Adjustment for FX-2463 (IC-F11)ADJUSTMENTAdjustment No. Adjustment Condition & Tuning Value Ref.No. CK.PointPreparation Connect the transceiver by cloning cable(OPC-478) to a PC (IBM compatible) andboot up the cloning software.Check points Be sure to use a tester with more than 50ohm/V internal resistance when makingeach test.Lock Voltage Set the transceiver to the highestAdjustment band frequency on the TX condition, and setthe LV voltage as follows by means ofspreadable coil L16.Adj. Freq. Highest. Band Freq.TX Side 4.0V 4.0V L16Lock Voltage Set the transceiver to the lowestCheck band frequency, and check that each ofthe LV voltage is within as follows.Adj. Freq. Lowest Band Freq.RX Side 0.8V~1.8V 0.8V-1.8V LVTX Side 0.8V~1.8V 0.8V-1.8VFrequency Connect a power meter or attenuator to theAdjustment antenna terminal. Loose coupling the ANTand frequency counter.Set the transceiver to near the TX greatesthigh band frequency and set the unit to TX.Use adjustment software to adjust the TXfrequency to the values below.Set Frequency Center Freq. ± 500 Hz ±500Hz Adj.Soft ANT Con