Gardner Bender SDT-3 Operating Instructions Manual
Also see for CAM-10: Operating instructionsOperating instructionsQuick start guide
SPECIFICATIONSBatteries: CAM-10 Use 2 LR44 button cell batteriesOperating Range: 50-600 VAC, 50-60 HzVoltage Indicators: Audible & Visual AlertOperating Temperature: 32-122°F (0-50°C)Storage Temperature: 0°F (-18°C) to 156°F (70°C)Humidity: 80% RH maximum below 86˚F(30˚C),50% RH maximum above 86°F (30°C)Altitude: Up to 6561 feet (2000 meters)Safety: For indoor use and in accordance with overvoltage category III, Pollution degree 2Intended Use: Non-contact AC voltage detectionSerial No: See interior of battery coverCLEANINGUse clean, dry cloth. Do not use any type of solvent.BEFORE USEREAD ALL OPERATING INSTRUCTIONS BEFORE USE. FORINTENDED USE ONLY. Protection provided by this productmay be impaired if used with accessories not provided by themanufacture or if used as in a manner other than specified within.WARNING: To be used by trained person only. High voltage ACand DC circuits are dangerous. Use extreme caution and use asintended when testing potentially live circuits. Risk of Electrocution.WARNING: This product should be used to test or detectinsulated wires and terminals but should not be used tocontact Live Circuits. This tester will not detect voltage in wiresthat are electrically shielded by metal conduit or groundedenclosures. Risk of Electrocution.OPERATIONBefore use, test the batteries of the CAM-10 tester by pressingthe button on the tester marked PRESS. A momentary audibletone and flash of the light are an indication that the unit is working.WARNING: Always test on known live circuit before use.To test for voltage:1. Hold the screwdriver with your thumb on theCAM-10 tester button marked PRESS,keeping hands and fingers well awayfrom the sensor (red end).2. Press down and hold the test buttonon the tester. A momentary alertindicates the unit is working.3. Place the sensor (red end) nearthe wire or device to be tested.Maintain a minimum distance of0.5mm from contacting the wireor device to be tested. If voltagegreater than 50 VAC is present, the testerlight and tone will activate rhythmically at10 to 15 cycles second.To detach the tester from the screwdriver, apply force to thetester near the Gardner Bender logo and slide the tester fromthe holding slot. The tester can be used to test for voltage afterit is detached per instructions within. Hold the tester as shown,keeping hands and fingers well away from the sensor (red end).CAM-10 BATTERY REPLACEMENTRemove the Phillips® head screw from the bottom of the CAM-10tester. Lift off the battery cover from the top of the tester. Insert2 LR44 batteries in the orientation indicated on the side of thebattery cover. Replace cover and screw.ESPECIFICACIONESBaterías: El modelo CAM-10 usa 2 baterías de botón LR44Rango operativo: 50-600 VCA, 50-60 HzIndicadores de voltaje: Alerta sonora y visualTemperatura operativa: 0-50°CHumedad: 80% HR máxima, 50% HR máxima sobre 30°CAltitud: Hasta 2000 metrosSeguridad: Para uso en interiores y conforme a la categoría IIIde sobrevoltajeGrado de contaminación 2. IEC 529, IEC 1010Uso previsto: Detección de voltaje CA sin contactoLIMPIEZAUse un paño limpio y seco. No use ningún tipo de solvente.ANTES DEL USOLEA TODAS LAS INSTRUCCIONES OPERATIVAS ANTES DELUSO. SÓLO PARA EL USO PREVISTO.ADVERTENCIA: Son peligrosos los circuitos de CA y CC dealto voltaje. Tenga sumo cuidado y utilice de la manera previstaal probar circuitos potencialmente energizados. Riesgo deelectrocución.ADVERTENCIA: Este probador no detecta el voltaje en cablesque tienen blindaje eléctrico mediante portacables de metal ocierres puestos a tierra. Riesgo de electrocución.OPERACIÓNAntes de usar, pruebe las baterías del probadorCAM-10 oprimiendo el botón en el probador que está marcadoPRESS. Un tono audible momentáneo y un destello de luz sonindicaciones de que la unidad está funcionando.ADVERTENCIA: Siempre pruebe en un circuitoenergizado conocido antes de usar.Para probar el voltaje:1. Sostenga el destornillador con el pulgaren el botón del probador CAM-10marcado PRESS, manteniendo lasmanos y los dedos bien alejadosdel sensor (extremo rojo).2. Oprima y mantenga así el botónde prueba en el probador.Limited Lifetime Warranty limited solely to repair or replacement; no warranty ormerchantability or fitness for a particular purpose. Product is warrantied to be freeof defects in materials and workmanship for the normal life of the product. In noevent shall Gardner Bender be liable for incidental or consequential damage.GBSDT-3, SDT-6, SDT-10ScrewdriversCAM-10Non-contact Voltage TesterOPERATINGINSTRUCTIONSPatents PendingSDT-3, SDT-6, SDT-10DestornilladoresCAM-10Probador de voltaje sin contactoINSTRUCCIONESOPERATIVASPatentes pendientesGBSYMBOLSThis equipment has double insulation with respect to live circuitsAttention, consult the accompanying documents!! |
manualsdatabase
Your AI-powered manual search engine