NIVELCO THERMOCOUNT TXP 1 Series User Manual
txp171en22h03 ▪ 1 / 2Thank you for choosing a NIVELCO instrument.1. APPLICATIONTHERMOCONT TXP resistance thermometers with a drilled thermo-well case are used as temperaturemeasurement sensors in industrial process control, especially in the gas industry. The temperature sensorsare suitable for temperature measurement of various gaseous media inside pipelines, tanks, and furnaces.The heat-sink on the outer protective tube provides accurate measurement independently from the ambienttemperature. The double pipe construction - including the inner and outer tube and well - meets themechanical and vibrational protection requirements. Process connection and electrical connection areprovided as detailed below. The cable glands provide sealing for the cables.The outer protective tube is a drilled thermo-well case made from stainless steel. The cover of the housinghas a chain to prevent misplacing it. The Pt100 temperature sensor can be replaced without removing theinstrument from the process.2. TECHNICAL DATATXP–1– TXP–4– TXP–7–SensorAccuracy class Pt100A, class “A” (MSZ EN 60751), as per order codeType single, 2-wire dual, 3-wire single, 4-wireMaterial of internal protectivetube PTFEProcess connection Spring loadedVersion Ground-independentHousingHousing material Powder-coated aluminum (EN AC – 43100)Cable gland M20×1.5 or without cable glands, ½" NPT interior threadCableFor Ex ia protection type: nickel-plated brass cable gland, or closing bolt;For Ex d and Ex dia protection types:Ex d IIC certified cable gland for cable Ø6…Ø12 mm (Ø.236…Ø.472")Electrical connection Screw type terminalIngress protection IP67Probe Process connection M33x2, 1″ NPTMaterial 1.4571 stainless steelInsertion length max. 500 mm (19.7″), as per order codesProcess pressure Max. 80 bar (8 MPa / 1160 psi)Measuring range –50…+150 °C (−58…+302 °F)Ambient temperature –30…+80 °C (−22…+176 °F)Electrical protection Class IIIEx markingII 1 G Ex ia IIB T6…T4 GaII 2 G Ex d IIB T6…T4 GbII 1/2 G Ex d ia IIB T6…T4 Ga/GbEx Information U i: 30 V, I i: 140 mA, P i: 1,1W, C o = 0, L o = 02.1 EX TEMPERATURE CLASSIFICATIONTemperature class T6 T5 T4Max. ambient temperature +65 °C (+149 °F) +70 °C (+158 °F) +70 °C (+158 °F)Max. medium temperature +85 °C (+185 °F) +100 °C (+212 °F) +135 °C (+275 °F)2.2 A CCESSORIES User’s Manual Warranty Card EU Declaration of Conformity2.3 O RDER CODESTHERMOCONT T X P – – Ex (1)P ROCESS CONNECTION C ODE S ENSOR TYPE / P T100C LASS “A” C ODE P ROBE LENGTH C ODE E X CERTIFICATE C ODE1" NPT 1 Single, 2-wire 1 120 mm 0 None 0M33x2 V Dual, 3-wire 4 160 mm 1 Ex d ia IIB / ½″ NPT(2) 6Single, 4-wire 7 200 mm 2 Ex ia IIB 7250 mm 3 Ex d ia IIB 8(1) The order code of the Ex-version ends in “Ex” 300 mm 4 Ex d IIB 9(2) Without cable glands, use glands with protection designation "d" only 350 mm 5400 mm 6450 mm 7500 mm 8 |
Related manuals for NIVELCO THERMOCOUNT TXP 1 Series
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine