LEDLITE LTFL50PIR Installation Sheet
50 WATT PIR LED Floodlight15-07-13Please read these instructions before commencing installationand retain them for future reference.Installation Sheet LTFL50PIR220-240V 50WIP44• Switch off the power source before installation.• Install a minimum distance of 1m away from ground.• The unit must be installed in the horizontal position (Figure 1a), not vertically (Figure 1b).SAFETY PRECAUTIONS1aHORIZONTAL1bVERTICAL1. If in doubt consult a professional electrician.2. Unscrew the floodlight from its wall bracket as indicated in Figure 2, part 4.3. Line up the wall bracket holes and drill three holes into the wall. Use appropriate size rawlplugs and screws to fix the bracket to the wall.4. Screw the floodlight on to its wall bracket and tighten firmly, angling the light as required.5. When connecting the power cable into the PIR sensor housing, please follow the wiringinstructions opposite.6. After connecting the power supply, the installation has been completed.Figure 1a & 1bINSTALLATION INSTRUCTIONSFigure 2CHOOSING A MOUNTING LOCATION• For the best results, fix your sensor on a solid surface, 1.8~2.5M above the ground.• For outdoor installation, a location under eaves is preferable.• Avoid aiming the motion sensor at pools, heating vents, air conditioners or objects that maychange temperature rapidly.• Do not allow sunlight to fall directly on the front of unit.• Try to avoid pointing the unit at trees or shrubs or where the motion of pets may be detected.• When choosing the mounting position consider that the sensor is more sensitive to motion acrossthe detection field (A) and less sensitive to motion directly towards the sensor (B) (Figure 3).• Select a location for the unit based on the coverage angles shown in Figure 4.1 2 34SENSORLESS SENSITIVESENSORMORE SENSITIVESENSITIVITY TO MOTIONFigure 3COVERAGE ANGLESFigure 4UNIT (M)WIRING INFORMATIONWired with threecore (w/o plug)240V Input (Figure 5)Brown = LiveBlue= NeutralGreen/Yellow = Earth240V Input Figure 5Walking TowardsWalking across12COVERAGE RANGELiveNeutralEarthPIRLNELNL'NLED FloodlightBrown = Live wire - LBlue = Neutral Wire - NGreen/Yellow = Earth wire - E• Pulse Override facility to enable lighting to be switched on for long periods using an existing switch.For pulse override switch the power OFF then ON again within 2 seconds to enable constant light.In constant light mode turn OFF and ON after 5 seconds to enable sensor mode.A B |
Related manuals for LEDLITE LTFL50PIR
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine