GE ZGU364NRP Manual
36" and 48" GAS RANGETOPS36" Natural Gas Models: ZGU364NDP, ZGU364NRP,ZGU366NP36" LP Gas Models: ZGU364LDP, ZGU364LRP, ZGU366LP48" Natural Gas Models: ZGU484NGP, ZGU486NDP,ZGU486NRP48" LP Gas Models: ZGU484LGP, ZGU486LDP,ZGU486LRPIMPORTANT NOTICE: This information is intended for useby persons possessing adequate backgrounds of electrical,electronic, gas and mechanical experience. Any attempt to repaira major appliance may result in personal injury and propertydamage. The manufacturer or seller cannot be responsiblefor the interpretation of this information, nor can it assumeany liability in connection with its use.WARNING: DISCONNECT POWER BEFORE SERVICINGDisconnect the rangetop electrical power supply at the householddistribution panel by removing the fuse or switching off the circuitbreaker.Shut off the gas supply in the gas line by closing the manualshut-off valve.Shut off the rangetop gas supply by closing the rangetop shut-offvalve located beneath the rangetop.IMPORTANT: Reconnect all grounding devices. All parts of thisappliance capable of conducting electrical current are grounded.If grounding wires, screws, straps, clips, nuts or washers usedto complete a path to ground are removed for service, they mustbe returned to their original positions and properly fastened.CAUTION — The rangetop, as shipped fromthe factory, is set for use with its intended gas. If you wishto use your rangetop with the alternate gas, you must firstreplace the orifices and convert the pressure regulator.GAS CONVERSION KITThe gas conversion kit is located inside the rangetop insulationcover.HIGH ALTITUDE KITFor operation from 3,000 to 7,000 feet, order WB28K10553Conversion Kit. This kit includes orifices for both LP and Natural gasoperation.CONTROL PANEL REMOVALSlide the rangetop forward about 4". Pull the surface knobs offand remove the screws from each bezel. Remove the screws fromthe control panel face.Remove the screws from the bottom of the control panel and fromthe top (inside flanges, on each side, on the back side of the panel).Remove the screws from the rear face of the control panel oneach side.ACCENT LIGHTING REPLACEMENTRemove the control panel. See the CONTROL PANEL REMOVALsection.Loosen the accent lighting module’s screw, slide out and replace.SURFACE KNOB INDICATOR LIGHT REPLACEMENTRemove the control panel. See the CONTROL PANEL REMOVALsection. Find the indicator light on top of the gas valve, removethe attached screw and replace.GAS MANIFOLD AND VALVES REPLACEMENTRefer to the Service Manual for replacement procedure.SPARK MODULE REPLACEMENT1. Slide the rangetop forward about 4".2. Remove the control panel. See the CONTROL PANEL REMOVALsection.3. Remove the screws from the rear trim and the left side trim.All screws are on the inside, facing the burners.4. Remove the left grates and left grate frame. Remove surfaceburners by removing all screws, but keep the outside burnerscrews separate from the inside burner screws so they canbe easily replaced. Remove the burner pan, burner insulationand spark module cover. Disconnect the igniter wires by pullingthem off of the connector pins.GRILL IGNITER REPLACEMENTRemove the grill cover, grate,grate frame and radiant baffle.Remove the screws from eachside of the pan surround andremove the pan surround.Remove the screws fromthe igniter and pull the igniterconnector from the opening.Disconnect the connector pinand replace the igniter. Pushthe igniter connector backinto the opening and replaceall parts.GRIDDLE IGNITER REPLACEMENTLift off the griddle flue cover. Remove the 2 inside clamping screws.NOTE: Remove the 2 screws positioned on the inside only. Do not removethe outermost screws—they are for leveling the griddle.Slide the griddle toward the rear and out of the hold-down tabs alongthe bottom front.CAREFULLY lift and hold the griddle. A thermostat capillary is routedthrough a clip. Gently lift the griddle to one side and slip the capillary outof the clip. Do not disconnect or pull on the capillary. Gently lay the griddleaside.Remove the 2 burner hold-down screws at the rear of the burnerto loosen the burner. Remove the screws attaching the igniter. Pullthe igniter connector from the opening, disconnect the pin connectionand replace the igniter. Route the capillary back into the clip. Pushthe excess capillary back through the opening. Push the igniterconnector back into the opening and replace all parts.GRIDDLE HIGH LIMIT SWITCHThis switch is located at the front of the griddle box inside the burner box.Refer to the Service Manual for further information.INCOMINGGAS TYPE PRESSURE TO PRESSUREREGULATOR REGULATOR OUTPUTNatural 6.0″ to 14.0″ W.C.P. 5.0″ W.C.P.L.P. 11″ to 14″ W.C.P. 10.0″ W.C.P.GAS SUPPLY REQUIREMENTSControl PanelBezelsSurface KnobsGratesGrate FrameSurface BurnersSpark Module CoverBurner PanBurner InsulationGrill GrateGrill GrateFrameRadiantBafflePanSurroundGriddle Flue CoverCapillaryIgniterLeveling ScrewsClamping ScrewsSlide back griddleand lift frontMODELNUMBERSZGU364NDP, ZGU364NRP, ZGU366NPZGU364LDP, ZGU364LRP, ZGU366LPZGU484NGP, ZGU486NDP, ZGU486NRPZGU484LGP, ZGU486LDP, ZGU486LRPIMPORTANTSERVICE INFORMATIONDO NOT DISCARD31-14752 04-08 JRPrinted in MexicoTAPE AREASet ScrewLoosen |
Related manuals for GE ZGU364LDP
GE ZGU366NPSS Owner's Manual
GE ZGU364 Installation Instructions Manual
GE JCS630 Manual
GE JGP650 Manual
GE Monogram ZGU364NRP7SS Installation Instructions Manual
GE ZGU364LDP2SS Installation Instructions Manual
GE 36” Owner's Manual
GE PLU612 Owner's Manual
GE PHS930 Owner's Manual
GE CCHS995 Owner's Manual
manualsdatabase
Your AI-powered manual search engine