NA-DE 10220 Manual
Also see for 10220: Quick start guide
(d)(e)(f)(g)10220-10330 - 10440 - 10530CEILING ARMATURE WITH 360° MOTION SENSOR(e) Daylight settingThe sensor’s response threshold can be infinitely varied from 2-2000 lux.If you turn the knob clockwise device will operate at dark.Control dial set = daylight operation approx. 2000 lux.Control dial set = night-time operation approx. 2 lux.(f) Time settingLight ON time can be adjusted continuously from“10 sec. ± 1 sec. / 5 min. ± 10 sec.” If you turn the knob anticlockwise devicewill operate at minimum time. (10 seconds)Control dial set to - = Shortest time (10 sec. ± 1 sec.)Control dial set to + = Longest time (5 min. ± 10 sec.)NOTE: Device will automatically make its own offset by checking environmentfor approximately 5 minutes after the first installation. After this period device willoperate normally. If you think the device does not operate normal in first installation,please wait for 5 minutes and start to test again. Be sure that there is no motionby this period.DETECTING RANGESYSTEM COMPONENTS(a) Clamping washer(b) Glass Cover(c) Ceiling mount(d) Ceiling mount screw(e) Daylight setting nobe(f) Time setting nobe(g) Lamp holder (E27 porcelain)USAGE AREAS• At the building entrances, stair vestibules.• At the long halls within the flats.• At the places required within the flats.• At the parking garage.• At the requisite locations within the hotels.• At the schools, hospitals and oil filing station.GENERAL SECURITY CAUTIONS• Take off the original package and control if there is any damage of transportationand general view of the product.• Do not use the product at cross purposes.• Keep it away from water and moist areas.• Do not use the product at dusty, dirty and rusty places.• Do not supply high voltage.• Do not apply any liquid.• Protect from any stroke.• Using ~230-240V voltage is so dangerous that only the specialistelectricians must install and apply.CAUTIONS FOR INSTALLATION AND USAGE• Installing must be carried out professionally in accordance with applicable national wiringand electrical operating conditions.• Turn of the network before mounting.• Do not mount the product near the radiator and moist areas.• Place the product horizontal to the ceiling.• Fix the bulbs before operating.• Use 6A fuse the supply input.• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.• Setting can be made 10 - 15 second after the releasing of the power.• Time and daylight setting can be made during the day or night.• Do not change the time and daylight settings abruptly.• Do not make a second adjustment before you get a result from the first setting of the timeand daylight.• After you determine the right setting of the daylight, you can arrange the time as you need.• The best result for the daylight setting can be obtained by adjusting the minimum. And thatyou can find the correct setting for sensitivity incrementally.• When a cleaning needed for the glass, take of carefully and clean with a dry rag.• Avoid mounting the detector close to objects that can cause rapid temperature changessuch as heaters, fans, refrigerators and ovents etc, and prevent the detector from point-blank sunshine.• It can cause the device operate inaccurately if there is tree, brushes etc. in the coveragearea.• The product has Y type connection.“OFFERS ENERGY SAVING FEATURE’’SETTINGWalking targential to the sensor(normal detection range)Walking directly to the sensor(lower detection range)Figure 1TROUBLESHOOTINGMALFUNCTION CAUSE SOLUTION• Lamp is off• There is noelectricity on thedevice• Continuouslylamp is on• Change perceptionarea in device• Daylight adjustment set tonight-time mode during daytimeoperate• Bulb faulty or there is noconnection• Power switch off or no electricity• Fuse faulty• Fuse switch off or fuse faulty• Connection faulty.• Continuously movement indetection zone• Cars on the streets are beingdetected.• Wind, rain, snow is moving to thetrees & bushes or open windows indetection zone.• Sudden temperature changes dueto weather(wind, rain, snow) or theair expelled from fans.• Different ambient temperatures.• Control daylight setting andre-adjust• Fit the bulb into the lamp holder,if it still does not operate, changethe bulb.• Check the electricity and poweron.• Change the fuse.• Check the fuse if necessary usea new fuse.• Check the connection cables.• Check the detection zone.• Avert it is being detection.• Change detection zone, changesite of installation.• Change site of installation orkeep the reasons away.• Change site of installation.~230-240V / 50 Hz360°2.8 m.9 m.10 sec. ± 1 sec. / 5 min. ± 10 sec.Max 2x25W E27 bulbIP20 Class l ( 10530 class II )-20 °C ~ +40°CSPECIFICATIONS 10220-10330 - 10440-10530Operating voltageDetection angleMounting HeightDetection RangeTime settingsLighting loadProtection classOpr. temperatureDETECTION AREA :Detection area of motion sensors depends on the angle between PIR detector and movingdirection, temperature (power of lamps changes this temperature), mounting style and mountingplace. Temperature is very important for operation for motion sensor like all electronic devices.Using higher value of loads written on manuals and packages will decrease temprature insidethe device when using Ceiling Armatures with Motion Sensor. As a result detection range willdecrease and may cause defect of electronic components. Environment temperature will alsocause decrease of detection range. Detection range give is determined at +20°C. If the weatheris hot, it will decrease.The maximum detection range can be realized when walking tangential to the sensor (figure1)When walking directly to the sensor detection range will be low. Because you will not be ableto cut vertical areas. 10220-10330 - 10440 - 10530 Detection range of Motion Sensors is 9meters as diameter, 4,5 meters as radius.GUARANTYWe will remedy defects caused by material flaws or manufacturing faults. The warranty willbe met by repair or replacement at our own discretion. The warranty shall not cover damageto wear parts, damage or defects caused by improper treatment or maintenance. Furtherconsequential damage to other object is excluded.Claims under the warranty will only be accepted if the unit is sent fully assembled and wellpacked complete with a brief description of the fault, a receipt or invoice ( date of purchaseand dealer’s stamp) to the appropriate Service Center.(a) (b) (c)Neutral linePhase lineAs shown in figure, firstly open the string byturning counter clockwise and take off the glass.Mount the ceiling from places which shown infigure(c) and figure (d). And first will connectground connection, than connect connectoras shown in electrical connection part. Then laythe glass its place and fasten up the glass byconstricting the string.(L) = Line conductor(N) = Neutral conductor= GND conductorLamps must be connected before power is turned-ON.The sensing distance is provided according to the +20°C ambient conditions.ELECTRICAL CONNECTIONGBKK-10220_10330_10440_10530_130729_GLB_00Organize Deri Sanayi Bölgesi 12. Yol M1-8 Parsel 34953Tuzla / ‹STANBUL - TÜRK‹YEwww.na-de.com.tr • info@na-de.com.tr2.8 m.9 m.4,5 m.4,5 m.360°Complies with ROHS RegulationDirective 2002/95/EC |
Related manuals for NA-DE 10220
manualsdatabase
Your AI-powered manual search engine