Key 7 SA840-A30 Installation Manual
Also see for SA840-A30: Installation manual
sa840_a30_inst_eng_400.docAll specifications are subject to change. For latest info check on www.keyseven.com.Having problems? Contact your dealer or visit ourhomepage www.keyseven.com.Select output formatOutput format selection is done during power-up.Connect wires a shown in below table, apply power, wait for buzzer acknowledgeand finish by disconnection power and the wires from below table.Wire connection for programming Formatno.Output formatYELW GREEN to VIOLET to WHITE nothing nothing 1 ABA (magstripe card)Deafault selectedYELLOW GREEN to VIOLET to nothing WHITE nothing 2 Wiegand26-bitYELLOW GREEN to VIOLET to nothing nothing WHITE 3 RS232, 9600,N,8,1Log functionYELLOW GREEN to VIOLET to PINK nothing nothing 4 MI Wiegand (26/8-bit)Like til Motorola/IndalaYELLOWl GREEN to VIOLET to PINK+WHT nothing nothing 5 UTFor use with Unitek, NOX Syst.YELLOW GREEN to VIOLET to PINK WHITE nothing 6 AVNGFor AlphaVisionNG/CP-508LCDYELLOW GREEN to VIOLET to PINK nothing WHITE 7 ATS WiegandYELLOW GREEN to VIOLET to nothing PINK nothing 8 COOPERFor RS central panelsYELLOW GREEN to VIOLET to WHITE PINK nothing 9 TAC WiegandFor I/Net SevenYELLOW GREEN to VIOLET to nothing WHITE GREEN 10 Castle (ver 4 eller nyere)For CS2600/2700/2800YELLOW GREEN to VIOLET to nothing PINK WHITE 11 TAC ABAFor til I/Net SevenProgramming sequence:1. Select output format and connect wires acordingly2. If protocol 6 then the tamper circuit can be disabled connecting theBROWN wire to ground now.3. Connect power4. Potocol 6/8/10 (Red LED flashes): Enter ID 1-8 or hold a randomprox up to the reader and wait for number of beeps according to IDno. If this is not done then ID=1 (Cooper) or ID=8 (AVNG).5. Await number of beeps according to format no.6. Disconnet power and wires.SA840-A30 is now programmet and ready for use. Programming is stored ininternal non-volatile memory of SA840-A30. Fascility code, if needed, can bechanged by use of KeyLink+ TECH PC program. If programming sequence needschangede then first follow below procedure forFactory reset.Factory reset1. Disconnect power2. Connect PINK wire to ground (BLACK)3. Wait 5 seconds until red LED flashes4. Disconnect the PINK wire within next 5 seconds5. Disconnect power.SA840 is now back in factory deafault state and a new protocol can be selected.MountingSA840 mounts with only 2 screws on flat building surface1 Mark the 4 drilling holes with thedrill guide and drill the holesaccording to the wall material.2 Fasten the nylon reflector.3 Guide the cable trough the hole inthe wall and fasten screws loosely.4 Connect SA840 wires appropriate and test tamper circuit with function 42 (Sabotagetest). Tighten screws.5 Clean key surface. Remove adhesive protection from front cover foil and place itcarefully on the SA850.SA840 is delivered with 3 meters of flexible14-core wire:Red 8-24V DCBack Ground. 0VGreen/White -Green/Brown -Yellow CLS (ABA), Data 0 (Wiegand) (open collector output)Green CCLK (ABA), Data 1 (Wiegand) (open collector output)Violet CDAT (ABA) (open collector output)Blue Tamper loop, wire 1Blue/Pink Tamper loop, wire 2Gray/Pink RS485 data, A (RS485)Grey RS485 data, B (RS485), TX (RS232)White LED indputPink Buzzer inputBrown Synchronizing. Only if two SA840’s are placed closer than 50cm to each other.Technical specificationsPower supply 8V to 24V DCCurrent consumption typical 80mATamper loop isolated, max100mA, 25 ohm, 50VOutput formats RS232 (9600,N,8,1) , RS485, Wiegand, ABA,UT, AVNG, TACWiegand facility code Programmable, default 7Network ID at delivery 1Prox reading distance up to 10 cm.Prox type 125kHz, auto-tuning, EM4102 compatibleDimensions (H-W-D) 0.59in-1.93in-0.59in (150mm-49mm-15mm)Weight 10.2oz (286g)Operating temperatures -30°F to 150°F (-35°C to 65°C)Operating humidity 0%-99%Wire 10’ (3 m), 14-leadSA840-A30INSTALLATIONS MANUALRev. 4.00• KEYPAD / PROX COMBO• MULTI PROTOKOL OUTPUT• SUITS MOST CONTROL PANELS• ALSO FOR OUTDOOR USE• SKAFOR approved in class 3This manual applies for serial no. greater than 1xx20000SA840-A30 emulates ABA mag. reader, Wiegand reader, RS232 and RS485SA840-A30 has a programmable facility code for Wiegand interfaceSA840-A30 interfaces directly to Alphatronics, Cooper, Castle and othersSA840-A30 is a molded weatherproof construction for outdoor useSA840-A30 has an optical tamper security circuitSA840-A30 LED’s and buzzer can be externally controlledSA840-A30 has electrical isolated output for tamper/sabotageSA840-A30 can be connected directly to PC or printerSA840-A30 can be part of a SA850-series networkSA840-A30 uses standard 125KHz EM4100-based prox cords / tagsSA840-A30 is SKAFOR approved in class 3 (AIA 212.069)All manuals and user guides at all-guides.com |
Related manuals for Key 7 SA840-A30
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine