NSI TORK TPX Series Manual
MODEL#: TPX100, TPX100S, TPX300, TPX300S, TPX600, TPX600SATTENTION: Read carefully before attempting to install this transformer. Refer to unit inside labelfor wiring example. Failure to comply with instructions could result in personal injury and/orproperty damage!1. Read and follow all instructions.2. Do not sumberge transformer.3. Do not connect two or more transformers in parallel or use with dimmers.4. This transformer must be installed by a qualified electrician in accordance with the National Electrical Code (including article 680) or Ca-nadian Electrical Code (including section 68) and local code requirements. For Canadian installations, supply circuit must be protected by aground fault circuit interruptor.5. If transformer is used for direct connection of underwater lights, refer to NEC 680.23, 680.24 or CEC 68-060, 062 & 066 for further details.6. Do not install this equipment within 5 feet (Canada: 3 meters) of any body of water. USE COPPER CONDUCTORS ONLY.7. Do not exceed the maximum ratings of individual components, wiring devices and current carrying capacity of conductors.8. For grounding and bonding this transformer & the installation, refer to NEC section 680 or CEC section 68.9. Not for use in dwelling units.10. For outdoor use only.11. Mount brackets and hardware supplied for installation.The TPX series Transformers are specifically designed to supply 12 volts to outdoor garden lights, pool/spa lights and submersible fixtures. Theyinclude a ground shield between the primary and secondary windings to ensure safe operation and the built-in circuit protection will disconnectpower to the transformer in case of defect or overload. These transformers are suitable for direct connection to underwater Pool and Spa lights.The enclosure of the transformer must be provided with a fail-proof ground as required by NEC Article 680 and any applicable local codes. ForCanadian installations, the supply circuit must be protected by a ground fault circuit interruptor.The transformer should be mounted at least 1 foot above the deck level with the field wiring compartment down.Make sure that all unused tops/leads are separately insulated. Use the following tables as a guide to determine correct wire size:TPX SERIESLOW VOLTAGE POOL AND SPA TRANSFORMERSLOW VOLTAGE POOL/SPA TRANSFORMERS FORPOOL/FOUNTAIN/OUTDOOR LIGHTINGELECTRICAL RATINGS: TPX100/TPX100STPX300/TPX300STPX600/TPX600SINPUT: 120VAC, OUTPUT: 100W, 12V, 13VINPUT: 120VAC, OUTPUT: 300W, 12V, 13V, 14VINPUT: 120VAC, OUTPUT: (2) 300W outputs, 12V, 13V, 14VDESCRIPTION:ONE YEAR LIMITED WARRANTY: If this product fails because of a manufacturing defect within one year after purchase, we will, at our option, either repair or replace it at no charge. Our warranty does not cover damagecaused by accident, abuse or misuse. We assume no further liability with respect to the sale or use of this product. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THEWARRANTY OF MERCHANTABILITY. We make no warranty with respect to the fitness of any goods for the users particular application. This warranty gives you specific legal rights, and you may also have other rightswhich vary from state to state.It is our intent to provide accurate and current specification information. However, in the interest of product improvement, TORK may alter the specifications or constructional details without prior notice.! IMPORTANT SAFETY INSTRUCTIONS ! SAVE THESE INSTRUCTIONSINSTALLATION AND INFORMATIONWattage50-100100-149150-199200-249250-30012 VOLT TERMINAL14Ga.8’6’N/AN/AN/A12Ga.12’9’7’N/AN/A10Ga.20’15’12’9’8’8Ga.31’23’18’14’12’6Ga.49’36’27’21’18’13 VOLT TERMINAL14Ga.32’25’N/AN/AN/A12Ga.50’39’30’24’N/A10Ga.82’65’49’39’32’8Ga.125’98’73’60’49’6Ga.195’153’115’93’77’14 VOLT TERMINAL14Ga.53’42’32’N/AN/A12Ga.83’65’49’39’N/A10Ga.136’107’80’64’57’8Ga.207’163’122’98’87’6Ga.324’254’191’152’136’TPX100TPX100STPX300TPX300STPX600TPX600SDESCRIPTION:Gray SteelStainless SteelGray SteelStainless SteelGray SteelStainless SteelDIMENSIONS: H x W x D7.2 x 5.1 x 4.2 in.10.4 x 7.3 x 4.2 in.KNOCKOUTS:All models have multiple 1/2” and 3/4”combo KOs located on bottom, sides ofenclosure.WARNINGPREVENT ELECTROCUTION : ÉVITEZ L’ÉLECTROCUTIONDISCONNECT ALL SUPPLY CONNECTIONS BEFORE SERVICING.DÉBRANCHEZ L’ALIMENTATION ÉLECTRIQUE AVANT DE PROCÉDER ÀL’ENTRETIEN OU À UNE RÉPARATION.MODEL:LI-1013(B) 888.500.4598 • www.nsiindustries.com |
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine