KITA KP50E Series Manual
PR-0451F2022/04 Online Version We reserve the right to change the specification without prior notice.KITA SENSOR TECH. CO., LTD.www.kita.com.tw3 MPa 300 kPaRated pressure rangeSet pressure rangeWithstand pressureFluidPower supply voltageCurrent consumptionTemperature characteristicPort sizeLead wireWeight-0.100 ~ 2.00MPa0.000 ~ 2.00MPa10.0 ~ -101.3kPa0.0 ~ -101.3kPa-101.0 ~ 101.0kPa-100.0 ~ 100.0kPa-0.100 ~ 1.000MPa0.000 ~ 1.000MPakPakgf/cm 2barpsiinHgSet pressureresolution0.1MPa 0.0010.010.010.1───0.1──0.0010.0010.01Non-corrosive fluid SUS 316LSealed liquid Silicon oil12 to 24V DC ±10%, Ripple (P-P) 10% or less±0.3% F.S. ±1 digitIP65±3% F.S. of detected pressure (25°C) at temp. Range of 0~50°CØ4 Oil-resistance cable ( PVC ) - 26 AWG ( 0.15 mm 2 ) - 5 coresA. SPECIFICATIONS0 ~ 50°CApprox. 110g (Rear ported) ; Approx. 150g (Bottom ported)(Positive)Repeatability (Switch output)EnvironmentF1:R1/4", M5 ; F2:NPT1/4", #10-32 UNF ; F3: G1/4"(BSPP), M5F1C:Rc1/8"KP50EP- - (High)KP50EH- - (Vacuum)KP50EV- - (Compound)KP50EC- -Output typeMax. load currentMax. supply voltageResidual voltageResponse timeOutput short circuit protection Yes≤ 40mA (With no load)123456789Do not use corrosive fluid SUS316L, please confirm the specification in detailed.Please use within the rating pressure range. Do not apply pressure beyond recommended maximum withstand pressure, permanentdamage to the pressure sensor may occur.Do not drop, hit or allow excessive shock. Even if switch body appears undamaged, internal components may be broken and can causemalfunction.Turn power off before connecting wiring. Wrong wiring or short circuit will damage and/or cause malfunction.This product is not explosion-proof rated. Do not use in atmosphere containing flammable or explosive gases.Wiring for pressure sensor should avoid power source line and high voltage line. If use in the same circuit, noise may cause malfunction.The product is complied CE certificate, but no surge absorber. If required, please find other way to solve.Do not exceed the screw-in torque of 13.6 N.m when installing piping. Exceeding this value may cause malfunction.Sensors at end-of-life must be disposed of in accordance with E-Waste regulations of the country/region, NOT disposed of with regulargarbage.2 NPN or 2 PNP open collector125 mA≤ 1.5V30V DC (at NPN output), 24V DC (at PNP output)SwitchoutputLCD displaySwitch on indicatorUpdates timeIndicator accuracyEnclosureOperation ambient temp. rangeStorage ambient temp. rangeAmbient humidity rangeWithstand voltageInsulation resistanceVibrationShockOrange Indicator 1 : OUT1 & Orange Indicator 2 : OUT2± 2% F.S. ± 1 digit (ambient temperature: 25 ± 3°C)About 0.2sDisplay≤ 2.5ms (chattering-proof function: 25ms, 100ms, 250ms, 500ms, 1000ms and 1500ms selections)VoltageoutputCurrentoutputVoltageImpedanceCurrentImpedanceLinearity ±1% F.S.4~20mA ( ± 2.5%)Analogoutput35 ~ 85% RH (No condensation)-10 ~ 60°C (No condensation or freezing)250V AC in 1-min (between case and lead wire)50MΩ (at 500V DC, between case and lead wire)Total amplitude 1.5mm or 10G,10Hz-55Hz-10Hz scan for 1 minute, two hours each direction of X, Y and Z100m/s 2 (10G), 3 times each in direction of X, Y and Z0.001(~1.999)0.01(2.00~)0.01(~19.99)0.1(20.0~)0.01(~19.99)0.1(20.0~)0.1(~199.9)1(200~)KP50E SeriesFor your safety, please read the following before using.1~5V ( ± 2.5% F.S.)Max.Load Impedance: 250Ω at power supply of 12V600Ω at power supply of 24VMin.Load Impedance: 50ΩAbout 1kΩ3 ½ digital, 7 segment LCD display ( Red / Green / Orange ) ( Sampling rate : 5 times / sec. ) |
Related manuals for KITA KP50E Series
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine