMhand dryer,damage to property and/or personal injury.Dyson will not be held liable for any damages to property or personal injury as a result of failure to comply with theinstructions contained herein.Failure to follow these instructions will invalidate the warranty of this product. Please refer to the Owner’s Manual fordetails of the warranty.The Dyson AirbladeTM hand dryer requires a 15 amp circuit breaker on a dedicated line.28.75” adult male height25.75” adult female height21.75” child/wheelchair user heightHeight measurements are from the floor39” adult male height36” adult female height32” child/wheelchair user heightHeight measurements are from the floor3.15” 3.15”Electrical supply location optionsThe Dyson AirbladeTMhand dryer requires a 15 amp circuit breaker on a dedicated lineDrill hole of at least 2” diameter65 7 84321 |
Related manuals for Dyson Airblade AB04
Dyson Airblade Series Installation Instructions Manual
Dyson Airblade 1A Installation Instructions And Maintenance Manual
Dyson Airblade 9KJ Installation Instructions And Maintenance Manual
Dyson Airblade WD06 Installation Drawings
Dyson Airblade HU02 Installation Manual
Dyson airblade AB02 Specification
Dyson Airblade Wash+Dry WD04 Care & Cleaning
Dyson Airblade Care & Cleaning
Dyson Airblade AB01 Owner's Manual
Dyson Airblade AB02 Owner's Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine