Nidec-Shimpo FG-3006 Operation Manual
Also see for FG-3003: Operation manualsOperation manual
The new FG-3000 Series digital force gauges are thechoice for simple, cost-effective tension and compres-sion testing.Combining one of the most compact hous-ings, yet maintaining a large back-lit LCD, these unitswere designed to fit perfectly in the hand for ease ofuse. The multi-language FG-3000’s provide menu pro-gramming for intuitive set-up of the instrument to yourdesired requirements. Three modes of operation areselectable: Track mode displays live readings, Peakmode records the maximum reading sensed during thetest, and Pre-set mode which activates user definedhigh and low limit set points. The programmable lim-its provide a quick visual and audible indication if atest passes or fails. In addition, a comparator outputenables integration of the instrument into your qual-ity system for repetitive testing such as on productionlines.The display graphics facilitate user comprehensionand operation. An analog bar graph provides perspec-tive of current reading in comparison to the full scalerange. Pass/Fail icons provide an instant response ofthe testing outcome while a storage symbol acknowl-edges when a reading is logged. A menu-selectabledisplay orientation streamlines switching from push topull testing for portable or test stand applications.FG-3000 Digital Force GaugeOperation ManualOperators should wear protection such as a mask and gloves in casepieces or components break away from the unit under test.Whether the unit is ON or OFF, DO NOT exceed the capacity of thegauge. NEVER exceed 150% of the rated capacity, or the load cell willbe damaged. At 110% of the rated capacity, the display will flash awarning.When mounting FG-3000 Series Digital Force Gauges, use M4 mount-ing screws with a maximum insertion depth of 7 mm into the gauge.Hand tighten mounting screws, DO NOT use tools. Do not use damagedclamp.Measure in line tension and compression forces only. DO NOT attemptto measure forces at an angle to the measuring shaft – damage to loadcell and/or shaft may result.Do not attempt to repair or alter this instrument. Warranty will be voidedand damage to the unit may result.Use and store within the stated temperature and humidity ranges, ordamage and failure may result.When using adapter measuring heads, do not use tools. Hand tightenonly.SPECIFICATIONSAccuracy: ± 0.3% F.S.Selectable Units: N, kgf, ozf, and lbf. (Depending on Range)Overload Capacity: 150% of F.S. (LCD flashes beyond 110% ofF.S.)Measurement Method: Peak, Track, PresetData Sampling Rate: 1000 HzDisplay: 160*128 dot matrix LCD with BacklightDisplay Update Rate: 10 times/secondResolution: (See chart)Memory: 500 dataSet Point: Programmable high and low limits in Preset ModeBattery Indicator: Display flashes battery icon when battery islowPower: 3.6VDC 800mAH Ni-MH rechargeable batteriesBattery Life: Approximately 16 hours continuous use per fullchargeCharger / Adaptor: Universal USB/BM charger, Input: 110 ~240VACTemperature Effects: <0.054% per °F (0.03% FS per °C)Outputs: USB, RS-232; High & Low Limit NPN’sOperating Temperature: 14 to 104°F (-10 to 40°C)Storage Relative Humidity: 20 to 80%Housing: AluminumStorage Temperature: -4 to 122°F (-20 to 50°C)Oper. Relative Humidity: 5 to 95%Dimensions: 5.5 x 2.8 x 1.4” (140 x 71 x 35.5 mm)Product Weight: 0.9 lb (0.4 kg)Package Weight: 2.25 lb (1 kg)Warranty: 1 yearCertification: CEIncluded Accessories: AC Adaptor/Charger, USB cable, cali-bration cert., 6 attachments: hook, flat tip, conical tip, chisel tip,notched tip, extension shaft.14356710 892LCD Screen1. Battery icon: Battery level or charging status. Flashes whengauge needs to be recharged.2. OK/OV Indicator: Measured value between low limitand upper limit; Value over upper limitValue between lower limit and 75% of lower limit3. Force icon: Indicates force direction. TensionCompression4. Test mode icon: Three measurement modes: Track, Peakand Preset5. Current meaured value6. Analog bar: Indicates current position within full scale. Whenthe bar enters the area enclosed by the dotted line, it meansfull scale capacity is exceeded and overload.7. Storage icon: Indicates data is being saved.8. System time9. Units Indicator: Selected engineering unit.10. Data Transmission icon |
Related manuals for Nidec-Shimpo FG-3003
Nidec-Shimpo FG-3000R Operation Manual
Nidec-Shimpo FG-3000 Operation Manuals
Nidec-Shimpo FG-7009 Operation Manual
Nidec-Shimpo FG-7000 Operation Manual
Nidec-Shimpo FG-7000T Operation Manual
Nidec-Shimpo FGE-0.5XY Operation Manual
Nidec-Shimpo FGE-HXY Series Operation Manual
Nidec-Shimpo DT-200LR Operation Manual
Nidec-Shimpo PT-110 Operation Manuals
Nidec-Shimpo SMT-200CL Operation Manuals
manualsdatabase
Your AI-powered manual search engine