Eaton ELC-GP04 Instruction Sheet
Also see for ELC-GP04: Catalog
IL05003006E.pdfELC-GP04GRAPHIC PANEL SERIESInstruction SheetWARNING• DANGER - DC input power must be disconnected before any maintenance. Do not connect ordisconnect wires and connectors while power is applied to the circuit. Maintenance must beperformed by qualified technicians.• DANGER - The ELC-GP04 requires 24VDC input power. The 24VDC input power should not beconnected to the RS-485 communication port. The unit may be destroyed or can’t be repaired ifthe input power is improperly applied. Please always check the correctly input power wiringbefore apply power.• DANGER - An electrical charge will remain on the DC-link capacitors for 1 minute after powerhas been removed. Do not conduct any wiring or investigation on the ELC-GP04 until 1 minuteafter power has been removed. Do NOT touch terminals when power on.• CAUTION - Always ground the ELC-GP04 by using the grounding terminal. Not only this acts asa safety, but also filter out electrical noise. The ground method must comply with the laws of thecountry where the unit is to be installed.• CAUTION - ELC-GP04 may be damaged if the fixed support (shipped with the pack) is adjustedtoo tight.• Please carefully read this instruction before using the ELC-GP04.• The ELC-GP04 display panel is waterproof. But please prevent grease, corrosive liquids andsharp objects from contacting the ELC-GP04.• Battery replacement: please use UL component type: CR2032 lithium battery (NOTE: RTCshould be reset after changing battery).• Do not disconnect while circuit is live unless area is known to be non-hazardous.• This equipment is suitable for use in Class I, Division 2, Groups A, B, C, D or Non-HazardousLocations only.• Explosion Hazard – Substitution of components may impair suitability for class I, Division 2.• Explosion Hazard – Do not disconnect equipment unless power has been switched off or thearea is known to be Non – Hazardous.• Power, input and output (I/O) wiring must all be in accordance with Class I, Division 2 wiringmethods, Article 501-4 (b) of the National Electrical Code, NEPA 70,or as specified in Section18-152 of the Canadian Electrical Code for units installed within Canada, and in accordancewith that location’s authority.1 INTRODUCTION1.1 Model ExplanationThank you for choosing Eaton Logic Controller (ELC) GP Series. The features of ELC-GP04 are:resolution is 128*64, display 8*4 Chinese characters (max.) and multi-language support. It is built-intwo communication ports (RS-232 and RS-485/RS-422, can be used simultaneously), and Built-inRTC and communication/alarm indication LED.Possess extension slot for ELC-GPXFERMOD to copy settings and programs rapidly and savedownload time. Built-in variety objects to meet your requirement.1.2 Outline1.3 Panel Function ExplanationPANEL COMPONENT EXPLANATIONAlarm Indication LED(RED)Status 1: When power is on, the LED will flash three times slowly.Status 2: When there is an abnormal situation, the LED will flash quickly along with analarm sound.RS-232 Indication LED(Yellow) It will be flashing when transmitting program and communicating by using RS-232.RS-485/RS-422Indication LED (Green) It will be flashing when communicating by using RS-485/RS-422.LCD Display Area Liquid Crystal Module display area used to display current program state.Escape/Exit Used to cancel an incorrect input, or to Exit a programming step.Arrow KeysUP/Pg Up: Used to increase the value or move up one page.Pg Dn/DOWN: Used to decrease the value or move down one page.Left: Left direction key. (move curser to left)Right: Right direction key. (move cursor to