Kenwood TH-F6A Quick Reference
Also see for TH-F6A: Instruction manualService manualInstruction manualSupplemental service manualService manual
Kenwood TH-F6A Quick ReferenceList of keys and their operationKey Number Function Shifted (ƒ)KeyFunction Hold (1 s)KeyFunctionLOW 1 Select current receiver transmission output power:H / L / ELBATT Display remaining battery capacityBAND 2 Select current receiver frequency band MODE Select receiving mode: FM / WFM / AM /LSB / USB / CWA/B 3 Select current receiver DUAL Select single or dual receiver operationƒ A (lock) Lock keysINFO 4 Recall information channel VISUAL Start visual scan of 5 frequencies on eitherside of current frequencyINFO Start Information channel scanSQL 5 Adjust squelch level for current receiver VOX Select VOX on / offBAL 6 Adjust volume balance between receivers PRI Start priority channel scanVFO B Select frequency manually M>V Copy memory frequency to VFO VFO Start band or program scanTONE 7 Turn repeater tone / CTCSS / DCS function on oroffT.SEL Select repeater tone / CTCSS / DCSfrequencyTONE (Tone on) Tone / CTCSS / DCSfrequency ID scanREV 8 Swap the transmit and receive frequencies SHIFT Select repeater transmit frequency offsetdirection: + or -REV Automatic Simplex CheckMN´f 9 Select display of memory name or frequency MN.IN Store name of current memory channelMR C Recall frequency from memory channel M.IN Store frequency into memory channel MR Start all memory channel scanMHz * Adjust VFO frequency MHz digits L.OUT Lock out scan of current memory channel MHz (VFO) Start MHz scan(MR) Start group scanFINE 0 Select fine tuning function on B Receiver onfrequencies below 470Mhz (LSB, USB, CW, & AM)STEP Select fine tuning frequency step: 33 / 100 /500 / 1000 HzENT # (VFO) Enter frequency digits(MR) Enter channel number (3 digits)(bell) Turn on tone alert for selected frequencyor memory channelCALL D Recall the Call channel for current frequency band C.IN Store current frequency into Call channelfor current frequency bandCALL Start alternating Call channeland current frequency scan1PTT Push To TalkLAMP Illuminate display for 5 seconds LAMP Illuminate display continuouslyMONI Pause scan / Disable squelch function while pressed MONI Select attenuator on / off for bothreceiversJoystick OperationKey FunctionMNU Enter Menu mode↑ (up) Scroll up (menu, freq., memory)Ø (down) Scroll down (menu, freq., memory)¨ (left) ESCape (cancel)Æ (right) OKMenu Function ListOn the Display Menu # Function Selections Default Ref. PageSCAN RESUME 1 Scan resume method TIME / CARRIER / SEEK TIME 27M.GRP LINK 2 Memory Group Link configuration 0 1 2 3 4 5 6 7 No Links 24MR METHOD 3 Memory Recall condition ALL BANDS / CURRENT BAND ALL BANDS 16PROG VFO 4 Programmable VFO frequency range (A receiver only) 39AUTO OFFSET 5 Auto Repeater Offset function ON / OFF ON 13OFFSET 6 Repeater offset frequency 0.00 ~ 59.95 MHZ in steps of 0.05 Mhz 12TUNE ENABLE 7 Permit use of the Tuning control when the keys are locked ON / OFF OFF 38TX INHIBIT 8 Inhibit the transmission ON / OFF OFF 40SP/MIC JACK 9 Select the SP/MIC jack function SP/MIC / TNC / PC SP/MIC 45, 46DTMF STORE 10 Store DTMF numbers in DTMF memories No Data 31DTMF SPD 11 DTMF tone transmission speed FAST / SLOW FAST 32DTMF HOLD 12 Hold the transmission for 2 seconds between DTMF key entries ON / OFF OFF 31DTMF PAUSE 13 The pause duration while transmitting DTMF tones 100 / 250 / 500 / 750 / 1000 / 1500 / 2000 ms 500 ms 32DTMF LOCK 14 Disable DTMF transmission with keys ON / OFF OFF 32PWR-ON MSG 15 Power-on message 8 characters HELLO !! 39CONTRAST 16 LCD display contrast 1 ~ 16 8 37BAT SAVER 17 Battery saver receiver shut-off period OFF / 0.2 / 0.4 / 0.6 / 0.8 / 1.0 / 2.0 / 3.0 / 4.0 / 5.0 sec. 1.0 sec. 37APO 18 Automatic Power Off function OFF / 30 / 60 min. 30 min. 36KEY BEEP 19 Beep function ON / OFF ON 37VOX on BUSY 20 Allow VOX transmission when the receiver is busy ON / OFF OFF 42VOX GAIN 21 Set the VOX gain sensitivity 0 (least) ~ 9 (most) 4 41VOX DELAY 22 Adjust the VOX delay time 250 / 500 / 750 / 1000 / 1500 / 2000 / 3000 ms 500 ms 41CALL KEY 23 Select a function for the CALL key CALL / 1750 Hz CALL 191750 HOLD 24 Hold the TX status when a 1750 Hz tone is transmitted ON / OFF OFF 13BEAT SHIFT 25 Shift the internal CPU clock frequency ON / OFF OFF 37BAR ANT 26 Enable the internal bar antenna below 10.1 MHz ENABLED / DISABLED ENABLED 34LANGUAGE 27 Select the menu language ENGLISH / JAPANESE ENGLISH 9PACKET 28 Select an external TNC packet speed 1200 / 9600 bps 1200 bps 45FM NARROW 29 FM narrow band operation ON (2.5kHz) / OFF (5kHz) OFF 39BATTERY 30 Select a battery type LITHIUM / ALKALINE LITHIUM 36RESET? 31 Select a reset mode NO / VFO RESET / MENU RESET / FULL RESET NO 501 If the Call channel is not available for the current operating frequency, an error beep sounds. |
Related manuals for Kenwood TH-F6A
Kenwood KIV-700 Quick Start Manual
Kenwood KMM-205 Quick Start Manual
Kenwood KMM-BT38 Quick Start Manual
Kenwood DDX6706S Quick Start Manual
Kenwood DMX4707S Quick Start Manual
Kenwood KMM-BT356 Quick Start Manual
Kenwood DPX305MBT Quick Start Manual
Kenwood DMX5020BTS Quick Start Manual
Kenwood KMM-BT732HD Quick Start Manual
Kenwood KDC-U7053BT Quick Start Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine