PACSystems* RX3iIC695ETM001-HWGFK-2332X Ethernet Interface ModuleMarch 2016The Ethernet Interface Module, IC695ETM001, connects aPACSystems RX3i controller to an Ethernet network. It enablesthe RX3i controller to communicate with other PACSystemsequipment and with Series 90 and VersaMax controllers. TheEthernet Interface provides Transmission Control Protocol andInternet Protocol (TCP/IP) communications with other controlsystems, host computers running the Host CommunicationsToolkit or programmer software, and computers running theTCP/IP version of the programming software. Thesecommunications use the Service Request Transport Protocol(SRTP), Modbus TCP, and Ethernet Global Data (EGD) protocolsover a four-layer TCP/IP (Internet) stack.Features of the RX3i Ethernet Interface include:▪ Full programming and configuration services. Firmwareupgrades from the RX3i CPU using the WinLoadersoftware utility, which is supplied with updates to theEthernet Interface software.▪ Periodic data exchange using Ethernet Global Data (EGD).▪ EGD Commands to read and write controller and EGDexchange memory over the network.▪ TCP/IP communication services using SRTP.▪ Support for SRTP Channels, Modbus/TCP Server, andModbus/TCP Client▪ Built-in Station Manager for on-line supervisory access tothe Ethernet Interface. Dedicated Station Manager port.▪ Two auto-sensing 10Base T / 100Base TX RJ-45 shieldedtwisted-pair Ethernet ports for direct connection to eithera 10BaseT or 100BaseTX IEEE 802.3 network without an external transceiver. There is only one interface to thenetwork (only one Ethernet MAC address and only one IP address).▪ Internal network switch with Auto negotiate, Sense, Speed, and crossover detection.▪ Recessed Ethernet Restart pushbutton permits manually restarting the Ethernet firmware without power cyclingthe system.▪ LEDs: Ethernet OK, LAN OK, Log Empty, individual port activity and speed LEDs.▪ Configurable stand-alone Redundant IP addressing, which allows a single IP address to be assigned tocorresponding Ethernet modules in two different controllers. The Redundant IP address is configured inaddition to the normal unique IP address of each Ethernet module. Under application logic control, only theEthernet module in the active unit can use the Redundant IP address.▪ Time synchronization to SNTP Time Server on Ethernet network (when used with Release 5.00 or later CPUmodule).* Indicates a trademark of General Electric Company and/or its subsidiaries. All other trademarks are the property of theirrespective owners.Copyright © 2013- 2016 by General Electric Company. All Rights Reserved