NA-DE 15036 Instruction Manual
Also see for 15036: Instruction manual
TECHNICAL FEATURESOperating voltageBattery typeOperating battery timeCharging timeOperating modeProtection classOperating/Ambient temperatureRadiated Luminary(1 meter)~230-240 V / 50-60 Hz.3 units 1.2V 2100 mAH AA Ni-Mh rechargeable battery3 hours22 hoursnon-maintened (15036 with 36 LED - 16036 with 36 LED)maintened (15136 with 36 LED - 16136 with 36 LED)IP 20 class II-20 °C ~ +40 °C130 lumenProducer Company, Service station and spare parts suppling address:Na-de Elektronik Sanayi ve Ticaret A.fi. ‹stanbul Deri Organize Sanayi Bölgesi 12. Yol M1-8 Parsel34953 Tuzla /‹stanbul TÜRK‹YE Tel.:+90 (216) 394 01 55 -56 • +90 (216) 394 05 30 Fax: +90 (216) 394 01 64KK-15036xxx 140109_EN-00info@na-de.com.tr • www.na-de.com.trBatteries are out of warrantyGENERAL SECURITY CAUTIONS• Take out the product from orginal package and control if there is any damage of transportation andgeneral view of the product• Don't use the product for out of purpose• Keep away from the wather and moist areas• Keep away from dust and dirt• Protect from impact• Turn off the power before starting to install• For whole charging hold the battery in charge 22 hours continuous• Only authorized technicians must install the device• Only 1.2 V rechargable batteries must be used, otherwise dive is broken• Leave the battery recycling places after usingCAUTIONS FOR HUMAN HEALTH AND ENVIRONMENT• Do not try to repair the product by yourself• Keep away from stove, radiator or any heating device, do not expose to direct sunlight.• Don't try to mend product by opening the cover, call to our free call center.INFORMATIONS REGARDIN WRONG USAGE• Follow installation instructions as described in instruction manual, otherwise product is out of guarantee.• Keep the product away from dust, moisture, impact, fluid during the use. The product gets out ofguarantee if product defects occur as a result of those mentioned matters.INFROMATIONS REGARDING MAINTENANCE AND CLEANING THAT CAN BE DONE BY USER• When happens any defect you can get assistance from expert or our free call center.• Rechargable battery must be durable and must be changed periodicaly depending on using durationBefore changing batteries power must be cut. Battery compartment was shown in the figure 3 and 6.PERIODICAL MAINTENANCE• To extend life of batteries , batteries should be discharged in every 20 days.• Attendant of building should turn off the power, and wait for discharging of batteriesRULES FOR MAINTENANCE AND USAGE• When device gets dirty should be cleaned with a dry cloth.• Keep the product away from dust,moisture, impact, fluid during the use. The product gets out ofguarantee if product defects occur as a result of those mentioned matters.• When any defect happens, you must get assistance from an expert or our free call center.• Rechargable battery must be durable and must be changed periodicaly depending on using durationBefore changing batteries power must be cut. Battery compartment was showed in the figure 3 and 6.• Keep the original package, invoice, etc to use when its necesary.RULES FOR MOVING AND TRANSPORT• Should be carefull when transporting , Shouldn't put heavy goods on products, should be protectedfrom impact,dust,fluid.BASIC INFORMATION ABOUT PRODUCT FEATURES• Meets all necessities in the emergency lighting and directing solutions ,emergency lightings providesthe emergency security and prevents the panic in emergency.• Plain , stylish , quick mounting, easy maintenance.• Lights automatically when power cut and other type can light continuous and when power cut.• 130 lumen intensity of illumination at the emergency• 3 hours continuous lighting• Two colored LED shows state of battery, if charge is under 2,9 V lights red otherwise green• Spends less energy with LED• The product lifescycle: 10 years.MOUNTINGMODEL : 15036 with 36 LED, 15136 with 36 LEDFIGURE-1Remove the plastic screwcover with the screw driverand take off the behind screwsrelease the surface mountaparate from the device.FIGURE-2Fix the surface mountaparate on the wall.Screw the device in asurface mount aparateafter that fix the plasticscrew cover to the place BatterysocketFIGURE-3MOUNTINGMODEL : 16036 with 36 LED, 16136 with 36 LEDFIGURE-4Remove the plastic screwcover with the screw driver.FIGURE-5Mount the device with 2 screwson the wall or ceiling.Fix the plastic screw coverto the placesBattery socketFIGURE-6FIGURE-7N :NotrL : Line (Phase)ELECTRICAL CONNECTION OF THE DEVICEL N~230-240 V / 50-60 Hz.USAGE AREAS• At the hospitals, flats, houses• At the schools• At the supermarkets, shops and covered markets• At the stations, terminals, airports and ports• At the spare foundations places of worship andsport complex• At the museums and exhibition galleries.• At the accommodetions for travelers andrestaurants• At the place of amusementINSTRUCTION MANUAL15036 with 36 LED, 15136 with 36 LED,16036 with 36 LED, 16136 with 36 LEDEMERGENCY LIGHTING ARMATURESComplies with ROHS Regulation Directive2002/95/ECTS EN 60598-1TS EN 60598-2-22 AN 60041383 000127111002 002TÜVRheinlandR |
Related manuals for NA-DE 15036
manualsdatabase
Your AI-powered manual search engine