right)Shift Key Used to select keys F5, F6, F7, F8, F9.Enter Key Used to input a value or accept a programming command.Function KeysF0/F5: They are used to be constant 0 (F0) and 5 (Shift+F0) when they are in systemmenu and user can define the functions separately when they are in user page.F1/F6: They are used to be constant 1 (F1) and 6 (Shift+F1) when they are in systemmenu and user can define the functions separately when they are in user page.F2/F7: They are used to be constant 2 (F2) and 7 (Shift+F2) when they are in systemmenu and user can define the functions separately when they are in user page.F3/F8: They are used to be constant 3 (F3) and 8 (Shift+F3) when they are in systemmenu and user can define the functions separately when they are in user page.F4/F9: They are used to be constant 4 (F4) and 9 (Shift+F4) when they are in systemmenu and user can define the functions separately when they are in user page.1.4 Back PanelBATTERYSWITCH ORRS-485/4225-PIN terminals:Wire gauge: 12-24 AWGTorque: 4.5 lb.-inch1.5 DimensionFront panel (unit: mm [inch]) Right side diagram (unit: mm [inch])97.00[3.82]147.00 [5.79]85.00[3.35]Vertical view (Unit: mm)1.6 InstallationMounting ELC-GP04 into the opening is done by carefully fitting the unit into the opening andpressing firmly on all four corners. You could fix it by using the fixed support packaged withELC-GP04.Warning: If you turn the screw exceeds torque: 4-5(kg-cm), ELC-GP04 may be damaged.(Note:the flat surface should be a Type 4 “Indoor Use Only” enclosure or equivalent.)Please leave sufficient space (more than 50mm) around the unit for heat dissipation.Thickness:0.5~9.0mm50mm50mmMounting dimension (unit: mm [inch])Thickness Range 0.5~9mm135~136.5[5.31~5.37]85[3.35]2 SPECIFICATION2.1 Electrical SpecificationITEM ELC-GP04Function Key/Digital Key F0~F4, ESC, SHIFT, ENTER and ARROW keysExternal Input Power 24VDC (-15%~20%) 3.5W MAX.Memory Capacity 256K ByteCPU Hitachi HD64F3064FRAM of System 32K ByteCommunication Interface COM1: RS232; COM2: RS485/RS422(See Section 6)Waterproof Class of Front Panel IP65/NEMA4/UL Type 4 (indoor use)Environment Condition 0~50℃, relative humidity 20-90% RH (non-condensing)Storage Temperature for Hardware -20~60℃Vibration5Hz≦f<9Hz = Continuous: 1.75mm / Occasional: 3.5mm9Hz≦f≦150Hz = Continuous: 0.5g / Occasional: 1.0gImpact 15g peak, 11ms duration, half-sine, three shocks in each direction peraxis, on 3 mutually perpendicular axes (total of 18 shocks)Radiated Emission CISPR11, Class AElectrostatic Discharge Immunity EN61000-4-2Radiated Immunity EN61000-4-3Electrical Fast Transient EN61000-4-4Weight/Dimension 0.24kg/147×97×35.5mm (Width × Height × Deep)Cooling Method Natural Air CoolingTemperature Code T6Hazardous Location rating Class I, Division 2, Group A, B, C, and D2.2 Function SpecificationITEM ELC-GP04Display ScreenScreen STN-LCDColor MonochromaticBacklightThe back-light automatic turn off time is 1~99 minutes(0 = do not turn off)(back-light life is about 50 thousand hours at 25℃)Resolution 128X64 PointsDisplay Range 72mm (W) X 40mm (H); 3.00” (diagonal preferred)Contrast Adjustment 10-step contrast adjustment |
Related manuals for Eaton ELC-GP04
Eaton DX-NET-SWD3 Instruction Leaflet
Eaton MTL5501-SR Instruction Manual
Eaton C445UM Series Instruction Leaflet
Eaton XV-303 Series Instruction Leaflet
Eaton NZM-XDMI612 Instruction Leaflet
Eaton RMQ-M1C-ASI Instruction Leaflet
Eaton Crouse-hinds series Instruction Manual
Eaton Crouse-Hinds Series Instruction Manual
Eaton xComfort CKOZ-00/03 Assembly Instructions Manual
Eaton RI-2 Installation Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine