Niigata seiki EOM133 Series Instruction Manual
Also see for EOM133 Series: Instruction manual
SR44ON/OFFSET0045405303540ON/OFFSETABS25 30 3045405ON/OFFSET004540530354025ON/OFFSET0 5 1045405ON/OFFSET045405ON/OFFSETABS045405ON/OFFSETABS045405DIGITAL OUTSIDE MICROMETERNiigata seiki Co., Ltd.5-3-14, Tsukanome, Sanjo, Niigata, Japan, 955-0055Tel. : +81-256-33-5522 Fax. : +81-256-33-5518MAIL intl.sales@niigataseiki.co.jpURL http://www.niigataseiki.co.jpClean measuring surfaceswith cloth.Confirm 0-Point setting andre-zero with long press of[SET] Button (> 2 sec.)Cycle power by removingand replacing battery.Replace battery with newone.Measured value iswrong.PRECISION OUTSIDE MEASURING INSTRUMENTEOM133-***ModelNo.INSTRUCTION MANUALThank you for purchasing the Niigata Seiki DIGITAL OUTSIDE MICROMETER.This precision gauge measures outside dimension of object placed between the Anvil and Spindle.For safe and proper use of this product, please read this instruction manual before use and follow the procedures described.Please keep manual where it is accessible to user for future reference.Keep this manual with the instrument if transferred or leased to a third party.For inquiries about this product, please contact dealer or Niigata Seiki at the address listed on the following page.PARTIDENTIFICATIONSPECIFICATIONS FEATURESTROUBLESHOOTINGWeightg26538046060051556046Accuracyμ mMeas. Rangemm0 2525 5050 7575 100100 125125 150Model No.EOM133 -25EOM133 -50EOM133 -75EOM133 -100EOM133 -125EOM133 -150Resolution 0.001mmPower SR44 (Silver Oxide Battery)Ratchet stop.Carbide measuring surfaces.Spherical Anvil Attachment (SR2.5) included.Auto-display-off function (approx. 6 minutes.)SR44 (silver oxide battery) included for testing.Insulating cover Thermal shieldSAFETY PLEASE OBSERVEAlways follow the procedures specified below in order to prevent harmto yourself or others, and to prevent damage to property.Indicates risk of personal injury or propertydamage if not followed.CAUTIONAlways clean measuring surfaces with soft cloth before use.Do not turn spindle more than 3mm above uppermeasurement range.This is a precision instrument, handle with care. Do notdrop or subject to excessive forces.Keep away form high voltage and strong magnetic fields.Instrument damage may result.Keep instrument away from direct sunlight or hightemperatures such as in a car, or near a stove or heat source.Do not disassemble or modify.Please do not use organic solvents to clean the body ofthe instrument.When not being used for long period of time, pleaseremove battery.Only use as directed. Improper use may cause accident or injury.Not incl. quantization error (±1 count)ClampSpindleAnvilFixed Side0-PointAdj. HoleFrameInsulatingCover[ON/OFF] Button,[SET] ButtonLCD DisplayMeas. Surfaces SleeveThimbleRatchet StopCarbide TipsBatteryCoverSpherical (Ball)AttachmentREAR FRONTACCS.SpannerCalibration Std.Not w/ EOM133-25SR44 Silver Oxide CellFor TestThe gauge is now ready to take measurements.EOM133-25 0.000 EOM133-50 25.000EOM133-75 50.000 EOM133-10075.000EOM133-125 100.000 EOM133-150125.000SETTING THE ZERO-POINTBATTERY OPERATION BALL ANVIL① Remove any grease or dust from the measuring surfacesusing a clean cloth, such as lens cleaning cloth. Make sureno foreign objects are adhered to the measuring surfaces.② Place object to be measured between the Anvil and Spindle.③ With the Thimble Clamp loose, turn the Thimble to capturethe measured object between the measuring surfaces.Stop after 1~3 “Clicks” from the Ratchet Stop. (Fig. 5)④ The measured value is displayed on the LCD display.※ Measurement can also be read off Thimble and Sleeve aswith a standard micrometer.POWERThe Spherical (Ball) Anvil Attachment can be attachedas required.After mounting, please set 0-Point following the procedure“Setting the Zero-Point” above.CAREMeas. surfaces touchPress for > 2 sec.Match origin linesRotate until origins matchWhen the Spherical Attachment is attached, the measurementindicated on the Sleeve scale will read 5mm larger thanactual size. (Fig. 6)If any cutting fluid or moisture gets on the instrument body, wipeusing a soft dry cloth to prevent corrosion.After use, remove any cutting chips or contamination using a softcloth and apply rust preventative oil. Keep out of reach of children.Fig.3LockLoosenFig. 4Fig.5Fig.6Fig.2Fig.1① Remove any grease or dust from the measuring surfacesusing a clean cloth, such as a lens cleaning cloth. Make sureno foreign matter is adhered to the measuring surfaces.② With Spindle Clamp loose, turn until measuring surfacestouch. Turn until Ratchet Stop clicks 1~3 times. (Fig. 1)※ For models other than EOM133-25, please insert thesupplied Calibration Standard between measuring surfaces.③ To align the Thimble Scale 0-Point reference lines. (Fig. 2)1. Tighten Spindle Clamp to lock Spindle.2. Insert the spanner into 0-point Adjustment Hole on rearof Thimble.3. Use spanner to rotate Sleeve to align the 0-Point lines. (Fig. 3)④ Press the [SET] Button for more than two seconds. (Fig. 4)LCD will display “SET” for 0.5 seconds, and then thedisplay will read as shown below:"Click Click"RatchetStopClampWorkpieceSleeve reading = Meas. + 5mmSpherical Attachment[SET] ButtonSpannerThimbleRatchetStopBatteryCover① Rotate the Battery Cover on rearusing coin or similar tool.② Insert battery with “+” side up.③ Replace Battery Cover.When [ON/OFF] Button is pressed, power is turned ON, andmeasurement is displayed on the LCD.Press [ON/OFF] Button a second time to turn power OFF.Setting the origin used for measurements.Once set, even when power is off the origin is saved anddoes not have to be reset with each use.When battery is replaced origin will go to default setting,please reset.Make sure the Battery Cover is closedsecurely. Please make sure the gasket isin the proper place on the Battery Cover.Only use SR44 typebattery.CAUTIONOpenERROR CORRECTIVE ACTIONLCD does not display.Displayed value isunstable.Display is not clear.If problem persists, or if you have any questions, please conta ctdistributor or place of purchase.Please note, manufacturer is unable to respond to inquires or provideservice directly. Please contact distributor or place of purchase.EOM133-125EOM133-150No Insulating CoverThermalShield"Click Click"All manuals and user guides at all-guides.com |
Related manuals for Niigata seiki EOM133 Series
Niigata seiki EOM133 Series Instruction Manual
Niigata seiki S Series Instruction Manual
Niigata seiki SCG Series Instruction Manual
Niigata seiki ALD Series Instruction Manual
Niigata seiki GVC Series Instruction Manual
Niigata seiki MCA S Series Instruction Manual
Niigata seiki GDG Series Instruction Manual
Niigata seiki SCDI S Series Instruction Manual
Niigata seiki QEM394 Series Instruction Manual
Niigata seiki QEM394 Series Instruction Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine