Malmbergs 99 190 21 Installation And Instruction Manual
1. Technical SpecificationsProduct type Independent PIR DALI sensor (Daylight harvest)Operating voltage 220~240VAC 50/60HzSwitched power Maximum 20pcs DALI devices Maximum 40mAPower consumption < 1WDetection angle 360oDetection area (DxH) 10 x 3m (Tangential)Mounting height 5m (Maximum)Detection range 10% / 50% / 75% / 100%Hold time 2s / 30s / 1min / 5min / 10min / 15min / 20min / 30minStand-by time 0s / 10s / 1min / 5min / 10min / 30min / 1h / +Stand-by dimming level 10% / 20% / 30% / 50%Daylight threshold 50 ~ 500Lux , DisableWarmming-up time 30sOperating temperature -20oC ~ +50o C3. Rotary Switch SettingsDetectionrangeChannel0123456789ABCDEF100%100%100%100%100%100%100%100%100%100%100%100%100%100%100%100%5s1min5min5min5min5min10min10min10min10min20min20min30min30min30min5s10s5min10min+∞+∞+∞30min+∞+∞+∞1h+∞+∞+∞+∞10s10%10%10%10%10%30%10%10%10%30%10%30%10%30%50%10%Disable50Lux50Lux75Lux100Lux200Lux50Lux75Lux100Lux200Lux100Lux200Lux100Lux200Lux400Lux100LuxHoldtime Stand-bytime Stand-bydimming level DaylightthresholdA rotary switch is built inside the sensor forscene selection / fast programming. Total16 channels available:Note: settings can also be changed by remote control 99 190 27. The last action controls.84. FunctionsDaylight sensor measures the available surrounding natural light, calculates how much electrical light isneeded to reach the total lux expected. The demand is given to the LED driver by DALI signal, so as todeliver the needed amount of electric light.4.1 Daylight Harvest (Daylight Regulating)The built-in daylight sensor can read ambient natural light and switch off the fixture automatically wheneverartificial light is not required (natural light lux level exceeds daylight threshold).Note: if the stand-by time is preset at "+∞", the fixture never switches off even when natural light issufficient.4.2 Lux Off FunctionFLUSH MOUNT PIR DALI SENSOR 99 190 21Installation and Instruction ManualRotary switch preset (Pleasesee the location in 2. Installation)Switch the power supply to the sensor two times within 2 seconds, the ambient lux level issampled and set as the new daylight threshold. Both the settings on rotary switch and theambient lux level sampled can overwrite each other. This feature enables the daylight sensorto be commissioned to the environment in which it is installed. The last adjustment remains inmemory.4.4 Ambient Daylight ThresholdBy connecting the “SYNC” terminals in parallel (see wiring diagram), no matter which sensordetects motion, all 99 190 21 in the group will turn on the lights when surrounding natural lightis below the daylight threshold. The sensor module is shared and the detection area could bewidely enlarged in this way.4.7 Synchronization Function2. InstallationWarnings:1. Installation of the sensor involves connecting it to the mains supply. This work must becarried out by a specialist in accordance with electrotechnical regulations.2. Disconnect supply before installing.Infrared receiverPhotocellLED indicatorPIRRotary switch preset1342(1) Sensor inset(2) Lens pluggable(3) Protection cover (covers thehigh-voltage terminals, and leavesthe DALI terminals exposed).(4) Ceiling (drill hole O 70mm).Turn off/on the power supply three times within 3 seconds, the light will be turned on for 8hours, even there is no motion detected, then go back to sensor mode automatically.Note: this 8H manual on mode can be cancelled by turning off/on the power supply one timewithin 1 second.4.5 8H Manual ON Mode For LED LampWith the help of push-switch, this sensor maybe over-ridden by the end-users to switch on/offthe lights manually, or adjust the light brightness during motion hold-time. This makes theproduct more user-friendly and offers more options to fit for extra-ordinary demands.* Short push (<1s): on/off function;ON OFF: the light turns off immediately and cannot be lighten for a certain time (equalsto hold time preset) even there is movement is detected. After this period, the sensor goesback to auto sensor mode.OFF ON: the light turns on 100% and goes to auto sensor mode, even when ambientLux level exceeds the daylight threshold.* Long push (>1s): adjust the target lux level by turning the light up or down. Both theadjustment on remote control and push switch can overwrite each other,the last adjustment remains in memory.* If no end-user adjustment is desired, simply leave this terminal disconnected.4.6 Manual Override420Light levelTime (hrs)Normal Electric LightDaylight controlled lightEnergy Saving ZoneNatural lightHold timeStand-by timeThe motion sensor is employed, but only activated on the manual press of the push switch,light keeps on in the presence, and dims down in the absence, and eventually switches offautomatically in the long absence.4.3 Semi-auto Function (Absence Detection)70mm64.7o85 68.173.356BlindNote: the blind can be plugged to the cover forreducing detection angle if necessaryVarning!Stäng av strömmen, ta ut säkringen på elcentralen eller ställ automatsäkringen till läge ”AV”,innan installationsarbetet påbörjas.Skall installeras av behörig installatör och i enlighet med gällande föreskrifter.www.malmbergs.com2017.03.01Art.no: 99 190 21 |
Related manuals for Malmbergs 99 190 21
Malmbergs 99 190 25 Installation And Instruction Manual
Malmbergs 99 190 22 Installation And Instruction Manual
Malmbergs Dual sense DALI 99 190 23 Installation And Instruction Manual
Malmbergs 99 190 17-18 Instruction Manual
Malmbergs 99 751 42 Instruction Manual
Malmbergs PAM21 Instruction Manual
Malmbergs E-2026 Instruction Manual
Malmbergs B620 Instruction Manual
Malmbergs B612Q Instruction Manual
Malmbergs ST-1002G Instruction Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine