Larson Electronics EXP-RSP-FKWL-WLS-V1 Manual
EXP-RSP-FKWL-WLS-V1Larson Electronics, LLC Phone: (800) 369-6671 Fax: (903) 498-3364 www.larsonelectronics.com 1 of 3Rechargeable Hazardous Location Forklift Safety SystemFlashing LED Lamp, Siren - Remote SwitchThank you for purchasing the Larson Electronics EXP-RSP-FKWL-WLS-V1 Rechargeable Hazardous Location ForkliftSafety System. Follow the steps below for installing and maintaining the unit.WARNING: Do not attempt installation until you are familiar with all warnings, precautions, and proceduresoutlined within this instruction sheet.BEFORE INSTALLATION CONNECT FUSE INSIDE ENCLOSURE! THIS WILL ENABLE THEBATTERY FOR NORMAL OPERATION. SEE BELOW.In a Non-Hazardous environment:1. Locate the fuse shipped with your unit and place it aside.2. Remove cover bolts securing cover. Firmly grasp the right side of cover and carefullyswing open. Avoid striking cover or devices in cover or neighboring enclosures orstructures. There are 12 bolts securing the cover. This reveals the batteries and fuseholder.3. Install the fuse and check for operation by pressing each of the push buttons onthe switch. Pull each push button out to power off the unit.4. To close cover, make sure cover and body joint surfaces are clean and notscratched*. Swing cover shut. Cover/body bolt holes must match up. Hand startcorner bolts. Fully tighten all cover bolts. If cover bolts are damaged, only replacewith bolts provided by Larson Electronics.WARNING: CHANGE FUSES IN THE DE-ENERGIZED STATE ONLY OUTSIDE HAZARDOUS ENVIRONMENT.*INSPECT AND CLEAN THE MACHINED FLANGE (FLAM PATH) SURFACES OF BOTH THE COVER AND BOX. SURFACES MUST BE SMOOTH,FREE OF NICKS, SCRATCHES, DIRT OR ANY FOREIGN PARTICLE BUILD UP THAT WOULD PREVENT A PROPER SEAL. SURFACE MUSTSEAT FULLY AGAINST EACH OTHER TO PROVIDE A PROPER EXPLOSION-PROOF JOINT. CLEAN SURFACES BY WIPING WITH A CLEAN,LINT-FREE CLOTH.APPLY A LIGHT COAT OF LUBRICANT TO FLANGE SURFACES AND CLOSE THE COVER. INSTALL AND TIGHTEN ALL COVER BOLTS TO 30FT. LBS. MAKE CERTAIN THAT NO COVER BOLTS ARE OMITTED. USE ONLY THOSE BOLTS SUPPLIED WITH THE ENCLOSURE. CHECK THEBOLTED JOINT WITH A 0.0015” THICK FEELER GAUGE. THE GAUGE MUST NOT ENTER THE JOINT MORE THAN 1/8” AT ANY POINT.WARNING: MISSING BOLTS OR AN IMPROPER JOINT CAN RESULT IN AN EXPLOSION, CREATING APOTENTIAL FOR PHYSICAL INJURY OR PROPERTY DAMAGE.INSTALLATION PRECAUTIONS• Do not install fixture in any classified location where the marked operating temperature exceeds the ignitiontemperature of the hazardous atmospheres.• Consult fixture nameplate for the suitability ambient temperature shown on the nameplate.• Verify that the supply voltage agrees with fixture rating as indicated on nameplate.• All local and national electrical/building codes must be followed when installing this fixture. For codeinterpretation, consult your local authority.• Product must be intact.Before installing, make sure you are compliant with area classifications, failure to do so may result in bodilyinjury, death and property damage. Do not attempt installation until you are familiar with the followingprocedures. All installation must comply with the applicable Electrical Code. Make sure that the circuit is de-energized before starting installation or maintenance. |
Related manuals for Larson Electronics EXP-RSP-FKWL-WLS-V1
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine