24VAC/DC A+ B-GNDThe W-Modbus units have 24 VAC/VDC power in/out connection and con-nection for Modbus RTU communication via RS485.WARNING: When powering the W-Modbus device using 24 VAC, thepower supply/transformer should not be shared with another Modbus de-vice also sharing a RS485 connection. This is to avoid ground loops causedby the use of different types of rectification in the devices. W-Modbus usesfull wave rectification.Install the W-Modbus unit next to the device it should be connected to.APPLICATION AREAThe W-Modbus product transmits Modbus RTU frames wirelessly. It is de-signed to be used indoors as a Modbus RTU cable replacement.GENERALAll relevant personnel must acquaint themselves with these instructionsbefore installation. Warranty is subject to void if the product is not hand-led accordingly with the outlined instructions. Any damage to the productor parts due to improper handling will void the warranty. For additionalW-Modbus documentation scan the QR-code or visit www.lumenradio.comWARRANTYThe warranty or service agreement will be deemed void if:(1) The product is repaired, modified, or changed, unless such repair,modification or change has been approved by LumenRadio AB; or(2) The serial number on the product has been made ineligible or is missing.THE PACKAGING CONTAINS1 x W-Modbus or 1x W-Modbus PRO1 x Instruction leafletELECTRICAL SAFETYOnly qualified electricians or service personnel trained by LumenRadio mayperform interventions in connection with electrical installation. Always fol-low local/national rules when performing this type of electrical installation.When connecting a 24 V isolation transformer, this must be done in accor-dance with IEC 61558-1.TECHNICAL DATAPower supply: 24 VAC ±15% 50-60 Hz, 24 VDC ±15%Max. power consumption: 2.5 W24 V output max. power: 10 WAuto resettable fuse: YesCable rating, connector: solid / stranded0.14 - 0.5 mm2 / 0.2 - 0.5 mm2conductor sizes (AWG) 24 – 20by LumenRadioW-Modbuswww.lumenradio.comCopyright © LumenRadio AB 2022All Rights Reserved www.lumenradio.comFrequency band: 2.45 GHz, ISM band (2400-2483 MHz)Baud rate: 9600, 19200, 38400, 76800 bpsNumber of Nodes: 100 Nodes in one wireless networkNumber of hops: Max 8 hops in the meshing networkRange per hop: 500 m line of sight (approximately 50-70 m indoors with walls)Output (ERP): Max 20 dBmIP class: 40Material: ABS UL94-V0Colour: White, RAL 9003Ambient temperature: Operating: -20 to +55°CStorage: -30 to +80°CRH: 10 – 95% non-condensingWeight: 95gDimensions: W86.0 x H86.0 x D25.5 mmA W-Modbus network consists of a single W-Modbus Gateway connectedto the Modbus Client using an RS485 cable, and up to 100 W-Modbus No-des, each of them connected to one Modbus Server over RS485. Everydevice can act as either a Gateway or a Node, selectable by the 3 poleswitch - see Commissioning section.Each W-Modbus Node will scan to find the connected Modbus Servers’Modbus address. The scanning is done by querying each Modbus address,hence the process may take up to 2 minutes. If the W-Modbus Node cannotW-Modbus NodeModbus RTU cableWireless MeshW-Modbus PRO NodeW-Modbus GatewayClientServerServerServerServerServerServer Server Server ServerServerMANUAL W-Modbus and W-Modbus PRO LUMENRADIOScan for additionalinformationFCC ID: XRSTIMOMWAN201IC: 8879A-TIMOMWAN201MANUFACTURERLumenRadio ABSvangatan 2B416 68 GothenburgSwedenPOWER AND RS485 CONNECTIONINSTALLATIONSYSTEM OVERVIEWfind the connected Modbus Servers address, it will not be reachable by theModbus Client connected to the W-Modbus Gateway.If adding, removing or changing the Modbus address of the connected de-vice, double press the push button to initiate a new scanning.W-Modbus is an end device with internal termination resistor.With the PRO version of W-Modbus, up to four Modbus Servers can beconnected to one W-Modbus PRO Node - making it even easier to con-nect multiple devices located in close proximity to each other.W-Modbus and W-Modbus PRO are fully compatible and can be mixedin a system. All instructions below apply to both models.W-MODBUS PRO1. Confirm that the W-Modbus unit has no visible damage.2. The W-Modbus enclosure is wall mounted and fits onto a junctionbox. Start with mounting the backplate of the enclosure.3. Connect the power supply and the Modbus device to the W-Modbusunit, as shown to the right. Use the rear and/or top knockouts forcable entry.4. All W-Modbus units are factory set for Node operation, without theneed for additional configuration. If mixing serial configuration in thesystem, adjust the dip switches accordingly.5. Secure the front plate to the mounted back plate.6. Check that the W-Modbus unit and its wiring are securely mounted (ifthe unit is powered this will be indicated by the LEDs)The device is now ready for commissioning.The label on the back of the product shows the product type:W-Modbus or W-Modbus PRO. |
Related manuals for LumenRadio W-Modbus
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine