Haier HW-07LN03 Operation Manual
Also see for HW-07LN03: Operation manualOperation manualOperation manualService manualOperation manual
Contents |
1234 HINTSCompressor won’t start in FAN mode ,onlyfan motor will run at selected speed.It is advisable not to keep vertical flap at downward position for a long time in COOL or FANmode,otherwise , condensate water might occur.Don't move the horizontal flap with hand in order to avoid the vertical flap abnormal, using theremote controller to adjust the move of vertical flap.HW-07LN03 HW-09LN03 HW-12LN03HW-09C2 HW-12C1HW-12LNA03 HW-09LN13 HW-12LN13HW-09CA2 HW-12CA2Please read this operation manual before using the air conditionerPlease keep it attentively0010515219OPERATION MANUALApplicable ambient temperature range:ROOM AIR CONDITIONEROPERATION CONDITIONSHW-09LNA03D.B :Dry Bulb Temperature W.B :Wet Bulb TemperatureAIR CONDITIONER OPERATION2D.B W.B D.B W.B D.B W.B D.B W.BMax.Temperture: 32℃ 23℃ 43℃ 26℃ 32℃ 23℃ 43℃ 28℃Min.Temperture: 18℃ 14℃ 18℃ / 18℃ 14℃ 18℃ /CoolingT1 T4Indoor Outdoor Indoor OutdoorIt is advisable not to keep vertical flap at downward position for a long time in COOL mode,otherwise , condensate water might occur.Don't move the horizontal flap with hand in order to avoid the vertical flap abnormal, using theremote controller to adjust the move of vertical flap.HW-07LN03 HW-09LN03 HW-12LN03HW-09C2 HW-12C1HW-12LNA03 HW-09LN13 HW-12LN13HW-09CA2 HW-12CA2OPERATION MANUALROOM AIR CONDITIONERHW-09LNA03HINTSCompressor won’t start in FAN mode ,onlyfan motor will run at selected speed.CAUTIONThe compressor may cycle for 10 minutes on and 6 minutes off in Dehumid mode.Air blown out will be very cold at relatively low room temp..Machine bodyFront panelAir inlet(indoor side)Air outlet(indoor side)Air inlet(outdoor side)Control panelAir filter (inside)Machine bodyPower plugTake out the air filterClean the filterHumpWhen dirt accumulates on air filter, aircirculation will be blocked, which causespoor cooling. It is advisable to clean airfilter every two weeks for longer operation.1.Press the concave parts onboth sides at the lower part ofair inlet grille to open the airinlet grille.2.Hold the hump of filter meshwith fingers (as illustrated) andtake it out.1.Gently flap the dirt off the air filter.2.Carefully wash air filter in warm water(below 40°C).Toobtain better cleaning effect,soap water or neutral detergentmay be used.3.Flush air filter carefully with clean water after removingdirt.Let it dry completely.CAUTIONTo protect unit system, don’t restart until3 minutes have elapsed.If the unit has been running under largehumidity for a long time, dew might occurat outlet grille.CAUTIONPART INDENTIFICATIONRemote controller Controll panelCooling operationFan operation1.Press MODE button.For each press,operationmode changes as follows:When the COOL display light bright,A/C will beworking under the cooling function.2.Select temp.setting, by using “ ” or“ ”button.“ ” Each press will increase temp. setting by 1.“ ” Each press will decrease temp. setting by 1.3.If you choose the FAN SPEED mode you can runthe fan in one of the 2 speeds: HI or LO.Change air flow direction if necessary.1.POWERPress it to start unit and press it again to stop.2.MODE:Used to select operation mode:FAN COOL DEHUM3.FANSPEED:Used to select desired fan speed :HIGH or LOW.4.TIMERUsed for TIMER start or stop.5.TEMP.or TIME setUsed to set TIME or TEMP.setting.6.E-SENERGY SAVER7.SWINGUsed to activate the vertical louver .This will giveyou an even airflow througout the room.8.ENERGY SAVER9.TEMP./TIME displayIn some days you may want to run the“Fan”function.1.Press MODE button.When the FAN display light bright, A/C will beworking under the fan function.2.Fan speed selection:Here the fan runs only at Hi or Lo speed.Change air flow direction if necessaryTimer operationWith this function, unit will start or stop at thetime you want.1.Start unit and select desired operation mode.2.Select Timer functionTimer On or Off stop mode is used to preset orshut off your unit in advance .You can program this up to 24 hours inadvance. You can use the Timer in 3 functioni.e Cool Dehumid or Fan only. Selecteddesired mode. (TIMER On or Off stop )Timer OnUnit must be on to set the timer. Unit will shutdown automatically after it accepts the settingin 5 seconds. Use this mode to preset the starttime of the unit 24 hours in advance .a) Press “On” of remote controller or “TIMER”of control panel,LED display will show “01”.(Electrify for the first time)b) Set desired number by pressing the( )pad of the Temp/Time buttons. One foreach hour . If you passed the desired time usethe ( ) pad key to lower the selection.Timer OffUnit must be running to set the timer off. Usethis to preset the time you would like the unit toshut off.a) Press “off” of remote controller or “TIMER”ofcontrol panel,LED display will show“01”.(Electrify for the first time)b) Set desired number by pressing the( ) pad of he Temp/Time buttons. One foreach hour . If you passed the desired time usethe ( ) pad key to lower the selection.When using the timer the unit will use/revert tothe last A/C , fan settings when activated . Thetimer must be reset every time you choose touse it .OPENCLOSEThe ventilation lever must beCLOSE position in order tomaintain the best coolingconditions. When fresh air isnecessary in the room, set theventilation lever to the OPENposition. The damper isopened and room air isexhausted.Airflow Direction VaneThe horizontal air direction isadjusted by setting theAUTO SWING on.The Vertical Airflow DirectionVane is manually controlledby positioning the vane todischarge the airupward,downward or straightout.Vertical airflow directionVentilationAir filter cleaning2 Airflow Direction3Ventilation1Do not raise the front panelany higher than 70 ° to theunit or damage to the tabsmay occur.CAUTIONBefore cleaning, turn offthe powerCONTENTSSafety precautions....................1Air conditioner operation ..........2Care and Maintenance ............5Air conditioner installation........6Troubleshooting.......................8SAFETY PRECAUTION1Do not install,remove and reinstall the unit yourself. Improper installation may causeleakage,electric shock or fire.Please engage an authorized dealer or specialist for the installation work.The room air conditioner must be earthed.Do not touch or operate with wet hands.Do not turn on the unit by inserting the power plug.Do not switch off the unit by pulling outthe power plug.Do not insert sticks,fingers or other objects into the unit.If the supply cord is damaged, it must be replaced by the manufacturer or its service agentor a similar qualified person.After installation, the power plug should be easily reached.The wiring method should be in line with the local wiring standard.CAUTION70 °DEHUMID modeIf you need to only remove the moisture press theDehumind button.1.Press MODE button.When the DEHUM display light bright, A/C will beworking under the dehumidify function.2.Select temp.setting, by using “ ” or“ ” button.“ ” Each press will increase temp. setting by 1°C.“ ” Each press will decrease temp. setting by 1°C.3.If you choose the FAN SPEED mode you can runthe fan in one of the 2 speeds: HI or LO.Air conditioner is running under displayed fan speed.In DRY mode, when room temperature becomeslower than temp. setting +2°C, unit will intermittentlyat LOW speed regardless of FAN setting.Change air folw direction if necessary.ENERGY SAVER operation1.Select operation modePress MODE button. Then select COOL operationSaving energy function only can be used when A/Cworking on cooling condition.2. ENERGY SAVER selectionWhen this feature is “On”, the fan will shut off threeminutes after the compressor cycles off. This willreduce energy consumption and noise. When thecompressor turns back on, the fan will turn on at thesame time. In the “Off” position , the fan will not shutoff when the compressor cycles off.Remote controller’s operationWhen in use, put the signal transmission headdirectly to the receiver hole on the indoor unit.Don’t throw the controller, prevent it from beingdamaged.When electronic-started type fluorescent lampor change-over type fluorescent lamp orwireless telephone is installed in the room, thereceiver is apt to be disturbed in receiving thesignals so the distance to the indoor unit shouldbe shorter.123456712 3 9 4 7 58 |
Related manuals for Haier HW-07LN03
Haier HW-07LN03 Operation Manual
Haier HW-07LN03 Operation Manual
Haier HW-07LN03 Operation Manual
Haier HW-07LF03 Operation Manual
Haier HW-07LM03 Operation Manual
Haier HW-07LM03 Operation Manual
Haier HW-07LN03 - annexe 1 Operation Manual
Haier HW-09CN03 Operation Manual
Haier HW-07CK03 Operation Manual
Haier HW-09CV03 Operation Manual
manualsdatabase
Your AI-powered manual search engine