LaGrand COMBOGARD Pro Lock Instructions Manual
(P/N)732.018 Rev N 11/14 • © copyright 2009-2014 Kaba Mas LLCPage 1 of 3The ComboGard Pro Lock has three states of operation: FactoryDefault, Manual Setup , and Active . ComboGard Pro locks areshipped from LA GARD in Factory Default state without Users orfeatures enabled. Refer to the ComboGard Pro Setup Instructions(731.018) if Lock settings have not already been programmed.Factory Default: The Lock must be in the Factory Default state tobe programmed by the PC software.Factory mode functions as follows:• 1 key – When pressed, will open the Lock.• 0 key – When pressed, prompts the ComboGard Pro Setupsoftware to send the configuration settings to the Lock.OR if pressed and held, places the Lock into Manual Setup.• All other keys perform no function.Manual Setup: The Lock can be configured using the keypad only.Active: To activate the Lock and freeze the configuration, theManager combination MUST be changed.PROGRAMMABLE LOCK FEATURESMODES (Multiple Modes may be selected.)• Silent Alarm (Alarm Box Required - P/N 2789NC)If enabled, this option will send a signal to an outside alarmsystem through the LA GARD Alarm Box.• Dual ModeIf enabled, two combinations will be required to operate the Lock.The Manager and one additional User must be active.• Time Delay OverrideIf enabled, User 9 can override delay period.User 9 must be active.EXTERNAL SIGNALS (Alarm Box Required - P/N 2789NC. Onlyone External Signal type may be selected.)An external input signal to the Alarm Box will either disable the Lockfrom opening, override the time delay, or enable the remote overridedepending on the selection programmed for External Signals.• External Signal disables Lock opening with valid combination.• OR External Signal overrides Time Delay. (This option is ONLYavailable if enabled using Setup software.)• OR External Signal enables the Remote Override. (This optionis ONLY available if enabled using Setup software, and withLock code level 39E v1.09 or higher. )TIME DELAY• Delay Period 1 - 99 minutes• Open Period 1 - 19 minutesMANAGER INSTRUCTIONSCOMBOGARD PRO39E Electronic Combination LocksCOMBINATION LENGTHA combination length from six (6) to nine (9) digits may be selected.NOTE: To maintain the VdS Class 2 and EN 1300 Class Bcertification when the duress alarm feature is used, a combinationlength of 7 digits or longer must be selected.LOCK USERSSuper Master Reset - Resets Lock to Factory StateManager• Open Lock• Change Combination• Enable/Disable Users• Delete Users• Set Time Delay Values• Audit LockUp to 9 Users• Open Lock• Change CombinationSTANDARD LOCK FEATURESWrong Try Penalty• Entry of four (4) consecutive invalid combinations initiates a five(5) minute delay penalty.Lock responses during the penalty period are as follows:- The LED will flash every ten (10) seconds.- If any key is pressed, the Lock will flash the LED and beepthree times.• Once the penalty period has ended, two (2) consecutive invalidcombinations will initiate another five (5) minute penalty period.Low Battery Warning• Repeated audio/visual signals (LED flashes/beeps) during Lockopening indicate the battery is low and should bereplaced immediately.• If the battery level becomes too low to safely operate the Lock,pressing any key will initiate the low battery warning.The battery must be replaced before the Lock will operate.Audit Records• Lock records the last 63 events in non-volatile memory.• Audit file cannot be deleted from the Lock.• Only the Manager can audit the Lock.• ComboGard Pro auditing software and an Interface Adapter arerequired to retrieve a Lock audit.Dual-HandedSwing BoltDead Bolt 3750-KRound Entry3125Round EntryLOCKS ENTRY DEVICE OPTIONS8130(Optional)3190 Privat II(Optional)Kaba Mas LLCPage 1 of 2AUthorised dealer:T: 1300 764 971www ..safeguardsafes.com.ausales@safeguardgroup.com.au |
Related manuals for LaGrand COMBOGARD Pro Lock
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine