Gemini GEN-PACK H-W 12M6-42000 Instructions Manual
INTRODUCTIONThe GEN-PACK H-W™ is a half wave regenerative SCR drive for intermittent operation of permanent magnet motors in asingle or bi-directional mode. It provides forward and reverse torque in both directions, maintains constant speed withoverhauling loads and provides rapid deceleration, reversing, and controlled regenerative braking.Feedback is jumper selectable from either armature voltage or from a DC tachometer generator with fast response in bothfeedback modes.Specifications:Speed Range: 50:1Overload Capacity: 150% for 60 secondsMaximum Speed Adjustment: 50-110%Output AmpsModel Mounting Input Voltage Output V. Range HP Cont. Max.12M6-42000 Open chassis 115/230 VAC 0 to 90/180VDC 1@115VAC, 2@230V 10 2012M6-42001 NEMA 12 Encl. 115/230 0 to 90/180 1@115VAC, 2@230V 10 20GENERALThese instructions provide basic information for installation and adjustment. Please contact Gemini Corp. if further informationis necessary. It is possible to damage the drive through misuse or misapplication. Please read this material thoroughly beforeproceeding with installation.Unpack the equipment noting any shortages or damaged equipment. Immediately notify the carrier of any damage. Store inclean, dry location if the product is not used immediately. The relative humidity should not exceed 95%, non-condensing.Caution: This control provides half wave rectified power to the DC motor. Peak currents result in an RMS equivalentcurrent that may be considerably higher than with a full wave source of power. For this reason it may be necessary toderate the motor to avoid overheating. Consult with the motor manufacturer and Gemini for specific information.INSTALLATIONCarefully mount the chassis or enclosure allowing clearances for access, air flow and conduit entry. The environment should befree of vibration and contaminants. The operating temperature range for the Gemini drive is 32 to 104 degrees Fahrenheit (0-40C). Since the drive produces heat, utilize a source of cooling, such as a fan, when the ambient temperature approaches 104degrees.WARNING: Do not drill or file the enclosure or chassis when the controller is installed, as metalparticles can cause shorts and damage.WIRING1. Input Wiringa. Since the control will operate on either 115 or 230VAC, jumper(s) must be applied to obtain the required voltage. For115VAC input, place a jumper between terminals “H1” and “H3”, and another jumper between terminals “H2” and “H4”. For230VAC input, place a jumper between “H3” and “H2”. Connect the AC line to terminals “L1” and “L2” (note wiringdiagram). Terminals “S1” and “S2” are used as wiring points when a line switch is used for ON-OFF control. Wire one pole ofa two pole switch to connect between terminals “L1” and “S2”. Wire the other pole to connect “L2” and “S2”.If required, the chassis may be grounded at one of the unused holes. Input wire size must be in compliance with the NationalElectrical Code and all local codes and restrictions.WARNING: Do not connect line power to the motor terminal connections.b. Note the jumper terminals on the top circuit board. Install a small shunt type jumper at position “K” for a 115VAC input and4 Quadrant SCR GEN-PACK H-W DC Drive InstructionsModels 12M6-42000 and 12M6-42001 |
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine