IMPORTANTWATER LEVEL CHECK INSTALLATION NOTICEQ-0130, Q-0210, Q-0270, QM-45, QM-100Water Level CheckThe water float valve setting may change during shipping. Verify the water level is correct at initial startup.Check the water level while the ice machine is in the freeze cycle and the water pump is running. Thecorrect water level is 3/8″ (9.5mm) to 1/2" (12.7mm) below the top of the standpipe. A black line is presentto indicate the correct level. The water level is set correctly when water is slightly below or contacts theblack line during the freeze cycle. Use the following procedure to check the water level:Correct Water Level1. Verify the ice machine is level.2. Remove the siphon cap from the standpipe.3. Place the main ON/OFF/WASH toggle switch to the ON position and wait until the float valve stopsadding water.4. Observe the water level:• If the water level is correct, continue with step 5.• If the water level is incorrect, bend the float stem until the water level contacts or is slightlybelow the black line (3/8″ to 1/2" [9.5mm to 12.7mm] below the standpipe).5. Move the main ON/OFF/WASH toggle switch to the OFF position. The water level in the trough willrise above the standpipe and run down the drain.6. Replace the siphon cap on the standpipe and verify the water level and siphon action by repeating steps 3through 5.Set water level 3/8” to 1/2″(9.5 to 12.7 mm) below top ofstandpipe. Water must be slightlybelow or contacting the line.Siphon Cap1/2” (12.7mm)Standpipe3/8” (9.5mm) to